All MIBs › OMNI-gx2OSW10B-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 OSW10B optical switch module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2OSW10B-MIB?
This MIB manages the Cisco/Scientific-Atlanta GX2 OSW10B optical switch module, a component in HFC optical node deployments used for optical path switching/protection (e.g., redundant fiber path failover) at the cable network node. The provided source contained only a placeholder object entry, so no concrete object list is available, but as a GX2 OMNI-family switch module MIB it would be expected to expose module identity, active optical path/port selection, and switch alarm/fault status. Its monitoring value centers on hardware status of the optical switch -- confirming which optical path is currently active, whether a protection switchover has occurred, and whether any fault is asserted -- which is directly relevant to fiber-path redundancy health in HFC networks. It is a vendor-specific module tied to the Cisco/Scientific-Atlanta OMNI optical node management architecture rather than IETF standards. It is deployed on Cisco/Scientific-Atlanta GX2 optical nodes in HFC cable network outside-plant deployments, where OMNI-gx2OSW10B-MIB SNMP monitoring supports early detection of optical path failover events.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2OSW10B-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 OSW10B optical switch module)
Monitoring Examples
No usable sample objects were available for this MIB in the provided source (only a placeholder entry), so specific object names cannot be cited; based on its stated purpose, an operator would typically poll active optical path/port selection and switch alarm/fault objects for the OSW10B module within the GX2 node's OMNI object tree. An unexpected active-path change would indicate the optical switch has performed a protection failover, potentially due to a fiber cut or degraded primary path. A persistent alarm/fault status on the module would indicate the switch itself needs field replacement to restore protection redundancy.
What Can Be Monitored
- active optical path/port selection
- protection switchover events
- module alarm/fault status
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Osw10b | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC1155-SMI
| Counter |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapOSW10BConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.15.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapOSW10BConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.15.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapOSW10BOpticalInputAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.3 | This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of this parameter. | ||
| NTF trapOSW10BFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.4 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapOSW10BModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.5 | This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapOSW10BFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.6 | This trap is issued when the detects an error during Flash memory operations. | ||
| NTF trapOSW10BBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.7 | This trap is issued when the detects an error while booting from bank 0 or bank 1. | ||
| NTF trapOSW10BCaliDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.8 | This trap is issued when the optical calibration table corrupted. | ||
| NTF trapOSW10BFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.9 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapOSW10BAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.10 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapOSW10BInputSwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.11 | This trap is issued when the Optical input switched. This is info only alarm, unit nothing wrong | ||
| NTF trapOSW10BResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.12 | This trap is issued when the Factory Default Reset occurs. This is info only | ||
| NTF trapOSW10BSecondaryInputActiveAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.13 | This trap is issued when the secondary input becomes active. | ||
| NTF trapOSW10BPriOpticInputAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.14 | This trap is issued when primary optical input out of range. | ||
| NTF trapOSW10BSecOpticInputAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.15 | This trap is issued when Sec optical input out of range. | ||
| NTF trapOSW10BHardwareErrorAlarm | 1.3.6.1.4.1.1166.6.1.2.15.0.16 | This trap is issued when hardware error happens. | ||
| gx2Osw10bDescriptor | 1.3.6.1.4.1.1166.6.1.2.15.1 | |||
| gx2Osw10bAnalogTable | 1.3.6.1.4.1.1166.6.1.2.15.2 | not-accessible | This table contains gx2Osw10b specific parameters with nominal and current values. | |
| gx2Osw10bAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.15.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2Osw10bAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.15.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR osw10blabelPriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Primary Optical Input Level Analog parameter. |
| STR osw10buomPriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Primary Optical Input Level Analog parameter. |
| FLO osw10bmajorHighPriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Primary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmajorLowPriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Primary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorHighPriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Primary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorLowPriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Primary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bcurrentValuePriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.8 | Float | read-only | The value of this object provides the Current value of the Primary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10bstateFlagPriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Primary Optical Input Level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO osw10bminValuePriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.10 | Float | read-only | The value of this object provides the minimum value the Primary Optical Input Level Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmaxValuePriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.11 | Float | read-only | The value of this object provides the maximum value the Primary Optical Input Level Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10balarmStatePriOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.12 | INTEGER | read-only | The value of this object provides the current alarm state of the Primary Optical Input Level Analog parameter. |
| STR osw10blabelSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Secondary Optical Input Level Analog parameter. |
| STR osw10buomSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Secondary Optical Input Level Analog parameter. |
