OMNI-gx2EM-MIB :: minorHigh12Volt

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2EM-MIB › minorHigh12Volt

minorHigh12Volt

Module: OMNI-gx2EM-MIB

OID (symbolic): OMNI-gx2EM-MIB::minorHigh12Volt

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.30.2.1.105

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is minorHigh12Volt?

This reports the minor-high alarm threshold configured for the module's 12V Supply Current reading, as an IEEE 32-bit floating point number, a less severe warning level than majorHigh12VSupplyCurrent. An administrator uses it as an early warning that 12V Supply Current is trending high before it reaches the major threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.105
snmpwalk -v2c -c public <target> OMNI-gx2EM-MIB::minorHigh12Volt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.105.1
snmpget -v2c -c public <target> OMNI-gx2EM-MIB::minorHigh12Volt.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EM-MIB::minorHigh12Volt OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.30gx2Em1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.30.2gx2emAnalogTableOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1gx2emAnalogEntryOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1.105minorHigh12VoltOMNI-gx2EM-MIB