All MIBs › OMNI-gx2Em870-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 EM870 870 MHz expansion module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2Em870-MIB?
This MIB manages the Cisco (originally Scientific-Atlanta) GX2 EM870 870 MHz expansion module, a plug-in card used in GX2-series hybrid fiber-coax (HFC) optical nodes to extend RF bandwidth handling in cable television/broadband access networks. No sample objects were provided in this batch, but expansion-module MIBs in this OMNI family typically expose module presence/identity, RF signal level, and operational status objects for the card slot. Its role is hardware status monitoring for the optical node: confirming the EM870 module is present, correctly identified, and operating within expected RF signal parameters, which affects downstream/upstream signal quality delivered to subscribers. It is part of Cisco/Scientific-Atlanta's proprietary GX2 optical node MIB family (OMNI-*) rather than an IETF standard, and is likely referenced alongside sibling node/shelf MIBs for full node management. It is deployed in cable operator HFC networks wherever a GX2 optical node is fitted with an 870 MHz expansion module to support extended-spectrum service. Engineers can download the OMNI-gx2Em870-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2Em870-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM870 870 MHz expansion module)
Monitoring Examples
An operator would poll the module's identity and status objects (following the OMNI-gx2 module pattern) to confirm the EM870 card is inserted, recognized, and reporting a healthy operational state in its optical node slot. A module reporting missing or a fault status would indicate a card failure or seating issue requiring a field truck roll. Because no object names were available in this batch, exact object names cannot be confirmed and this description reflects the module's known general purpose within the GX2 product line.
What Can Be Monitored
- module presence/identity
- module operational status
- RF signal level
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Em870 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapEM870ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.12.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEM870ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.12.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEM870FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.3 | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEM87012vAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.4 | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEM870ModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.5 | This trap is issued when the Module Temperature goes out of range. | ||
| NTF trapEM870OmiOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.6 | This trap is issued when the Laser Modules OMI level parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEM870OpticalOutputPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.7 | This trap is issued when the Laser Modules Optical Output power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapEM870FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.8 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapEM870BankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.9 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapEM870AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.10 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapEM870FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.12.0.11 | This trap is issued when the Factory Data CRC is incorrect. | ||
| gx2Em870Descriptor | 1.3.6.1.4.1.1166.6.1.2.12.1 | |||
| gx2Em870AnalogTable | 1.3.6.1.4.1.1166.6.1.2.12.2 | not-accessible | This table contains gx2Em870 specific parameters with nominal and current values. | |
| gx2Em870AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.12.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2Em870AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.12.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR em870labelOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Optical Output Power Analog parameter. |
| STR em870uomOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter. |
| FLO em870majorHighOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.8 | Float | read-only | The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlagOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.10 | Float | read-only | The value of this object provides the minimum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.11 | Float | read-only | The value of this object provides the maximum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateOpticalPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Output Power Analog parameter. |
| STR em870labelOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.13 | DisplayString | read-only | The value of this object provides the label of the RF Input Power Analog parameter. |
| STR em870uomOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Input Power Analog parameter.. |
| FLO em870majorHighOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.19 | Float | read-only | The value of this object provides the Current value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. +99 dB or -99 dB will be reported for this value when outside the min/max operating range. |
| INT em870stateFlagOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.20 | INTEGER | read-only | The value of this object provides the state of the RF Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.21 | Float | read-only | The value of this object provides the minimum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.22 | Float | read-only | The value of this object provides the maximum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateOmiOffset | 1.3.6.1.4.1.1166.6.1.2.12.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Input Power Analog parameter. |
| STR em870labelDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.24 | DisplayString | read-only | The value of this object provides the label of the DFB Output Power Current Analog parameter. |
| STR em870uomDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the DFB Output Power Analog parameter. |
| FLO em870majorHighDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.30 | Float | read-only | The value of this object provides the Current value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlagDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.31 | INTEGER | read-only | The value of this object provides the state of the DFB Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.32 | Float | read-only | The value of this object provides the minimum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.33 | Float | read-only | The value of this object provides the maximum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateDFBPower | 1.3.6.1.4.1.1166.6.1.2.12.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the DFB Output Power Analog parameter. |
| STR em870labelLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR em870uomLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| FLO em870majorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.41 | Float | read-only | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.43 | Float | read-only | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.44 | Float | read-only | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.12.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| STR em870labelCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Cooler Current Analog parameter. |
| STR em870uomCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Cooler Current Analog parameter.. |
| FLO em870majorHighCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.52 | Float | read-only | The value of this object provides the Current value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlagCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Cooler Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.54 | Float | read-only | The value of this object provides the minimum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.55 | Float | read-only | The value of this object provides the maximum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateCoolerCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Cooler Current Analog parameter. |
