All MIBs › RFC1289-phivMIB
Category: IETF Standards
Description:
Defines DEC DECnet Phase IV network protocol management objects per RFC 1289.
Imported Objects
What Is RFC1289-phivMIB?
RFC1289-phivMIB is a vendor-neutral, standards-based IETF MIB defining management objects for DECnet Phase IV, Digital Equipment Corporation's proprietary network protocol suite, as specified in RFC 1289. It exposes DECnet-specific configuration and operational data such as node addressing, circuit status, and routing/adjacency information relevant to Phase IV networks. Its monitoring role is chiefly around software/protocol status: node reachability, circuit up/down state, and routing adjacency health on DECnet nodes rather than physical hardware sensors. It stands somewhat independently of TCP/IP-centric MIBs like MIB-II, being tailored to the separate DECnet protocol stack, though it follows the same SMI conventions for structuring. It would be deployed in legacy VAX/VMS or DECnet-based environments, largely of historical interest today as DECnet Phase IV networks have been phased out. Engineers implementing or auditing this functionality typically reference the RFC1289-phivMIB RFC/standard documentation for the authoritative specification.
IPNetwork Monitor allows you to monitor SNMP objects defined in RFC1289-phivMIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- DECnet node status
- circuit operational state
- routing/adjacency status
- node reachability
Supported Devices
- vendor-neutral, standards-based MIB, not tied to a specific manufacturer
- legacy DECnet Phase IV network nodes (historically DEC VAX/VMS systems)
Monitoring Examples
An administrator would poll DECnet node and circuit status objects to confirm a node is reachable and its circuits are operational, watching for a circuit transitioning to a down or off state. Persistent circuit-down conditions or routing adjacency loss would indicate a failed DECnet link between nodes in the network.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| phiv | 1.3.6.1.2.1.18 | |||
| phivSystem | 1.3.6.1.2.1.18.1 | |||
| INT phivSystemState | 1.3.6.1.2.1.18.1.1 | INTEGER | read-write | This represents the operational state of the executor node. The possible states are: ON Allows logical links. OFF Allows no new links, terminates existing links, and stops routing traffic through. SHUT Allows no new logical links, does not destroy existing logical links, and goes to the OFF state when all logical links are gone. RESTRICTED Allows no new incoming logical links from other nodes. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155). |
| STR phivExecIdent | 1.3.6.1.2.1.18.1.2 | DisplayString | read-write | This is a text string that describes the executor node (for example, 'Research Lab'). The string is up to 32 characters of any type. |
| phivManagement | 1.3.6.1.2.1.18.2 | |||
| STR phivMgmtMgmtVers | 1.3.6.1.2.1.18.2.1 | DisplayString | read-only | This is the read-only Network Management Version, consisting of the version number, the Engineering Change Order (ECO) number, and the user ECO number (for example, 3.0.0). This parameter applies to the executor node only. |
| session | 1.3.6.1.2.1.18.3 | |||
| STR phivSessionSystemName | 1.3.6.1.2.1.18.3.1 | DisplayString | read-only | Name to be associated with the node identification. Only one name can be assigned to a node address or a circuit identification. No name should be used more than once in a DECnet network. Node-name is one to six upper case alphanumeric characters with at least one alpha character. A length of 0 indicates no name. |
| INT phivSessionInTimer | 1.3.6.1.2.1.18.3.2 | INTEGER | read-write | This value represents the maximum duration between the time a connect is received for a process at the executor node and the time that process accepts or rejects it. If the connect is not accepted or rejected by the user within the number of seconds specified, Session Control rejects it for the user. A 0 indicates no timer is running. |
| INT phivSessionOutTimer | 1.3.6.1.2.1.18.3.3 | INTEGER | read-write | This value represents the duration between the time the executor requests a connect and the time that connect is acknowledged by the destination node. If the connect is not acknowledged within the number of seconds specified, Session Control returns an error. A 0 indicates no timer is running. |
| end | 1.3.6.1.2.1.18.4 | |||
| phivEndRemoteTable | 1.3.6.1.2.1.18.4.1 | not-accessible | Information about the state of sessions between the node under study and the nodes found in the table. | |
| phivEndRemoteEntry | 1.3.6.1.2.1.18.4.1.1 | not-accessible | Information about a particular remote node as seen from the end communication layer. | |
