All MIBs › OMNI-gx2EM-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 EM expansion module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2EM-MIB?
OMNI-gx2EM-MIB is a Cisco/Scientific-Atlanta proprietary SNMP module for the GX2 EM expansion module, a hardware add-on used in hybrid fiber-coaxial (HFC) optical nodes within cable broadband access networks. As an expansion-module-specific MIB, it is expected to expose module identity, slot occupancy, and hardware operating parameters rather than protocol or traffic statistics. Its primary value is in monitoring the physical health of the expansion module itself, such as module presence/insertion state, power supply condition, and operating temperature within the optical node enclosure, which are critical to preventing unplanned outages in outside-plant equipment. It likely fits into the broader Scientific-Atlanta/Cisco OMNI optical node MIB family and may share naming or indexing conventions with related node-management MIBs, though no module description or object list was available to confirm specifics. It would typically be deployed by cable/MSO operators using centralized network management systems to poll remote HFC nodes for hardware-level fault conditions. Network engineers evaluating or troubleshooting this functionality can download the OMNI-gx2EM-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2EM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module)
Monitoring Examples
No module description or sample objects were captured for this MIB in the source, so specific object names cannot be confirmed from the available metadata. Based on the 'EM' (expansion module) naming convention and its HFC optical node context, a monitoring scenario would likely involve polling a per-slot hardware status object to detect module removal, power loss, or over-temperature conditions in the node. This explanation is therefore provisional and should be verified against the actual MIB source before being relied upon for object-level polling.
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Em1000 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapEMConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.30.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEMConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.30.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEMRFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.3 | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMRFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.4 | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMRFOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.5 | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMOpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.6 | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMLaserBiasAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.7 | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMLaserTempAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.8 | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMTECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.9 | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.10 | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEM12vAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.11 | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEMModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.12 | This trap is issued when the Laser Module Temperature goes out of range. | ||
| NTF trapEMFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.13 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapEMLaserBiasCntLoopAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.14 | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| NTF trapEMBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.15 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapEMLaserBiasCntLoopInitAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.16 | This trap is issued when the Laser Bias Control loop init fails. | ||
| NTF trapEMRFParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.17 | This trap is issued when the RF parameter Init fails. | ||
| NTF trapEMTECParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.18 | This trap is issued when the TEC Parameter Init fails. | ||
| NTF trapEMAttnTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.19 | This trap is issued when the Attenuator Table Init fails. | ||
| NTF trapEMPowerMeterTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.20 | This trap is issued when the Power Meter Table Init fails. | ||
| NTF trapEMLaserDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.21 | This trap is issued when the Laser Data CRC is incorrect. | ||
| NTF trapEMAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.22 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapEMFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.23 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapEMUserRFOffAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.24 | This trap is issued when the the User RF is turned off. | ||
| NTF trapEMUserOpticalOffAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.25 | This trap is issued when the User Optical Power is turned off. | ||
| NTF trapEMResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.30.0.26 | This trap is issued when the Factory Default Reset occurs. | ||
| gx2emDescriptor | 1.3.6.1.4.1.1166.6.1.2.30.1 | |||
| gx2emAnalogTable | 1.3.6.1.4.1.1166.6.1.2.30.2 | not-accessible | This table contains gx2Em specific parameters with nominal and current values. | |
| gx2emAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.30.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2emAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.30.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Offset Monitor Analog parameter. |
| STR uomOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| FLO majorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO minorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO currentValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.8 | Float | read-only | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| INT stateFlagOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO minValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.10 | Float | read-only | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| FLO maxValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.11 | Float | read-only | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| INT alarmStateOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.30.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| STR labelOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| STR uomOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.14 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| FLO majorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO majorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO minorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.19 | Float | read-write | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO minValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.21 | Float | read-only | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.22 | Float | read-only | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| STR labelRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Attenuator Setting Analog parameter. |
| STR uomRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. |
| FLO majorHighRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.30 | Float | read-write | The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.32 | Float | read-only | The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.33 | Float | read-only | The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.30.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter. |
| STR labelOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR uomOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO majorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.41 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValueOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.43 | Float | read-only | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.44 | Float | read-only | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.30.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR labelLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR uomLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| FLO majorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.52 | Float | read-only | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.54 | Float | read-only | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.55 | Float | read-only | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.30.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| STR labelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.57 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR uomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| FLO majorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.63 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.64 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.65 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.66 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR labelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Laser Temperature Analog parameter. |
