VMWARE-NSX-MANAGER-MIB :: vmwNsxMEdgeAntiAffinityRuleViolated

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMEdgeAntiAffinityRuleViolated

vmwNsxMEdgeAntiAffinityRuleViolated

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeAntiAffinityRuleViolated

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.4.0.19

Node type: NOTIFICATION-TYPE

Description: A notification generated when powering on NSX Edge appliance violates a virtual machine anti-affinity rule. Action required: Anti affinity rules removed from cluster. Both HA VM may run on same host. Go to VC and please revisit anti affinity rules on Cluster

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeAntiAffinityRuleViolated
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.4.0.19

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:59128->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (486700280) 56 days, 7:56:42.80
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeAntiAffinityRuleViolated

SNMPv3 example:

snmptrap -v3 -l authPriv -u snmpv3user -a SHA -A "AuthPass1" -x AES -X "PrivPass1" <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeAntiAffinityRuleViolated

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeAntiAffinityRuleViolated OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.4vmwNsxMEdgeVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.4.0vmwNsxMEdgePrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.4.0.19vmwNsxMEdgeAntiAffinityRuleViolatedVMWARE-NSX-MANAGER-MIB