| PHI phivEndRemoteHostNodeID | 1.3.6.1.2.1.18.4.1.1.1 | PhivAddr | read-only | This value is the address of the remote node to be evaluated. |
| INT phivEndRemoteState | 1.3.6.1.2.1.18.4.1.1.2 | INTEGER | read-write | This represents the operational state of the remote node being evaluated. The possible states are: ON Allows logical links. OFF Allows no new links, terminates existing links, and stops routing traffic through. SHUT Allows no new logical links, does not destroy existing logical links, and goes to the OFF state when all logical links are gone. RESTRICTED Allows no new incoming logical links from other nodes. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155. |
| INT phivEndCircuitIndex | 1.3.6.1.2.1.18.4.1.1.3 | INTEGER | read-only | A unique index value for each known circuit used to communicate with the remote node. This is the same value as phivCircuitIndex. |
| INT phivEndActiveLinks | 1.3.6.1.2.1.18.4.1.1.4 | INTEGER | read-only | This read-only parameter represents the number of active logical links from the executor to the destination node. |
| INT phivEndDelay | 1.3.6.1.2.1.18.4.1.1.5 | INTEGER | read-only | This read-only parameter is the average round trip delay in seconds to the destination node. This parameter is kept on a remote node basis. |
| phivEndCountTable | 1.3.6.1.2.1.18.4.2 | not-accessible | Information about the counters associated with each end system that is known to the entity. These counters reflect totals from the perspective of the executor node. | |
| phivEndCountEntry | 1.3.6.1.2.1.18.4.2.1 | not-accessible | Information about a particular session between two end systems. | |
| PHI phivEndCountHostNodeID | 1.3.6.1.2.1.18.4.2.1.1 | PhivAddr | read-only | This value is the address of the remote node to be evaluated. |
| NUM phivEndCountSecsLastZeroed | 1.3.6.1.2.1.18.4.2.1.2 | PhivCounter | read-only | This value is the number of seconds that have elapsed since the counters for the node in this table row were last set to zero. This counter is located in the network management layer, but is returned with the end system information which follows. |
| NUM phivEndCountUsrBytesRec | 1.3.6.1.2.1.18.4.2.1.3 | PhivCounter | read-only | Number of user bytes received from the target host. |
| NUM phivEndCountUsrBytesSent | 1.3.6.1.2.1.18.4.2.1.4 | PhivCounter | read-only | Number of user bytes sent to the target host. |
| NUM phivEndUCountUsrMessRec | 1.3.6.1.2.1.18.4.2.1.5 | PhivCounter | read-only | Number of user messages received from the target host. |
| NUM phivEndCountUsrMessSent | 1.3.6.1.2.1.18.4.2.1.6 | PhivCounter | read-only | Number of user messages sent to the target host. |
| NUM phivEndCountTotalBytesRec | 1.3.6.1.2.1.18.4.2.1.7 | PhivCounter | read-only | Number of bytes received from the target host. |
| NUM phivEndCountTotalBytesSent | 1.3.6.1.2.1.18.4.2.1.8 | PhivCounter | read-only | Number of bytes sent to the target host. |
| NUM phivEndCountTotalMessRec | 1.3.6.1.2.1.18.4.2.1.9 | PhivCounter | read-only | Number of messages received from the target host. |
| NUM phivEndCountTotalMessSent | 1.3.6.1.2.1.18.4.2.1.10 | PhivCounter | read-only | Number of messages sent to the target host. |
| NUM phivEndCountConnectsRecd | 1.3.6.1.2.1.18.4.2.1.11 | PhivCounter | read-only | Number of connects received from the target host. |
| NUM phivEndCountConnectsSent | 1.3.6.1.2.1.18.4.2.1.12 | PhivCounter | read-only | Number of connects sent to the target host. |
| NUM phivEndCountReponseTimeouts | 1.3.6.1.2.1.18.4.2.1.13 | PhivCounter | read-only | Number of response timeouts. |
| NUM phivEndCountRecdConnectResErrs | 1.3.6.1.2.1.18.4.2.1.14 | PhivCounter | read-only | Number of received connect resource errors. |
| INT phivEndMaxLinks | 1.3.6.1.2.1.18.4.3 | INTEGER | read-write | This value represents the maximum active logical link count allowed for the executor. |
| STR phivEndNSPVers | 1.3.6.1.2.1.18.4.4 | DisplayString | read-only | This read-only parameter represents the version number of the node End Communication S/W. The format is version number, ECO, and user ECO, e.g., 4.1.0 |
| INT phivEndRetransmitFactor | 1.3.6.1.2.1.18.4.5 | INTEGER | read-write | This value represents the maximum number of times the source End Communication at the executor node will restart the retransmission timer when it expires. If the number is exceeded, Session Control disconnects the logical link for the user. |
| INT phivEndDelayFact | 1.3.6.1.2.1.18.4.6 | INTEGER | read-write | This is the number by which to multiply one sixteenth of the estimated round trip delay to a node to set the retransmission timer to that node. |