| FLO osw10bmajorHighSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Secondary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmajorLowSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Secondary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorHighSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Secondary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorLowSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Secondary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bcurrentValueSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.19 | Float | read-only | The value of this object provides the Current value of the Secondary Optical Input Level Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10bstateFlagSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Secondary Optical Input Level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO osw10bminValueSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.21 | Float | read-only | The value of this object provides the minimum value the Secondary Optical Input Level Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmaxValueSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.22 | Float | read-only | The value of this object provides the maximum value the Secondary Optical Input Level Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10balarmStateSecOpticalInputLevel | 1.3.6.1.4.1.1166.6.1.2.15.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Secondary Optical Input Level Analog parameter. |
| STR osw10blabelPriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Primary Optical Input Threshold Analog parameter. |
| STR osw10buomPriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Primary Optical Input Threshold Analog parameter. |
| FLO osw10bmajorHighPriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Primary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmajorLowPriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Primary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorHighPriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Primary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorLowPriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Primary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bcurrentValuePriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.30 | Float | read-write | The value of this object provides the Current value of the Primary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10bstateFlagPriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Primary Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO osw10bminValuePriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.32 | Float | read-write | The value of this object provides the minimum value the Primary Optical Input Threshold Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmaxValuePriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.33 | Float | read-only | The value of this object provides the maximum value the Primary Optical Input Threshold Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10balarmStatePriOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Primary Optical Threshold Analog parameter. |
| STR osw10blabelSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Secondary Optical Input Threshold Analog parameter. |
| STR osw10buomSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Secondary Optical Input Threshold Analog parameter. |
| FLO osw10bmajorHighSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Secondary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmajorLowSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Secondary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorHighSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Secondary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorLowSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Secondary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bcurrentValueSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.41 | Float | read-write | The value of this object provides the Current value of the Secondary Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10bstateFlagSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Secondary Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO osw10bminValueSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.43 | Float | read-only | The value of this object provides the minimum value the Secondary Optical Input Threshold Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmaxValueSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.44 | Float | read-only | The value of this object provides the maximum value the Secondary Optical Input Threshold Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10balarmStateSecOpticalThreshold | 1.3.6.1.4.1.1166.6.1.2.15.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Secondary Optical Threshold Analog parameter. |
| STR osw10blabelModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR osw10buomModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO osw10bmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.52 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10bstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO osw10bminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.54 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.55 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10balarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.15.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR osw10blabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR osw10buomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO osw10bmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.63 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10bstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO osw10bminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.65 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO osw10bmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.66 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT osw10balarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.15.2.1.67 | INTEGER | read-only | The value of this object provides the current alarm state of the Fan Current Analog parameter. |
| gx2Osw10bDigitalTable | 1.3.6.1.4.1.1166.6.1.2.15.3 | not-accessible | This table contains gx2Osw10b specific parameters with nominal and current values. | |
| gx2Osw10bDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.15.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2Osw10bDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.15.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR osw10blabelSwitchControl | 1.3.6.1.4.1.1166.6.1.2.15.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Switch Control Digital parameter. |
| STR osw10benumSwitchControl | 1.3.6.1.4.1.1166.6.1.2.15.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueSwitchControl | 1.3.6.1.4.1.1166.6.1.2.15.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT osw10bstateflagSwitchControl | 1.3.6.1.4.1.1166.6.1.2.15.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelSwitchMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Switch Control Digital parameter. |
| STR osw10benumSwitchMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueSwitchMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT osw10bstateflagSwitchMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.9 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelRevertMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Revert Mode Digital parameter. |
| STR osw10benumRevertMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueRevertMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT osw10bstateflagRevertMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelRevertTime | 1.3.6.1.4.1.1166.6.1.2.15.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Revert Time Digital parameter. |
| STR osw10benumRevertTime | 1.3.6.1.4.1.1166.6.1.2.15.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueRevertTime | 1.3.6.1.4.1.1166.6.1.2.15.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT osw10bstateflagRevertTime | 1.3.6.1.4.1.1166.6.1.2.15.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelWavelength | 1.3.6.1.4.1.1166.6.1.2.15.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Wavelength Digital parameter. |
| STR osw10benumWavelength | 1.3.6.1.4.1.1166.6.1.2.15.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueWavelength | 1.3.6.1.4.1.1166.6.1.2.15.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT osw10bstateflagWavelength | 1.3.6.1.4.1.1166.6.1.2.15.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hiden 1-Read-Only, 2-Updateable). |
