Type: INTEGER

Access: read-write

Description: The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.

What is gx2Em1000HoldTimeData?

This sets the alarm hold-time, in seconds, for the specific alarm object identified by gx2Em1000HoldTimeSpecIndex, used to suppress transient noise so a brief threshold crossing doesn't immediately fire an alarm. The source MIB documents a valid range of 0 to 1300 seconds and describes a byte-level encoding for validation and hold-time data within this 32-bit value, though the specific per-index alarm mapping it references was never actually filled in with real values in the source text. An administrator increases this value to make an alarm more tolerant of brief fluctuations, at the cost of slower alarm reporting when a real fault occurs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.6.5.3
snmpwalk -v2c -c public <target> OMNI-gx2EM-MIB::gx2Em1000HoldTimeData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.6.5.3.1
snmpget -v2c -c public <target> OMNI-gx2EM-MIB::gx2Em1000HoldTimeData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.30.6.5.3.1 i <value>

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EM-MIB::gx2Em1000HoldTimeData OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.30gx2Em1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.30.6gx2Em1000HoldTimeTableOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.6.5gx2Em1000HoldTimeEntryOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.6.5.3gx2Em1000HoldTimeDataOMNI-gx2EM-MIB