| INT phivEndDelayWeight | 1.3.6.1.2.1.18.4.7 | INTEGER | read-write | This number represents the weight to apply to a current round trip delay estimate to a remote node when updating the estimated round trip delay to a node. On some systems the number must be 1 less than a power of 2 for computational efficiency. |
| INT phivEndInactivityTimer | 1.3.6.1.2.1.18.4.8 | INTEGER | read-write | This value represents the maximum duration of inactivity (no data in either direction) on a logical link before the node checks to see if the logical link still works. If no activity occurs within the minimum number of seconds, End Communication generates artificial traffic to test the link (End Communication specification). |
| INT phivEndCountZeroCount | 1.3.6.1.2.1.18.4.9 | INTEGER | read-write | When this value is set to 2, all of the counters in the End System Counter Table are set to zero. |
| NUM phivEndMaxLinksActive | 1.3.6.1.2.1.18.4.10 | PhivCounter | read-write | This value represents the high water mark for the number of links that were active at any one time. |
| routing | 1.3.6.1.2.1.18.5 | |||
| INT phivRouteBroadcastRouteTimer | 1.3.6.1.2.1.18.5.1 | INTEGER | read-write | This value determines the maximum time in seconds allowed between Routing updates on Ethernet circuits. When this timer expired before a routing update occurs, a routing update is forced. With a standard calculation, Routing also uses this timer to enforce a minimum delay between routing updates. |
| INT phivRouteBuffSize | 1.3.6.1.2.1.18.5.2 | INTEGER | read-write | This parameter value determines the maximum size of a Routing message. It therefore determines the maximum size message that can be forwarded. This size includes protocol overhead down to and including the End Communication layer, plus a constant value of 6. (This value of 6 is included to provide compatibility with the parameter definition in Phase III, which included the Routing overhead.) It does not include Routing or Data link overhead (except for the constant value of 6). There is one buffer size for all circuits. NOTE: The BUFFER SIZE defines the maximum size messages that the Routing layer can forward. The SEGMENT BUFFER SIZE (defined below) defines the maximum size messages that the End Communication layer can transmit or receive. The SEGMENT BUFFER SIZE is always less than or equal to the BUFFER SIZE. Normally the two parameters will be equal. They may be different to allow the network manager to alter buffer sizes on all nodes without interruption of service. They both include an extra 6 bytes for compatibility with Phase III. |
| STR phivRouteRoutingVers | 1.3.6.1.2.1.18.5.3 | DisplayString | read-only | This read-only parameter identifies the executor node's Routing version number. The format is version number, ECO, and user ECO, e.g., 4.1.0 |
| INT phivRouteMaxAddr | 1.3.6.1.2.1.18.5.4 | INTEGER | read-write | This value represents the largest node number and, therefore, number of nodes that can be known about by the executor node's home area. |
| INT phivRouteMaxBdcastNonRouters | 1.3.6.1.2.1.18.5.5 | INTEGER | read-write | This value represents the maximum total number of nonrouters the executor node can have on its Ethernet circuits. |
| INT phivRouteMaxBdcastRouters | 1.3.6.1.2.1.18.5.6 | INTEGER | read-write | This value represents the maximum total number of routers the executor node can have on its Ethernet circuits. |
| INT phivRouteMaxBuffs | 1.3.6.1.2.1.18.5.7 | INTEGER | read-write | This value represents the maximum number of transmit buffers that Routing may use for all circuits. |
| INT phivRouteMaxCircuits | 1.3.6.1.2.1.18.5.8 | INTEGER | read-write | This value represents the maximum number of Routing circuits that the executor node can know about. |
| INT phivRouteMaxCost | 1.3.6.1.2.1.18.5.9 | INTEGER | read-write | This value represents the maximum total path cost allowed from the executor to any node within an area. The path cost is the sum of the circuit costs along a path between two nodes. This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the cost of the least costly path to the other node is excessive. For correct operation, this parameter must not be less than the maximum path cost of the network. |
| INT phivRouteMaxHops | 1.3.6.1.2.1.18.5.10 | INTEGER | read-write | This value represents the maximum number of routing hops allowable from the executor to any other reachable node within an area. (A hop is the logical distance over a circuit between two adjacent nodes.) This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the length of the shortest path between the two nodes is too long. For correct operation, this parameter must not be less than the network diameter. (The network diameter is the reachability distance between the two nodes of the network having the greatest reachability distance, where reachability distance is the length the shortest path between a given pair of nodes.) |
