| OID symbolic | OID numeric | Type | Access | Description |
| pbcGenericSystemMib | 1.3.6.1.4.1.5987.1.1.1 | | | This module defines management objects which are
common to all PBC chassis/system products. |
| pbcGeneric | 1.3.6.1.4.1.5987.2.1 | | | |
| pbcChassis | 1.3.6.1.4.1.5987.2.1.1 | | | |
| U32 pbcChassisEntityIndex | 1.3.6.1.4.1.5987.2.1.1.1 | Unsigned32 | read-only | entPhysicalIndex of the chassis' entry in the Entity MIB's
(RFC2737) entPhysicalTable or '0', if none. |
| INT pbcChassisOperStatus | 1.3.6.1.4.1.5987.2.1.1.2 | INTEGER | read-only | Chassis' current operational status. |
| U32 pbcChassisSlots | 1.3.6.1.4.1.5987.2.1.1.3 | Unsigned32 | read-only | Number of slots in this chassis, or '0' if
neither applicable nor determinable. |
| STR pbcContactInfo | 1.3.6.1.4.1.5987.2.1.1.4 | DisplayString | read-only | Pacific Broadband contact information. |
| STR pbcHostName | 1.3.6.1.4.1.5987.2.1.1.5 | DisplayString | read-write | Name of this system. |
| STR pbcDomainName | 1.3.6.1.4.1.5987.2.1.1.6 | DisplayString | read-write | Domain name for this host. |
| DAT pbcDateTimeOfLastChange | 1.3.6.1.4.1.5987.2.1.1.7 | DateAndTime | read-only | Date and time of last change to either the
configuration or the software. |
| U32 pbcCardIfIndexTableNumEntries | 1.3.6.1.4.1.5987.2.1.1.8 | Unsigned32 | read-only | Number of entries currently in the
pbcCardIfIndexTable. This should be the
same number as there are entries
in the ifTable. |
| pbcCardIfIndexTable | 1.3.6.1.4.1.5987.2.1.1.9 | | not-accessible | For each ifIndex currently exposed by the system,
this table will provide an association to the
physical and logical objects which are related to
it. |
| pbcCardIfIndexEntry | 1.3.6.1.4.1.5987.2.1.1.9.1 | | not-accessible | One ifIndex mapping entry. |
| U32 pbcCardIfCardIndex | 1.3.6.1.4.1.5987.2.1.1.9.1.1 | Unsigned32 | read-only | Index of the card in the Chassis
pbcCardTable which contains this interface
or '0' if not applicable. |
| U32 pbcCardIfPortNumber | 1.3.6.1.4.1.5987.2.1.1.9.1.2 | Unsigned32 | read-only | Chassis port number, unique per port on a given
card for the same interface type. If pbcCardIfPortNumber
is not applicable to the card, then the object instance
won't be populated. |
| POR pbcCardIfPortType | 1.3.6.1.4.1.5987.2.1.1.9.1.3 | PortType | read-only | The type of port associated with this ifIndex:
0 = Not Applicable
1 = Downstream
2 = Upstream
3 = Fast Ethernet
4 = Gigabit Ethernet
5 = 10 Gigabit Ethernet
6 = RS-232 |
| U32 pbcCardIfSlotNumber | 1.3.6.1.4.1.5987.2.1.1.9.1.4 | Unsigned32 | read-only | Chassis slot number, or '0' if neither
applicable nor determinable. |
| U32 pbcCardIfPortIndex | 1.3.6.1.4.1.5987.2.1.1.9.1.5 | Unsigned32 | read-only | The system unique port index number for the
physical port associated with this ifIndex. |
| U32 pbcCardTableNumEntries | 1.3.6.1.4.1.5987.2.1.1.10 | Unsigned32 | read-only | Number of entries currently in the pbcCardTable. |
| pbcCardTable | 1.3.6.1.4.1.5987.2.1.1.11 | | not-accessible | Chassis card table. |
| pbcCardEntry | 1.3.6.1.4.1.5987.2.1.1.11.1 | | not-accessible | Installed card types are enumerated here. These entries should not be
removed when a card is ejected from the system. The pbcCardOperStatus of
the ejected cards should be set to notPreset (8). |
| U32 pbcCardSlotNumber | 1.3.6.1.4.1.5987.2.1.1.11.1.1 | Unsigned32 | read-only | Slot number relative to the containing card or
chassis, or '0' if neither applicable nor
determinable. |
| U32 pbcCardEntityIndex | 1.3.6.1.4.1.5987.2.1.1.11.1.2 | Unsigned32 | read-only | entPhysicalIndex of this card's entry in the Entity MIB's
(RFC2737) entPhysicalTable or '0', if none. |
| INT pbcCardAdminStatus | 1.3.6.1.4.1.5987.2.1.1.11.1.3 | INTEGER | read-write | The desired state of the card. When a card/module
initializes, its initial pbcCardAdminStatus is down(2).
As a result of either explicit management action or
per configuration information retained by the managed
system, pbcCardAdminStatus is then changed to either the
up(1) or testing(3) states (or remains in the down(2)
state).