| STR osw10blabelSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.15.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Switch State Digital parameter. |
| STR osw10benumSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.15.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.15.3.2.24 | INTEGER | read-only | The value of this object is the current value of the parameter. |
| INT osw10bstateflagSwitchMonitor | 1.3.6.1.4.1.1166.6.1.2.15.3.2.25 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelOperationMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.26 | DisplayString | read-only | The value of this object provides the label of the Switch State Digital parameter. |
| STR osw10benumOperationMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueOperationMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.28 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT osw10bstateflagOperationMode | 1.3.6.1.4.1.1166.6.1.2.15.3.2.29 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.15.3.2.30 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR osw10benumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.15.3.2.31 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT osw10bvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.15.3.2.32 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT osw10bstateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.15.3.2.33 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Osw10bStatusTable | 1.3.6.1.4.1.1166.6.1.2.15.4 | not-accessible | This table contains gx2Osw10b specific parameters with nominal and current values. | |
| gx2Osw10bStatusEntry | 1.3.6.1.4.1.1166.6.1.2.15.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2Osw10bStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.15.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR osw10blabelBoot | 1.3.6.1.4.1.1166.6.1.2.15.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status parameter. |
| INT osw10bvalueBoot | 1.3.6.1.4.1.1166.6.1.2.15.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.15.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelFlash | 1.3.6.1.4.1.1166.6.1.2.15.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status parameter. |
| INT osw10bvalueFlash | 1.3.6.1.4.1.1166.6.1.2.15.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.15.4.3.7 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.15.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT osw10bvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.15.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.15.4.3.10 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelCalibrateTableStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.11 | DisplayString | read-only | The value of this object provides the label of optical input calibration table status description |
| INT osw10bvalueCalibrateTableStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagCalibrateTableStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.13 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.15.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT osw10bvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.15.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.15.4.3.16 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelInputStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Input Status parameter. |
| INT osw10bvalueInputStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagInputStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.19 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelPriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Primary Active Status parameter. |
| INT osw10bvaluePriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagPriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.22 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelHardwareErr | 1.3.6.1.4.1.1166.6.1.2.15.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Primary Active Status parameter. |
| INT osw10bvalueHardwareErr | 1.3.6.1.4.1.1166.6.1.2.15.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagHardwareErr | 1.3.6.1.4.1.1166.6.1.2.15.4.3.25 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelPriThresholdStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.26 | DisplayString | read-only | The value of this object provides the label of the Primary Input Below The Threshold Status parameter. |
| INT osw10bvaluePriThresholdStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.27 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagPriThresholdStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.28 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR osw10blabelSecThresholdStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.29 | DisplayString | read-only | The value of this object provides the label of the Primary Input Below The Threshold Status parameter. |
| INT osw10bvalueSecThresholdStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.30 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT osw10bstateflagSecThresholdStatus | 1.3.6.1.4.1.1166.6.1.2.15.4.3.31 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Osw10bFactoryTable | 1.3.6.1.4.1.1166.6.1.2.15.5 | not-accessible | This table contains gx2Osw10b specific parameters with nominal and current values. | |
| gx2Osw10bFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.15.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2Osw10bFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.15.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT osw10bbootControlByte | 1.3.6.1.4.1.1166.6.1.2.15.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT osw10bbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.15.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT osw10bbank1CRC | 1.3.6.1.4.1.1166.6.1.2.15.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT osw10bbank2CRC | 1.3.6.1.4.1.1166.6.1.2.15.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT osw10bprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.15.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT osw10bfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.15.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT osw10bcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.15.5.4.8 | INTEGER | read-only | This object indicates which of the Enums will have the CRC calculated. |
| INT osw10bhourMeter | 1.3.6.1.4.1.1166.6.1.2.15.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT osw10bflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.15.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT osw10bflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.15.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR osw10bflashBankARev | 1.3.6.1.4.1.1166.6.1.2.15.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR osw10bflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.15.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| gx2Osw10bHoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.15.6 | not-accessible | This table contains gx2Osw10b specific parameters with nominal and current values. | |
| gx2Osw10bHoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.15.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2Osw10bHoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.15.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT rxgx2Osw10bHoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.15.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT rxgx2Osw10bHoldTimeData | 1.3.6.1.4.1.1166.6.1.2.15.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Manages OMNISTAR GX2 optical switch network elements in HFC networks.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 OSW10B optical switch module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.