All MIBs › OMNI-gx2GS1000-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 GS1000 gigabit Ethernet switch module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2GS1000-MIB?
This MIB manages the Cisco/Scientific-Atlanta GX2 GS1000 gigabit Ethernet switch module, a component installed in HFC optical nodes to provide gigabit Ethernet switching capability at the cable network node. No object list was captured for this module in the provided source, but as a GX2 OMNI-family switch module MIB it would be expected to expose module identity, per-port link/speed status, and alarm conditions for the switch card. Its monitoring value centers on hardware/link status of the switch module -- confirming the module is installed and healthy, and each Ethernet port is linked at the expected speed -- rather than exposing detailed traffic counters. It is a vendor-specific module tied to the Cisco/Scientific-Atlanta OMNI optical node management architecture rather than IETF standards. It is deployed on Cisco/Scientific-Atlanta GX2 optical nodes in HFC cable network outside-plant deployments. Engineers can download the OMNI-gx2GS1000-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2GS1000-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 GS1000 gigabit Ethernet switch module)
Monitoring Examples
No sample objects were available for this MIB in the provided source, so specific object names cannot be cited; based on its stated purpose, an operator would typically poll module presence/identity and per-port link-status/speed objects for the GS1000 switch card within the GX2 node's OMNI object tree. A port reporting link-down or a lower-than-expected negotiated speed would indicate a cabling or hardware fault on that switch port. This module is primarily a hardware-presence and port link-status monitor for the gigabit switch card rather than a traffic-statistics MIB.
What Can Be Monitored
- module presence/identity
- per-port link status/speed
- module alarm/fault status
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Gs1000 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapGS1000ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.36.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapGS1000ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.36.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapGS1000RFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.3 | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000RFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.4 | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000RFOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.5 | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000OpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.6 | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000LaserBiasAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.7 | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000LaserTempAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.8 | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000TECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.9 | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000Fan1SpeedAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.10 | This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000Fan2SpeedAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.11 | This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS100012vAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.12 | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapGS1000ModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.13 | This trap is issued when the Laser Module Temperature goes out of range. | ||
| NTF trapGS1000FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.14 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapGS1000LaserBiasCntLoopAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.15 | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| NTF trapGS1000BankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.16 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapGS1000LaserBiasCntLoopInitAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.17 | This trap is issued when the Laser Bias Control loop init fails. | ||
| NTF trapGS1000RFParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.18 | This trap is issued when the RF parameter Init fails. | ||
| NTF trapGS1000TECParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.19 | This trap is issued when the TEC Parameter Init fails. | ||
| NTF trapGS1000AttnTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.20 | This trap is issued when the Attenuator Table Init fails. | ||
| NTF trapGS1000PowerMeterTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.21 | This trap is issued when the Power Meter Table Init fails. | ||
| NTF trapGS1000LaserDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.22 | This trap is issued when the Laser Data CRC is incorrect. | ||
| NTF trapGS1000AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.23 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapGS1000FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.24 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapGS1000UserRFOffAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.25 | This trap is issued when the the User RF is turned off. | ||
| NTF trapGS1000UserOpticalOffAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.26 | This trap is issued when the User Optical Power is turned off. | ||
| NTF trapGS1000ResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.36.0.27 | This trap is issued when the Factory Default Reset occurs. | ||
| gx2gs1000Descriptor | 1.3.6.1.4.1.1166.6.1.2.36.1 | |||
| gx2gs1000AnalogTable | 1.3.6.1.4.1.1166.6.1.2.36.2 | not-accessible | This table contains gx2Gs1000 specific parameters with nominal and current values. | |
| gx2gs1000AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.36.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2gs1000AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.36.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR gs1000labelOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Offset Monitor Analog parameter. |
| STR gs1000uomOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| FLO gs1000majorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000majorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO gs1000minorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO gs1000currentValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.8 | Float | read-only | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO gs1000minValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.10 | Float | read-only | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.11 | Float | read-only | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.36.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| STR gs1000labelOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| STR gs1000uomOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.14 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| FLO gs1000majorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000majorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000minorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000minorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000currentValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.19 | Float | read-write | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO gs1000minValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.21 | Float | read-only | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.22 | Float | read-only | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| STR gs1000labelOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR gs1000uomOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO gs1000majorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000majorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000minorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000currentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.30 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValueOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.32 | Float | read-only | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.33 | Float | read-only | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.36.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR gs1000labelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Laser Temperature Analog parameter. |
| STR gs1000uomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| FLO gs1000majorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000majorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000currentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.41 | Float | read-only | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.43 | Float | read-only | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.44 | Float | read-only | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| STR gs1000labelLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR gs1000uomLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| FLO gs1000majorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000majorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000minorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000currentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.52 | Float | read-only | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.54 | Float | read-only | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.55 | Float | read-only | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.36.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| STR gs1000labelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.57 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR gs1000uomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| FLO gs1000majorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000majorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000minorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000currentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.63 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.64 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.65 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.66 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.36.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR gs1000labelModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR gs1000uomModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO gs1000majorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000majorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000currentValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.74 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.76 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.77 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateModuleTemp | 1.3.6.1.4.1.1166.6.1.2.36.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR gs1000labelFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Fan 1 Speed Analog parameter. |