| STR uomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| FLO majorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.74 | Float | read-only | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.76 | Float | read-only | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.77 | Float | read-only | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| STR labelModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR uomModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO majorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.85 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.87 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.88 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateModuleTemp | 1.3.6.1.4.1.1166.6.1.2.30.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.96 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.98 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.99 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.30.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR label12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.101 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR uom12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.107 | Float | read-only | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.108 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.109 | Float | read-only | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.110 | Float | read-only | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.30.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2emDigitalTable | 1.3.6.1.4.1.1166.6.1.2.30.3 | not-accessible | This table contains gx2Em specific parameters with nominal and current values. | |
| gx2emDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.30.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2emDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.30.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelRfInput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR enumRfInput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT valueRfInput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT stateflagRfInput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelOptOutput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Optical Output Control Digital parameter. |
| STR enumOptOutput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT valueOptOutput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT stateflagOptOutput | 1.3.6.1.4.1.1166.6.1.2.30.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelLaserMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Laser Mode Digital parameter. |
| STR enumLaserMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT valueLaserMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT stateflagLaserMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| STR enumLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT valueLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT stateflagLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.30.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelVideoOffset | 1.3.6.1.4.1.1166.6.1.2.30.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Video Offset Digital parameter. |
| STR enumVideoOffset | 1.3.6.1.4.1.1166.6.1.2.30.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.. |
| INT valueVideoOffset | 1.3.6.1.4.1.1166.6.1.2.30.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT stateflagVideoOffset | 1.3.6.1.4.1.1166.6.1.2.30.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.30.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.30.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.30.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT stateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.30.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2emStatusTable | 1.3.6.1.4.1.1166.6.1.2.30.4 | not-accessible | This table contains gx2Em specific parameters with nominal and current values. | |
| gx2emStatusEntry | 1.3.6.1.4.1.1166.6.1.2.30.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2emStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.30.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelBoot | 1.3.6.1.4.1.1166.6.1.2.30.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT valueBoot | 1.3.6.1.4.1.1166.6.1.2.30.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.30.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelFlash | 1.3.6.1.4.1.1166.6.1.2.30.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT valueFlash | 1.3.6.1.4.1.1166.6.1.2.30.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.30.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.30.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.30.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.30.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.30.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT valueLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.30.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateflagLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.30.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.30.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT valueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.30.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.30.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelHWStatus | 1.3.6.1.4.1.1166.6.1.2.30.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Laser Drive Level Status parameter. |
| INT valueHWStatus | 1.3.6.1.4.1.1166.6.1.2.30.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateflagHWStatus | 1.3.6.1.4.1.1166.6.1.2.30.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.30.4.3.20 | DisplayString | read-only | The value of this object provides the label of the RF Input Status parameter. |
| INT valueRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.30.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateflagRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.30.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2emFactoryTable | 1.3.6.1.4.1.1166.6.1.2.30.5 | not-accessible | This table contains gx2Em specific parameters with nominal and current values. | |
| gx2emFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.30.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2emFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.30.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT bootControlByteValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT bootStatusByteValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT bank1CRCValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT bank2CRCValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT prgEEPROMByteValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT factoryCRCValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT calculateCRCValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT hourMeterValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT flashPrgCntAValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT flashPrgCntBValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR flashBankARevValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR flashBankBRevValue | 1.3.6.1.4.1.1166.6.1.2.30.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| gx2Em1000HoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.30.6 | not-accessible | This table contains gx2Em1000 specific parameters with nominal and current values. | |
| gx2Em1000HoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.30.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Em1000HoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.30.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT gx2Em1000HoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.30.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT gx2Em1000HoldTimeData | 1.3.6.1.4.1.1166.6.1.2.30.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
HFC (Hybrid Fiber-Coaxial) network management for OMNI gx2EM laser modules with device descriptors and parameters.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.