If a management application writes reset(4) to this
object, the card will initiate a full re-initialization. |
| INT pbcCardOperStatus | 1.3.6.1.4.1.5987.2.1.1.11.1.4 | INTEGER | read-only | The operational status of the card. The pbcCardOperStatus is operational(2)
when a card is recognized by the device and is enabled for operation.
pbcCardOperStatus is disabled(3) if the card is not recognized by the
device, or if it is not enabled for operation. pbcCardOperStatus is
standby(4) if the card is enabled and acting as a standby/redundant
slave. pbcCardOperStatus is testing (5) when the card is in the
diagnostic mode. pbcCardOperStatus is failure (6) if a hardware or
software failure is recognized. pbcCardOperStatus is initializing (7)
when the card is booting up and not ready to accept any external c
onfiguration. pbcCardOperStatus is notPresent (8) if the card has been
removed from the system. |
| TIK pbcCardUpTime | 1.3.6.1.4.1.5987.2.1.1.11.1.5 | TimeTicks | read-only | The value of sysUpTime for this management
entity, when this card was last (re-)initialized. |
| U32 pbcCardnvRAMSize | 1.3.6.1.4.1.5987.2.1.1.11.1.6 | Unsigned32 | read-only | Amount of non-volatile RAM in bytes. |
| U32 pbcCardNumPorts | 1.3.6.1.4.1.5987.2.1.1.11.1.7 | Unsigned32 | read-only | Number of ports on this card, or '0' if no
ports or not applicable or determinable. |
| INT pbcCardType | 1.3.6.1.4.1.5987.2.1.1.11.1.8 | INTEGER | read-only | The card type of the card.
Here are the various types of cards supported:
ccm -Chassis Control Module
dm - DOCSIS Module
nic - Network Interface Module
rim - Redundant Rear I/O Module
sim - Switching Rear I/O Module
There may be one or two cards in one slot - one in front and the
other in the rear of the midplane. |
| INT pbcCardPosition | 1.3.6.1.4.1.5987.2.1.1.11.1.9 | INTEGER | read-only | The position of the card relative to the midplane. The pbcCardTable may
contain one or two entry per slot. If there are two entries present
per slot, then the pbcCardPosition of one should have the value
front (2) and the other should have the value rear (2). |
| pbcCardPortTable | 1.3.6.1.4.1.5987.2.1.1.12 | | not-accessible | Describes the ports on a particular card and their
current status. |
| pbcCardPortEntry | 1.3.6.1.4.1.5987.2.1.1.12.1 | | not-accessible | Port characteristics comprising an entry in the table. These entries should not be
removed when a card is ejected from the system. The pbcCardPortStatus of
the ejected cards should be set to notPreset (5). |
| INT pbcCardPortStatus | 1.3.6.1.4.1.5987.2.1.1.12.1.1 | INTEGER | read-only | The current operational status of this port. pbcCardPortStatus is
active(2) when a port is enabled for operation. pbcCardPortStatus is
disabled(3) if the port is not enabled for operation. pbcCardPortStatus
is standby(4) if the port is on a card is acting as a standby. The
pbcCardPortStatus is not-present(5) if the card containing the port
has been removed from the system. |
| U32 pbcCardPortEntityIndex | 1.3.6.1.4.1.5987.2.1.1.12.1.2 | Unsigned32 | read-only | entPhysicalIndex of this port's entry in the Entity MIB's
(RFC2737) entPhysicalTable or '0', if none. |
| STR pbcCardPortAlias | 1.3.6.1.4.1.5987.2.1.1.12.1.3 | DisplayString | read-write | Alias name for the port as specified by a network manager. On the first
instantiation of the interface, the value of the pbcCardPortAlias is
zero-length string. When a value is written into an instance of the
pbcCardPortAlias through a set operation, then the agent must retain
the supplied value as long as the port remains instantiated, including
across all re-initializations and reboots of the system. |
| pbcPortIfTable | 1.3.6.1.4.1.5987.2.1.1.13 | | not-accessible | Lists the interfaces (ifIndex values) associated with
a specific port. |
| pbcPortIfEntry | 1.3.6.1.4.1.5987.2.1.1.13.1 | | not-accessible | An entry in the pbcPortIfEntry table. For each port
number within the system, assigned by the chassis CCM,
there is one entry for each IfIndex associated with
that port. If no interfaces are associated with
this port, then an entry with a portIfIndex value
of -1 will appear in this table. |
| NUM pbcPortIfIndex | 1.3.6.1.4.1.5987.2.1.1.13.1.1 | InterfaceIndex | read-only | ifIndex associated with this port or '-1',
if none. |
| pbcGenericConformance | 1.3.6.1.4.1.5987.2.1.2 | | | |
| pbcGenericGroups | 1.3.6.1.4.1.5987.2.1.2.1 | | | |
| pbcChassisGroup | 1.3.6.1.4.1.5987.2.1.2.1.1 | | | Objects associated with generic PBC
chassis management. |
| pbcGenericCompliance | 1.3.6.1.4.1.5987.2.1.2.2 | | | |
| pbcGenericBasicCompliance | 1.3.6.1.4.1.5987.2.1.2.2.1 | | | Group support required for basic level compliance. |