All MIBs › OMNI-gx2PSDC-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 PSDC DC power supply module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2PSDC-MIB?
This MIB manages the Cisco (originally Scientific-Atlanta) GX2 PSDC DC power supply module, a field-replaceable power unit used in GX2-series HFC optical nodes in cable broadband access networks. No sample objects were provided in this batch, but power-supply MIBs in this OMNI family typically expose module presence, input/output voltage or current readings, and a power supply health/fault status. Its purpose is direct hardware status monitoring: detecting a failing or degraded DC power supply in an optical node before it causes a node outage, particularly important since many nodes rely on redundant power supplies to stay up during a single-unit failure. It belongs to Cisco/Scientific-Atlanta's proprietary GX2 optical node MIB family rather than any IETF standard, and complements sibling module MIBs (e.g., receiver/expansion cards) covering the rest of the node. It is deployed in cable operator HFC networks on GX2 optical nodes powered by DC supplies, typically in outside-plant cabinets. Engineers can download the OMNI-gx2PSDC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2PSDC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco/Scientific-Atlanta GX2 HFC optical node (PSDC power supply module)
- General Instrument/Motorola OmniStar GX2 HFC headend equipment
Monitoring Examples
An operator would poll the PSDC module's presence and fault-status objects (per the OMNI-gx2 module pattern) to confirm the DC power supply is installed and healthy, and would check any output voltage/current objects for values outside the expected range. A reported fault or missing-module status on a PSDC unit in a node with only one operating supply would be treated as an urgent dispatch since it removes power redundancy. Because no object names were available in this batch, exact object names cannot be confirmed and this description reflects the module's known general purpose.
What Can Be Monitored
- power supply presence
- power supply fault status
- output voltage/current
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Psdc | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapPSDCConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.7.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapPSDCConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.7.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapPSDCFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.0.3 | This trap is issued when a Fan Current event has occurred. | ||
| NTF trapPSDC12Volt | 1.3.6.1.4.1.1166.6.1.2.7.0.4 | This trap is issued when the 12 Volts is in an alarm condition. | ||
| NTF trapPSDC5Volt | 1.3.6.1.4.1.1166.6.1.2.7.0.5 | This trap is issued when the 5 Voltage is in an alarm condition. | ||
| NTF trapPSDC3Volt | 1.3.6.1.4.1.1166.6.1.2.7.0.6 | This trap is issued when the 3.7 Voltage is in an alarm condition. | ||
| NTF trapPSDCAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.0.7 | This trap is issued when the Ambient Temperature is in an alarm condition. | ||
| NTF trapPSDCMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.0.8 | This trap is issued when the Main Temperature is in an alarm condition. | ||
| NTF trapPSDC12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.0.9 | This trap is issued when the 12 Anode Voltage is in an alarm condition. | ||
| NTF trapPSDC5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.0.10 | This trap is issued when the 5 Anode Voltage is in an alarm condition. | ||
| NTF trapPSDC3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.0.11 | This trap is issued when the 3 Anode Voltage is in an alarm condition. | ||
| NTF trapPSDCEEChksmAlarm | 1.3.6.1.4.1.1166.6.1.2.7.0.12 | This trap is issued when the Power Supply EEPROM Factory data CRC fails. | ||
| NTF trapPSDCFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.7.0.13 | This trap is issued when the embedded board flash has a problem. | ||
| NTF trapPSDCBootAlarm | 1.3.6.1.4.1.1166.6.1.2.7.0.14 | This trap is issued when the Module Boot from either bank fails. | ||
| NTF trapPSDCAlarmReportingStatus | 1.3.6.1.4.1.1166.6.1.2.7.0.15 | This trap is issued when the Alarm reporting is turned off. | ||
| NTF trapPSbrickType | 1.3.6.1.4.1.1166.6.1.2.7.0.16 | This trap is issued when power supply brick type is not a valid type. | ||
| NTF trapPSsupplyFailure | 1.3.6.1.4.1.1166.6.1.2.7.0.17 | This trap is issued when power supply fail condition occurs. (+12V , +5.1V, or _3.7V anode voltage out of spec.) | ||
| NTF trapPSDCALARMChksmAlarm | 1.3.6.1.4.1.1166.6.1.2.7.0.18 | This trap is issued when the Power Supply Alarm Data CRC check fails. | ||
| gx2PsdcDescriptor | 1.3.6.1.4.1.1166.6.1.2.7.1 | |||
| gx2PsdcAnalogTable | 1.3.6.1.4.1.1166.6.1.2.7.2 | not-accessible | This table contains gx2Psdc specific parameters with nominal and current values. | |
| gx2PsdcAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.7.2.1 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2PsdcAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.7.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR pslabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR psuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO psmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number |
| FLO psmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number |
| FLO psminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.8 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO psminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.10 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.11 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.7.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR pslabel12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.13 | DisplayString | read-only | The value of this object provides the label of the 12 Volt Analog parameter. |
| STR psuom12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.14 | DisplayString | read-only | The value of this object provides the unit of measure of the 12 Volt Analog parameter. |
| FLO psmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.19 | Float | read-only | The value of this object provides the Current value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.20 | INTEGER | read-only | The value of this object provides the state of the 12 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO psminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.21 | Float | read-only | The value of this object provides the minimum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.22 | Float | read-only | The value of this object provides the maximum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12 Volt Analog parameter. |
| STR pslabel5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Attenuator Setting Analog parameter. |
| STR psuom5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 5 Volt Analog parameter. |
| FLO psmajorHigh5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLow5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHigh5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLow5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValue5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.30 | Float | read-only | The value of this object provides the Current value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlag5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.31 | INTEGER | read-only | The value of this object provides the state of the 5 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO psminValue5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.32 | Float | read-only | The value of this object provides the minimum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValue5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.33 | Float | read-only | The value of this object provides the maximum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmState5Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the 5 Volt Analog parameter. |