| INT phivRouteMaxVisits | 1.3.6.1.2.1.18.5.11 | INTEGER | read-write | This value represents the maximum number of nodes a message coming into the executor node can have visited. If the message is not for this node and the MAXIMUM VISITS number is exceeded, the message is discarded. The MAXIMUM VISITS parameter defines the point where the packet lifetime control algorithm discards a packet that has traversed too many nodes. For correct operation, this parameter must not be less than the maximum path length of the network. (The maximum path length is the routing distance between the two nodes of the network having the greatest routing distance, where routing distance is the length of the least costly path between a given pair of nodes.) |
| INT phivRouteRoutingTimer | 1.3.6.1.2.1.18.5.12 | INTEGER | read-write | This value determines the maximum time in seconds allowed between Routing updates on non-Ethernet circuits. When this timer expires before a routing update occurs, a routing update is forced. |
| INT phivRouteSegBuffSize | 1.3.6.1.2.1.18.5.13 | INTEGER | read-write | This parameter value determines the maximum size of an end-to-end segment. The size is a decimal integer in the range 1-65535. This size is in bytes. This size includes protocol overhead down to and including the End Communication layer, plus a constant value of 6. (This value of 6 is included to provide compatibility with the BUFFER SIZE parameter definition.) It does not include Routing or Data link overhead (except for the constant value of 6). |
| INT phivRouteType | 1.3.6.1.2.1.18.5.14 | INTEGER | read-only | This parameter indicates the type of the executor node. The node-type is one of the following: routing-III nonrouting-III routing-IV ronrouting-IV area A routing node has full routing capability. A nonrouting node contains a subset of the Routing routing modules. The III and IV indicate the DNA phase of the node. Nonrouting nodes can deliver and receive packets to and from any node, but cannot route packets from other nodes through to other nodes. An area node routes between areas. Refer to the Routing specification for details. For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The ROUTING-III and NONROUTING-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155) |
| NUM phivRouteCountAgedPktLoss | 1.3.6.1.2.1.18.5.15 | PhivCounter | read-only | Number of aged packet losses. |
| NUM phivRouteCountNodeUnrPktLoss | 1.3.6.1.2.1.18.5.16 | PhivCounter | read-only | Number of node unreachable packet losses. |
| NUM phivRouteCountOutRngePktLoss | 1.3.6.1.2.1.18.5.17 | PhivCounter | read-only | Number of node out-of-range packet losses. |
| NUM phivRouteCountOverSzePktLoss | 1.3.6.1.2.1.18.5.18 | PhivCounter | read-only | Number of Oversized packet losses. |
| NUM phivRouteCountPacketFmtErr | 1.3.6.1.2.1.18.5.19 | PhivCounter | read-only | Number of packet format errors. |
| NUM phivRouteCountPtlRteUpdtLoss | 1.3.6.1.2.1.18.5.20 | PhivCounter | read-only | Number of partial routing update losses. |
| NUM phivRouteCountVerifReject | 1.3.6.1.2.1.18.5.21 | PhivCounter | read-only | Number of verification rejects. |
| phivLevel1RouteTable | 1.3.6.1.2.1.18.5.22 | not-accessible | Information about the currently known DECnet Phase IV Routes. | |
| phivLevel1RouteEntry | 1.3.6.1.2.1.18.5.22.1 | not-accessible | Information about the currently known DECnet Phase IV Routes. | |
| PHI phivLevel1RouteNodeAddr | 1.3.6.1.2.1.18.5.22.1.1 | PhivAddr | read-only | This value is the address of the node about which routing information is contained in this level 1 routing table. |
| INT phivLevel1RouteCircuitIndex | 1.3.6.1.2.1.18.5.22.1.2 | INTEGER | read-only | A unique index value for each known circuit. This is the index to the circuit state table and is the same value as phivCircuitIndex. |
| INT phivLevel1RouteCost | 1.3.6.1.2.1.18.5.22.1.3 | INTEGER | read-only | This read-only parameter represents the total cost over the current path to the destination node. Cost is a positive integer value associated with using a circuit. Routing routes messages (data) along the path between two nodes with the smallest cost. COST is kept on a remote node basis. |
| INT phivLevel1RouteHops | 1.3.6.1.2.1.18.5.22.1.4 | INTEGER | read-only | This read-only parameter represents the number of hops over to a destination node. A hop is Routing value representing the logical distance between two nodes in a network. HOPS is kept on a remote node basis. |