| STR em870labelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Laser Temp Analog parameter. |
| STR em870uomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temp Analog parameter. |
| FLO em870majorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.63 | Float | read-only | The value of this object provides the Current value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Laser Temp Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.65 | Float | read-only | The value of this object provides the minimum value the Laser TempAnalog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.66 | Float | read-only | The value of this object provides the maximum value the Laser Temp Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temp Analog parameter. |
| STR em870labelModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR em870uomModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO em870majorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.74 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.76 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.77 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.12.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR em870labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR em870uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO em870majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.85 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.87 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.88 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.12.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR em870label12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.90 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR em870uom12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO em870majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.96 | Float | read-only | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.97 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO em870minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.98 | Float | read-only | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO em870maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.99 | Float | read-only | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT em870alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.12.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2Em870DigitalTable | 1.3.6.1.4.1.1166.6.1.2.12.3 | not-accessible | This table contains gx2Em870 specific parameters with nominal and current values. | |
| gx2Em870DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.12.3.4 | not-accessible | This list contains the digital parameters and descriptions. | |
| INT gx2Em870DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.12.3.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR em870labelOpticalAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.12.3.4.2 | DisplayString | read-only | The value of this object provides the label of the EM870's Optical Alarm setpoint Digital parameter. |
| STR em870enumOpticalAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.12.3.4.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT em870valueOpticalAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.12.3.4.4 | INTEGER | read-write | The value of this object is the current value of the parameter. Note that reset setting returns the parameter to the off setting |
| INT em870stateFlagOpticalAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.12.3.4.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Em870StatusTable | 1.3.6.1.4.1.1166.6.1.2.12.4 | not-accessible | This table contains gx2Em870 specific parameters with nominal and current values. | |
| gx2Em870StatusEntry | 1.3.6.1.4.1.1166.6.1.2.12.4.2 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2Em870StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.12.4.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR em870labelBoot | 1.3.6.1.4.1.1166.6.1.2.12.4.2.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT em870valueBoot | 1.3.6.1.4.1.1166.6.1.2.12.4.2.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT em870stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.12.4.2.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR em870labelFlash | 1.3.6.1.4.1.1166.6.1.2.12.4.2.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT em870valueFlash | 1.3.6.1.4.1.1166.6.1.2.12.4.2.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT em870stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.12.4.2.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR em870labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.12.4.2.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT em870valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.12.4.2.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT em870stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.12.4.2.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR em870labelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.12.4.2.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT em870valueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.12.4.2.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT em870stateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.12.4.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR em870labelCsoStatus | 1.3.6.1.4.1.1166.6.1.2.12.4.2.14 | DisplayString | read-only | The value of this object provides the label of the CSO Status parameter. This parameter is always hidden |
| INT em870valueCsoStatus | 1.3.6.1.4.1.1166.6.1.2.12.4.2.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT em870stateflagCsoStatus | 1.3.6.1.4.1.1166.6.1.2.12.4.2.16 | INTEGER | read-only | The value of this object provides the state of the the CSO Status parameter. This parameter is always hidden (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Em870FactoryTable | 1.3.6.1.4.1.1166.6.1.2.12.5 | not-accessible | This table contains gx2Em870 specific parameters with nominal and current values. | |
| gx2Em870FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.12.5.3 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2Em870FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.12.5.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT em870bootControlByte | 1.3.6.1.4.1.1166.6.1.2.12.5.3.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT em870bootStatusByte | 1.3.6.1.4.1.1166.6.1.2.12.5.3.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT em870bank1CRC | 1.3.6.1.4.1.1166.6.1.2.12.5.3.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT em870bank2CRC | 1.3.6.1.4.1.1166.6.1.2.12.5.3.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT em870prgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.12.5.3.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT em870factoryCRC | 1.3.6.1.4.1.1166.6.1.2.12.5.3.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT em870calculateCRC | 1.3.6.1.4.1.1166.6.1.2.12.5.3.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT em870hourMeter | 1.3.6.1.4.1.1166.6.1.2.12.5.3.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT em870flashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.12.5.3.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT em870flashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.12.5.3.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR em870flashBankARev | 1.3.6.1.4.1.1166.6.1.2.12.5.3.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR em870flashBankBRev | 1.3.6.1.4.1.1166.6.1.2.12.5.3.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| gx2Em870HoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.12.6 | not-accessible | This table contains gx2EM870 specific parameters with nominal and current values. | |
| gx2Em870HoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.12.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Em870HoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.12.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT gx2Em870HoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.12.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT gx2Em870HoldTimeData | 1.3.6.1.4.1.1166.6.1.2.12.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Monitors OMNISTAR Laser Module (Forward Path Transmitter) optical parameters and alarm limits in HFC networks.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM870 870 MHz expansion module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.