| STR gs1000uomFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter. |
| FLO gs1000majorHighFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000majorLowFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000minorLowFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000currentValueFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.85 | Float | read-only | The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValueFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.87 | Float | read-only | The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.88 | Float | read-only | The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateFan1Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter. |
| STR gs1000labelFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Fan 2 Speed Analog parameter. |
| STR gs1000uomFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter. |
| FLO gs1000majorHighFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000majorLowFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHighFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000) |
| FLO gs1000minorLowFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000currentValueFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.96 | Float | read-only | The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlagFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValueFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.98 | Float | read-only | The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValueFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.99 | Float | read-only | The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmStateFan2Speed | 1.3.6.1.4.1.1166.6.1.2.36.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter. |
| STR gs1000label12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.101 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR gs1000uom12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO gs1000majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.107 | Float | read-only | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.108 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO gs1000minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.109 | Float | read-only | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO gs1000maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.110 | Float | read-only | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT gs1000alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.36.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2gs1000DigitalTable | 1.3.6.1.4.1.1166.6.1.2.36.3 | not-accessible | This table contains gx2Gs1000 specific parameters with nominal and current values. | |
| gx2gs1000DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.36.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2gs1000DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.36.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR gs1000labelRfInput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR gs1000enumRfInput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT gs1000valueRfInput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT gs1000stateflagRfInput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelOptOutput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Optical Output Control Digital parameter. |
| STR gs1000enumOptOutput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT gs1000valueOptOutput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT gs1000stateflagOptOutput | 1.3.6.1.4.1.1166.6.1.2.36.3.2.9 | INTEGER | read-only | The value of this object provides the gs1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelLaserMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Laser Mode Digital parameter. |
| STR gs1000enumLaserMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT gs1000valueLaserMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT gs1000stateflagLaserMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.36.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Attenuation Setting Ditital Parameter. |
| STR gs1000enumAttenSetting | 1.3.6.1.4.1.1166.6.1.2.36.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT gs1000valueAttenSetting | 1.3.6.1.4.1.1166.6.1.2.36.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT gs1000stateflagAttenSetting | 1.3.6.1.4.1.1166.6.1.2.36.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| STR gs1000enumLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT gs1000valueLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT gs1000stateflagLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.36.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelVideoOffset | 1.3.6.1.4.1.1166.6.1.2.36.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Video Offset Digital parameter. |
| STR gs1000enumVideoOffset | 1.3.6.1.4.1.1166.6.1.2.36.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.. |
| INT gs1000valueVideoOffset | 1.3.6.1.4.1.1166.6.1.2.36.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT gs1000stateflagVideoOffset | 1.3.6.1.4.1.1166.6.1.2.36.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.36.3.2.26 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR gs1000enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.36.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT gs1000valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.36.3.2.28 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT gs1000stateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.36.3.2.29 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2gs1000StatusTable | 1.3.6.1.4.1.1166.6.1.2.36.4 | not-accessible | This table contains gx2Gs1000 specific parameters with nominal and current values. | |
| gx2gs1000StatusEntry | 1.3.6.1.4.1.1166.6.1.2.36.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2gs1000StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.36.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR gs1000labelBoot | 1.3.6.1.4.1.1166.6.1.2.36.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT gs1000valueBoot | 1.3.6.1.4.1.1166.6.1.2.36.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT gs1000stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.36.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelFlash | 1.3.6.1.4.1.1166.6.1.2.36.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT gs1000valueFlash | 1.3.6.1.4.1.1166.6.1.2.36.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT gs1000stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.36.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.36.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT gs1000valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.36.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT gs1000stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.36.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.36.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT gs1000valueLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.36.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT gs1000stateflagLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.36.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.36.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT gs1000valueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.36.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT gs1000stateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.36.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR gs1000labelRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.36.4.3.17 | DisplayString | read-only | The value of this object provides the label of the RF Input Status parameter. |
| INT gs1000valueRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.36.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT gs1000stateflagRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.36.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2gs1000FactoryTable | 1.3.6.1.4.1.1166.6.1.2.36.5 | not-accessible | This table contains gx2Gs1000 specific parameters with nominal and current values. | |
| gx2gs1000FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.36.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2gs1000FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.36.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT gs1000bootControlByteValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT gs1000bootStatusByteValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT gs1000bank1CRCValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT gs1000bank2CRCValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT gs1000prgEEPROMByteValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT gs1000factoryCRCValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT gs1000calculateCRCValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT gs1000hourMeterValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT gs1000flashPrgCntAValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT gs1000flashPrgCntBValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR gs1000flashBankARevValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR gs1000flashBankBRevValue | 1.3.6.1.4.1.1166.6.1.2.36.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
RFC description
Manages OMNISTAR GS1000 laser modules (1550nm forward path transmitters) in HFC networks.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 GS1000 gigabit Ethernet switch module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.