| PHI phivLevel1RouteNextNode | 1.3.6.1.2.1.18.5.22.1.5 | PhivAddr | read-only | This read-only value indicates the next node on the circuit used to get to the node under scrutiny (next hop). |
| INT phivRouteCountZeroCount | 1.3.6.1.2.1.18.5.23 | INTEGER | read-write | When this value is set to 2, the following objects are set to Zero: phivRouteCountAgedPktLoss, phivRouteCountNodeUnrPktLoss, phivRouteCountOutRngePktLoss, phivRouteCountOverSzePktLoss, phivRouteCountPacketFmtErr, phivRouteCountPtlRteUpdtLoss, and phivRouteCountVerifReject. |
| PHI phivRouteSystemAddr | 1.3.6.1.2.1.18.5.24 | PhivAddr | read-only | DECnet Phase IV node address. |
| circuit | 1.3.6.1.2.1.18.6 | |||
| phivCircuitParametersTable | 1.3.6.1.2.1.18.6.1 | not-accessible | Information about the parameters associated with all circuits currently known. | |
| phivCircuitParametersEntry | 1.3.6.1.2.1.18.6.1.1 | not-accessible | Parameters information about all circuits currently known. | |
| INT phivCircuitIndex | 1.3.6.1.2.1.18.6.1.1.1 | INTEGER | read-only | A unique index value for each known circuit. |
| INT phivCircuitLineIndex | 1.3.6.1.2.1.18.6.1.1.2 | INTEGER | read-only | The line on which this circuit is active. This is the same as the IfIndex. |
| INT phivCircuitCommonState | 1.3.6.1.2.1.18.6.1.1.3 | INTEGER | read-write | This value represents the circuit's Network Management operational state. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155. |
| INT phivCircuitCommonSubState | 1.3.6.1.2.1.18.6.1.1.4 | INTEGER | read-only | This value represents the circuit's Network Management operational and service substate. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155. |
| STR phivCircuitCommonName | 1.3.6.1.2.1.18.6.1.1.5 | DisplayString | read-only | The name of the circuit entry in the table, for example, SVA-0 or in a level 2 router ASYNC-8 or ETHER-1). |
| INT phivCircuitExecRecallTimer | 1.3.6.1.2.1.18.6.1.1.6 | INTEGER | read-write | This parameter represents the minimum number of seconds to wait before restarting the circuit. A value of 0 indicates not timer is running. |
| INT phivCircuitCommonType | 1.3.6.1.2.1.18.6.1.1.7 | INTEGER | read-only | Represents the type of the circuit. For X.25 circuits, the value must be set to X25. For DDCMP and Ethernet circuits it is read only and is the same value as the protocol of the associated line. NOTE: Values 1 - 5 are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155. |
| INT phivCircuitService | 1.3.6.1.2.1.18.6.1.1.8 | INTEGER | read-write | This value indicates whether or not Network Management allows service operations on a circuit. The values for service-control are as follows: ENABLED SERVICE state and/or service functions are allowed. DISABLED SERVICE state and/or service functions are not allowed. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155. |
| INT phivCircuitExecCost | 1.3.6.1.2.1.18.6.1.1.9 | INTEGER | read-write | This value represents the routing cost of the circuit. Routing sends messages along the path between two nodes having the smallest cost. |
| INT phivCircuitExecHelloTimer | 1.3.6.1.2.1.18.6.1.1.10 | INTEGER | read-write | This value determines the frequency of Routing Hello messages sent to the adjacent node on the circuit. |
| phivCircuitCountTable | 1.3.6.1.2.1.18.6.2 | not-accessible | Information about the counters associated with all circuits currently known. | |
| phivCircuitCountEntry | 1.3.6.1.2.1.18.6.2.1 | not-accessible | Counter information about all circuits currently known | |
| NUM phivCircuitCountSecLastZeroed | 1.3.6.1.2.1.18.6.2.1.1 | PhivCounter | read-only | Number of seconds since the circuit counters for this circuit were last zeroed. |
| NUM phivCircuitCountTermPacketsRecd | 1.3.6.1.2.1.18.6.2.1.2 | PhivCounter | read-only | Number of terminating packets received on this circuit. |
| NUM phivCircuitCountOriginPackSent | 1.3.6.1.2.1.18.6.2.1.3 | PhivCounter | read-only | Number of originating packets sent on this circuit. |
| NUM phivCircuitCountTermCongLoss | 1.3.6.1.2.1.18.6.2.1.4 | PhivCounter | read-only | Number of terminating congestion losses on this circuit. |
| NUM phivCircuitCountCorruptLoss | 1.3.6.1.2.1.18.6.2.1.5 | PhivCounter | read-only | Number of corruption losses on this circuit. |
| NUM phivCircuitCountTransitPksRecd | 1.3.6.1.2.1.18.6.2.1.6 | PhivCounter | read-only | Number of Transit packets received on this circuit. |
| NUM phivCircuitCountTransitPkSent | 1.3.6.1.2.1.18.6.2.1.7 | PhivCounter | read-only | Number of transit packets sent on this circuit. |
| NUM phivCircuitCountTransitCongestLoss | 1.3.6.1.2.1.18.6.2.1.8 | PhivCounter | read-only | Number of transit congestion losses on this circuit. |
