VMWARE-NSX-MANAGER-MIB :: vmwNsxMVxlanOverlayClassMissingOnDvs

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMVxlanOverlayClassMissingOnDvs

vmwNsxMVxlanOverlayClassMissingOnDvs

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanOverlayClassMissingOnDvs

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.20.0.9

Node type: NOTIFICATION-TYPE

Description: NSX packages where not installed prior to DVS configuration for VXLAN. All VXLAN ports will fail to connect until resolved. Action required: See KB 2107951 https://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=2107951&sliceId=1&docTypeID=DT_KB_1_1&dialogID=40732862&stateId=0%200%2040754197 Frequency of traps: Once per setting of the com.vmware.netoverlay.layer0=vxlan opaque property or whenver the host is configured for vxlan or Host reconnects to VCEnter and host has some problem. Affects: VXLAN Traffic for that Host will be affected.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanOverlayClassMissingOnDvs
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.20.0.9

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:52302->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (35377742) 4 days, 2:16:17.42
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanOverlayClassMissingOnDvs

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanOverlayClassMissingOnDvs OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20vmwNsxMVxlanVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20.0vmwNsxMVxlanPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20.0.9vmwNsxMVxlanOverlayClassMissingOnDvsVMWARE-NSX-MANAGER-MIB