| STR pslabel3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.35 | DisplayString | read-only | The value of this object provides the label of the 3 Anode Volt Analog parameter. |
| STR psuom3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 3.7V anode voltage analog parameter. |
| FLO psmajorHigh3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLow3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHigh3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLow3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValue3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.41 | Float | read-only | The value of this object provides the Current value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlag3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.42 | INTEGER | read-only | The value of this object provides the state of the 3 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO psminValue3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.43 | Float | read-only | The value of this object provides the minimum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValue3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.44 | Float | read-only | The value of this object provides the maximum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmState3Volt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the 3.7V anode voltage analog parameter. |
| STR pslabelAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Ambient Temperature Current Analog parameter. |
| STR psuomAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Ambient Temperature Analog parameter. |
| FLO psmajorHighAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLowAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHighAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLowAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValueAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.52 | Float | read-only | The value of this object provides the Current value of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlagAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Ambient Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO psminValueAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.54 | Float | read-only | The value of this object provides the minimum value the Ambient Temperature Analog parameter can achive. |
| FLO psmaxValueAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.55 | Float | read-only | The value of this object provides the maximum value the Ambient Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmStateAmbientTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Ambient Temperature Analog parameter. |
| STR pslabelMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Main Board Temperature Analog parameter. |
| STR psuomMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Main Board Temperature Analog parameter.. |
| FLO psmajorHighMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Main Board Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLowMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Main Board Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHighMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Main Board Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLowMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Main Board Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValueMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.63 | Float | read-only | The value of this object provides the Current value of the Main Board Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlagMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Main Board Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO psminValueMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.65 | Float | read-only | The value of this object provides the minimum value the Main Board Temperature Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValueMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.66 | Float | read-only | The value of this object provides the maximum value the Main Board Temperature Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmStateMainTemp | 1.3.6.1.4.1.1166.6.1.2.7.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Main Board Temperature Analog parameter. |
| STR pslabel12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.68 | DisplayString | read-only | The value of this object provides the label of the +12 Anode Voltage Analog parameter. |
| STR psuom12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the +12 Anode Voltage Analog parameter. |
| FLO psmajorHigh12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the +12V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLow12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the +12V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHigh12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the +12V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLow12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the +12V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValue12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.74 | Float | read-only | The value of this object provides the Current value of the +12V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlag12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.75 | INTEGER | read-only | The value of this object provides the state of the +12V anode voltage analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO psminValue12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.76 | Float | read-only | The value of this object provides the minimum value the +12V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValue12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.77 | Float | read-only | The value of this object provides the maximum value the +12V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmState12AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the +12V anode voltage analog parameter. |
| STR pslabel5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR psuom5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 5 Anode Volt Analog parameter. |
| FLO psmajorHigh5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the 5V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLow5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the 5V anode volt analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHigh5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the 5V anode volt analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLow5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the 5V anode volt analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValue5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.85 | Float | read-only | The value of this object provides the Current value of the 5V anode volt analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlag5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.86 | INTEGER | read-only | The value of this object provides the state of the 5 Anode Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO psminValue5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.87 | Float | read-only | The value of this object provides the minimum value the 5V anode volt analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValue5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.88 | Float | read-only | The value of this object provides the maximum value the 5V anode volt analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmState5AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the 5V anode voltage analog parameter. |