| NUM phivCircuitCountCircuitDown | 1.3.6.1.2.1.18.6.2.1.9 | PhivCounter | read-only | Number of circuit downs on this circuit. |
| NUM phivCircuitCountInitFailure | 1.3.6.1.2.1.18.6.2.1.10 | PhivCounter | read-only | Number of Initialization failures on this circuit. |
| NUM phivCircuitCountAdjDown | 1.3.6.1.2.1.18.6.2.1.11 | PhivCounter | read-only | This counter indicates the number of adjacency losses that result from any of the following: Node listener timeout Invalid data received at node listener Unexpected control (initialization or verification) message received Routing message received with a checksum error Node identification from a routing message or a Hello message that is not the one expected Hello message received indicating that connectivity became one-way Adjacency idled. |
| NUM phivCircuitCountPeakAdj | 1.3.6.1.2.1.18.6.2.1.12 | PhivCounter | read-only | This counter indicates the maximum number of nodes that are up on the circuit. |
| NUM phivCircuitCountBytesRecd | 1.3.6.1.2.1.18.6.2.1.13 | PhivCounter | read-only | Number of bytes received on this circuit. |
| NUM phivCircuitCountBytesSent | 1.3.6.1.2.1.18.6.2.1.14 | PhivCounter | read-only | Number of bytes sent on this circuit. |
| NUM phivCircuitCountDataBlocksRecd | 1.3.6.1.2.1.18.6.2.1.15 | PhivCounter | read-only | Number of data blocks received on this circuit. |
| NUM phivCircuitCountDataBlocksSent | 1.3.6.1.2.1.18.6.2.1.16 | PhivCounter | read-only | Number of data blocks sent on this circuit. |
| NUM phivCircuitCountUsrBuffUnav | 1.3.6.1.2.1.18.6.2.1.17 | PhivCounter | read-only | Number of user buffer unavailable errors. |
| INT phivCircuitOrigQueueLimit | 1.3.6.1.2.1.18.6.3 | INTEGER | read-write | This parameter indicates the maximum number of originating packets that may be outstanding on this circuit. This does not include route-thru traffic. |
| INT phivCircuitCountZeroCount | 1.3.6.1.2.1.18.6.4 | INTEGER | read-write | When this value is set to 2, all of the counters in the Circuit Counter Table are set to zero. |
| ddcmp | 1.3.6.1.2.1.18.7 | |||
| phivDDCMPCircuitParametersTable | 1.3.6.1.2.1.18.7.1 | not-accessible | Information about DDCMP circuit parameters. | |
| phivDDCMPCircuitParametersEntry | 1.3.6.1.2.1.18.7.1.1 | not-accessible | Parameters information about DDCMP circuits currently known. | |
| INT phivDDCMPCircuitIndex | 1.3.6.1.2.1.18.7.1.1.1 | INTEGER | read-only | A unique index value for each known DDCMP circuit. This is the same value as phivCircuitIndex. |
| PHI phivDDCMPCircuitAdjNodeAddr | 1.3.6.1.2.1.18.7.1.1.2 | PhivAddr | read-only | The address of the adjacent node. |
| INT phivDDCMPCircuitTributary | 1.3.6.1.2.1.18.7.1.1.3 | INTEGER | read-only | This value represents the Data Link physical tributary address of the circuit. |
| phivDDCMPCircuitCountTable | 1.3.6.1.2.1.18.7.2 | not-accessible | Information about the DDCMP counters associated with all circuits currently known. | |
| phivDDCMPCircuitCountEntry | 1.3.6.1.2.1.18.7.2.1 | not-accessible | Counter information about DDCMP circuits now known | |
| NUM phivDDCMPCircuitErrorsInbd | 1.3.6.1.2.1.18.7.2.1.1 | PhivCounter | read-only | Number of Data errors inbound. |
| NUM phivDDCMPCircuitErrorsOutbd | 1.3.6.1.2.1.18.7.2.1.2 | PhivCounter | read-only | Number of outbound data errors. |
| NUM phivDDCMPCircuitRmteReplyTimeouts | 1.3.6.1.2.1.18.7.2.1.3 | PhivCounter | read-only | Number of remote reply timeouts. |
| NUM phivDDCMPCircuitLocalReplyTimeouts | 1.3.6.1.2.1.18.7.2.1.4 | PhivCounter | read-only | Number of local Reply timeouts. |
| NUM phivDDCMPCircuitRmteBuffErrors | 1.3.6.1.2.1.18.7.2.1.5 | PhivCounter | read-only | Number of remote reply time out errors. |
| NUM phivDDCMPCircuitLocalBuffErrors | 1.3.6.1.2.1.18.7.2.1.6 | PhivCounter | read-only | Number of local buffer errors. |
| NUM phivDDCMPCircuitSelectIntervalsElap | 1.3.6.1.2.1.18.7.2.1.7 | PhivCounter | read-only | Selection intervals that have elapsed. |
| NUM phivDDCMPCircuitSelectTimeouts | 1.3.6.1.2.1.18.7.2.1.8 | PhivCounter | read-only | Number of selection timeouts. |
| phivDDCMPLineCountTable | 1.3.6.1.2.1.18.7.3 | not-accessible | The DDCMP Line Count Table. | |
| phivDDCMPLineCountEntry | 1.3.6.1.2.1.18.7.3.1 | not-accessible | There is one entry in the table for each line. | |
| INT phivDDCMPLineCountIndex | 1.3.6.1.2.1.18.7.3.1.1 | INTEGER | read-only | The line on which this entry's equivalence is effective. The interface identified by a particular value of this index is the same interface as identified by the same value of phivLineIndex. This value is the IfIndex. |
| NUM phivDDCMPLineCountDataErrsIn | 1.3.6.1.2.1.18.7.3.1.2 | PhivCounter | read-only | Number of data errors inbound. |
