OMNI-gx2EM-MIB :: majorLowTecCurrent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2EM-MIB › majorLowTecCurrent

majorLowTecCurrent

Module: OMNI-gx2EM-MIB

OID (symbolic): OMNI-gx2EM-MIB::majorLowTecCurrent

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.30.2.1.60

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is majorLowTecCurrent?

This reports the major-low alarm threshold configured for the module's TEC (thermoelectric cooler) Current reading, as an IEEE 32-bit floating point number. Monitoring software raises a major alarm when the live TEC (thermoelectric cooler) Current reading drops below this threshold. An administrator sets it to the point below which TEC (thermoelectric cooler) Current is considered seriously out of range rather than just drifting.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.60
snmpwalk -v2c -c public <target> OMNI-gx2EM-MIB::majorLowTecCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.60.1
snmpget -v2c -c public <target> OMNI-gx2EM-MIB::majorLowTecCurrent.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EM-MIB::majorLowTecCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.30gx2Em1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.30.2gx2emAnalogTableOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1gx2emAnalogEntryOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1.60majorLowTecCurrentOMNI-gx2EM-MIB