| STR pslabel3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.90 | DisplayString | read-only | The value of this object provides the label of the 3.7V anode voltage parameter. |
| STR psuom3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 3.7V anode voltage parameter. |
| FLO psmajorHigh3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value for the 3.7V anode voltage parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmajorLow3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value for the 3.7V anode voltage parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorHigh3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value for the 3.7V anode voltage parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psminorLow3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value for the 3.7V anode voltage parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO pscurrentValue3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.96 | Float | read-only | The value of this object provides the Current value of the 3.7V anode voltage parameter. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psstateFlag3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.97 | INTEGER | read-only | The value of this object provides the state of the 3.7V anode voltage parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO psminValue3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.98 | Float | read-only | The value of this object provides the minimum value that 3.7V anode voltage parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| FLO psmaxValue3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.99 | Float | read-only | The value of this object provides the maximum value that 3.7V anode voltage parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number. |
| INT psalarmState3AnodeVolt | 1.3.6.1.4.1.1166.6.1.2.7.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the 3.7V anode voltage parameter. |
| gx2PsdcStatusTable | 1.3.6.1.4.1.1166.6.1.2.7.3 | not-accessible | This table contains gx2Psdc specific parameters with nominal and current values. | |
| gx2PsdcStatusEntry | 1.3.6.1.4.1.1166.6.1.2.7.3.2 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2PsdcStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.7.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR pslabelBoot | 1.3.6.1.4.1.1166.6.1.2.7.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT psvalueBoot | 1.3.6.1.4.1.1166.6.1.2.7.3.2.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT psstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.7.3.2.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR pslabelFlash | 1.3.6.1.4.1.1166.6.1.2.7.3.2.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT psvalueFlash | 1.3.6.1.4.1.1166.6.1.2.7.3.2.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT psstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.7.3.2.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR pslabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.7.3.2.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT psvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.7.3.2.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT psstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.7.3.2.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR pslabelPsdcDataCRC | 1.3.6.1.4.1.1166.6.1.2.7.3.2.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT psvaluePsdcDataCRC | 1.3.6.1.4.1.1166.6.1.2.7.3.2.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT psstateflagPsdcDataCRC | 1.3.6.1.4.1.1166.6.1.2.7.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR pslabelPsdcHwStatus | 1.3.6.1.4.1.1166.6.1.2.7.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Hw Status parameter. |
| INT psvaluePsdcHwStatus | 1.3.6.1.4.1.1166.6.1.2.7.3.2.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT psstateflagPsdcHwStatus | 1.3.6.1.4.1.1166.6.1.2.7.3.2.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2PsdcFactoryTable | 1.3.6.1.4.1.1166.6.1.2.7.4 | not-accessible | This table contains gx2Psdc specific parameters with nominal and current values. | |
| gx2PsdcFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.7.4.3 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2PsdcFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.7.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT psbootControlByteValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. Boot Control Byte bit definition as follows : bit 0 : boot bit (0=boot from bank 0, 1=boot from bank 1) bit 1 : bank 0 status (0=bank is blank/bad, 1=bank is OK) bit 2 : bank 1 status (0=bank is blank/bad, 1=bank is OK) bits 3-7 : not used |
| INT psbootStatusByteValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.3 | INTEGER | read-only | This object indicates the status of the last boot Boot Status Byte bit definitions as follows: bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed boot) bit 1 : bank 1 status (0=bank is OK or not used, 1=bank failed boot) bit 2 : active bank (0=bank 0 active, 1=bank 1 active) bits 3-7: not used |
| INT psbank1CRCValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT psbank2CRCValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT psprgEEPROMByteValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT psfactoryCRCValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT pscalculateCRCValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. Calculate CRC command defintions as follows : 0x00 : recalculate factory data CRC 0x02 : recalculate alarm data CRC other values not defined |
| INT pshourMeterValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT psflashPrgCntAValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT psflashPrgCntBValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR psflashBankARevValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.12 | DisplayString | read-only | This object provides the CRC code of bank 0. The value is best displayed in Hex format |
| STR psflashBankBRevValue | 1.3.6.1.4.1.1166.6.1.2.7.4.3.13 | DisplayString | read-only | This object provides the CRC code of bank 1. The value is best displayed in Hex format |
| gx2PsdcHoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.7.5 | not-accessible | This table contains gx2Psdc specific parameters with nominal and current values. | |
| gx2PsdcHoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.7.5.4 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT rxgx2PsdcHoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.7.5.4.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT rxgx2PsdcHoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.7.5.4.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT rxgx2PsdcHoldTimeData | 1.3.6.1.4.1.1166.6.1.2.7.5.4.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
| gx2PsdcDigitalTable | 1.3.6.1.4.1.1166.6.1.2.7.6 | not-accessible | This table contains gx2Psdc specific parameters with nominal and current values. | |
| gx2PsdcDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.7.6.5 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2PsdcDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.7.6.5.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR psdclabelNVfanAlrm | 1.3.6.1.4.1.1166.6.1.2.7.6.5.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR psdcenumNVfanAlrm | 1.3.6.1.4.1.1166.6.1.2.7.6.5.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT psdcvalueNVfanAlrm | 1.3.6.1.4.1.1166.6.1.2.7.6.5.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT psdcstateflagNVfanAlrm | 1.3.6.1.4.1.1166.6.1.2.7.6.5.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
RFC description
HFC network management MIB for OMNISTAR gx2PSDC power supply elements, including device descriptors and performance parameters.
Start monitoring General Instrument/Motorola HFC headend equipment with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.