| NUM phivDDCMPLineCountRmteStationErrs | 1.3.6.1.2.1.18.7.3.1.3 | PhivCounter | read-only | Number of remote station errors. |
| NUM phivDDCMPLineCountLocalStationErrs | 1.3.6.1.2.1.18.7.3.1.4 | PhivCounter | read-only | Number of local station errors. |
| control | 1.3.6.1.2.1.18.8 | |||
| INT phivControlSchedTimer | 1.3.6.1.2.1.18.8.1 | INTEGER | read-only | This value represents the number of milliseconds between recalculation of tributary polling priorities. |
| INT phivControlDeadTimer | 1.3.6.1.2.1.18.8.2 | INTEGER | read-only | This value represents the number of milliseconds between polls of one of the set of dead tributaries. |
| INT phivControlDelayTimer | 1.3.6.1.2.1.18.8.3 | INTEGER | read-only | This value represents the minimum number of milliseconds to delay between polls. The delay timer limits the effect of a very fast control station on slow tributaries. |
| INT phivControlStreamTimer | 1.3.6.1.2.1.18.8.4 | INTEGER | read-only | This value represents the number of milliseconds a tributary or a half duplex remote station is allowed to hold the line. NOTE: This parameter can also be applied to half-duplex lines of type DDCMP POINT. |
| phivControlParametersTable | 1.3.6.1.2.1.18.8.5 | not-accessible | Information about control circuit parameters. | |
| phivControlParametersEntry | 1.3.6.1.2.1.18.8.5.1 | not-accessible | Parameters information about control circuits currently known. | |
| INT phivControlCircuitIndex | 1.3.6.1.2.1.18.8.5.1.1 | INTEGER | read-only | A unique index value for each known multirpoint control circuit. This is the same value as phivCircuitIndex. |
| INT phivControlBabbleTimer | 1.3.6.1.2.1.18.8.5.1.2 | INTEGER | read-write | This value represents the number of milliseconds that a selected tributary or remote half-duplex station is allowed to transmit. |
| INT phivControlMaxBuffs | 1.3.6.1.2.1.18.8.5.1.3 | INTEGER | read-write | This value represents the maximum number of buffers the tributary can use from a common buffer pool. If not set, there is no common buffer pool and buffers are explicitly supplied by the higher level. Count is a decimal integer in the range 1-254. |
| INT phivControlMaxTransmits | 1.3.6.1.2.1.18.8.5.1.4 | INTEGER | read-write | This value represents the maximum number of data messages that can be transmitted at one time. Count is a decimal integer in the range 1-255. |
| INT phivControlDyingBase | 1.3.6.1.2.1.18.8.5.1.5 | INTEGER | read-write | This value represents the base priority to which a tributary is reset each time it has been polled. A separate base can be set for each of the indicated polling states. Base is a decimal integer in the range 0-255. If not set, the defaults are: active, 255; inactive, 0; and dying, 0. |
| INT phivControlDyingIncrement | 1.3.6.1.2.1.18.8.5.1.6 | INTEGER | read-write | This value represents the increment added to the tributary priority each time the scheduling timer expires. If not set, the defaults are: active, 0; inactive, 64; and dying, 16. |
| INT phivControlDeadThreshold | 1.3.6.1.2.1.18.8.5.1.7 | INTEGER | read-write | This value represents the number of times to poll the active, inactive, or dying tributary before changing its polling state to dead because of receive timeouts. Count is a decimal integer in the range 0-255. |
| INT phivControlDyingThreshold | 1.3.6.1.2.1.18.8.5.1.8 | INTEGER | read-write | This value represents the number of times to poll the active or inactive tributary before changing its polling state to dying because of receive timeouts. Count is a decimal integer in the range 0-255. |
| INT phivControlInactTreshold | 1.3.6.1.2.1.18.8.5.1.9 | INTEGER | read-write | This value represents the number of times to poll the active tributary before changing its polling state to inactive because of no data response. Count is a decimal integer in the range 0-255. |
| INT phivControlPollingState | 1.3.6.1.2.1.18.8.5.1.10 | INTEGER | read-write | This value represents the state of the tributary relative to the multipoint polling algorithm. If not set the default is AUTOMATIC. The possible states are: AUTOMATIC The tributary's state is allowed to vary according to the operation of the polling algorithm. ACTIVE/INACTIVE/DYING/DEAD The tributary is locked in the specified state. NOTE: These values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155. |
| INT phivControlPollingSubState | 1.3.6.1.2.1.18.8.5.1.11 | INTEGER | read-only | This value represents the tributary's state as determined by the polling algorithm. This applies only when the polling state is AUTOMATIC and is read-only to Network Management. Polling-substate is one of ACTIVE, INACTIVE, DYING, or DEAD. It is displayed as a tag on the polling state, for example: AUTOMATIC-INACTIVE. |
