OMNI-gx2EM-MIB :: currentValueTecCurrent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2EM-MIB › currentValueTecCurrent

currentValueTecCurrent

Module: OMNI-gx2EM-MIB

OID (symbolic): OMNI-gx2EM-MIB::currentValueTecCurrent

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.30.2.1.63

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is currentValueTecCurrent?

This reports the module's current live reading for TEC (thermoelectric cooler) Current, as an IEEE 32-bit floating point number. An administrator polls this as the actual measured value to compare against the configured alarm thresholds for the same parameter. A steady drift in this reading over time, rather than a single reading, is usually what signals gradual hardware aging.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.63
snmpwalk -v2c -c public <target> OMNI-gx2EM-MIB::currentValueTecCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.30.2.1.63.1
snmpget -v2c -c public <target> OMNI-gx2EM-MIB::currentValueTecCurrent.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EM-MIB::currentValueTecCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM expansion module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.30gx2Em1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.30.2gx2emAnalogTableOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1gx2emAnalogEntryOMNI-gx2EM-MIB
1.3.6.1.4.1.1166.6.1.2.30.2.1.63currentValueTecCurrentOMNI-gx2EM-MIB