majorHigh12Volt

Module: OMNI-gx2EM-MIB

OID (symbolic): OMNI-gx2EM-MIB::majorHigh12Volt

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.30.2.1.103

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is majorHigh12Volt?

This reports the major-high alarm threshold configured for the module's 12V Supply Current reading, as an IEEE 32-bit floating point number. Monitoring software raises a major alarm when the live 12V Supply Current reading climbs above this threshold. An administrator tunes it to reflect how far above normal 12V Supply Current can safely drift before it represents a real fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.103
snmpwalk -v2c -c public <target> OMNI-gx2EM-MIB::majorHigh12Volt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.103.1
snmpget -v2c -c public <target> OMNI-gx2EM-MIB::majorHigh12Volt.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> majorHigh12Volt.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EM-MIB::majorHigh12Volt OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.30gx2Em1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.30.2gx2emAnalogTableOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1gx2emAnalogEntryOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1.103majorHigh12VoltOMNI-gx2EM-MIB