| INT phivControlTransTimer | 1.3.6.1.2.1.18.8.5.1.12 | INTEGER | read-write | This value represents the number of milliseconds to delay between data message transmits. Milliseconds is a decimal integer in the range 0-65535. |
| ethernet | 1.3.6.1.2.1.18.9 | |||
| phivEthLinkParametersTable | 1.3.6.1.2.1.18.9.1 | not-accessible | Information about ethernet link parameters. | |
| phivEthLinkParametersEntry | 1.3.6.1.2.1.18.9.1.1 | not-accessible | Parameter information about ethernet links currently known. | |
| INT phivEthLinkIndex | 1.3.6.1.2.1.18.9.1.1.1 | INTEGER | read-only | The circuit over which this links information is collected. This is the same as phivCircuitIndex. |
| PHI phivEthDesigRouterNodeAddr | 1.3.6.1.2.1.18.9.1.1.2 | PhivAddr | read-only | This value is the address of the designated router. |
| INT phivEthMaxRouters | 1.3.6.1.2.1.18.9.1.1.3 | INTEGER | read-write | This parameter is the maximum number of routers (other than the executor itself) allowed on the circuit by Routing for circuits that are owned by the executor node. |
| INT phivEthRouterPri | 1.3.6.1.2.1.18.9.1.1.4 | INTEGER | read-write | This parameter is the priority that this router is to have in the selection of designated router for the circuit on circuits that are owned by the executor node. |
| OCT phivEthHardwareAddr | 1.3.6.1.2.1.18.9.1.1.5 | OCTET STRING | read-only | This read-only parameter is the address that is associated with the line device hardware as seen by the DECnet Software. This value is not the same as ifPhysAddress. |
| counters | 1.3.6.1.2.1.18.10 | |||
| phivCountersCountTable | 1.3.6.1.2.1.18.10.1 | not-accessible | Information about ethernet link counters. | |
| phivCountersCountEntry | 1.3.6.1.2.1.18.10.1.1 | not-accessible | Counter information about ethernet links currently known.. | |
| INT phivCountersIndex | 1.3.6.1.2.1.18.10.1.1.1 | INTEGER | read-only | The interface to which these counters apply. This is the same interface as identified by the same value of phivLineIndex. This value is the IfIndex. |
| NUM phivCountersCountBytesRecd | 1.3.6.1.2.1.18.10.1.1.2 | PhivCounter | read-only | Number of bytes received over this link. |
| NUM phivCountersCountBytesSent | 1.3.6.1.2.1.18.10.1.1.3 | PhivCounter | read-only | Number of bytes sent over this link. |
| NUM phivCountersCountDataBlocksRecd | 1.3.6.1.2.1.18.10.1.1.4 | PhivCounter | read-only | Number of data blocks received over this link. |
| NUM phivCountersCountDataBlocksSent | 1.3.6.1.2.1.18.10.1.1.5 | PhivCounter | read-only | Number of data blocks sent over this link. |
| NUM phivCountersCountEthUsrBuffUnav | 1.3.6.1.2.1.18.10.1.1.6 | PhivCounter | read-only | Number of user buffer unavailable errors over this link. |
| NUM phivCountersCountMcastBytesRecd | 1.3.6.1.2.1.18.10.1.1.7 | PhivCounter | read-only | Number of multicast bytes received over this link. |
| NUM phivCountersCountDataBlksRecd | 1.3.6.1.2.1.18.10.1.1.8 | PhivCounter | read-only | Number of data blocks received over this link. |
| NUM phivCountersCountDataBlksSent | 1.3.6.1.2.1.18.10.1.1.9 | PhivCounter | read-only | Number of data blocks sent over this link. |
| NUM phivCountersCountMcastBlksRecd | 1.3.6.1.2.1.18.10.1.1.10 | PhivCounter | read-only | Number of multicast blocks received over this link. |
| NUM phivCountersCountBlksSentDef | 1.3.6.1.2.1.18.10.1.1.11 | PhivCounter | read-only | Number of blocks sent, initially deferred over this link. |
| NUM phivCountersCountBlksSentSingleCol | 1.3.6.1.2.1.18.10.1.1.12 | PhivCounter | read-only | Number of blocks sent, single collision over this link. |
| NUM phivCountersCountBlksSentMultCol | 1.3.6.1.2.1.18.10.1.1.13 | PhivCounter | read-only | Number of blocks sent, multiple collisions over this link. |
| NUM phivCountersCountSendFailure | 1.3.6.1.2.1.18.10.1.1.14 | PhivCounter | read-only | Number of send failures over this link. |
| NUM phivCountersCountCollDetectFailure | 1.3.6.1.2.1.18.10.1.1.15 | PhivCounter | read-only | Number of collision detect check failures over this link. |
| NUM phivCountersCountReceiveFailure | 1.3.6.1.2.1.18.10.1.1.16 | PhivCounter | read-only | Number of receive failures over this link. |
| NUM phivCountersCountUnrecFrameDest | 1.3.6.1.2.1.18.10.1.1.17 | PhivCounter | read-only | Number of unrecognized frame destinations over this link. |
| NUM phivCountersCountDataOver | 1.3.6.1.2.1.18.10.1.1.18 | PhivCounter | read-only | Number of data overruns over this link. |
| NUM phivCountersCountSysBuffUnav | 1.3.6.1.2.1.18.10.1.1.19 | PhivCounter | read-only | Number of system buffer unavailables over this link. |
| NUM phivCountersCountUsrBuffUnav | 1.3.6.1.2.1.18.10.1.1.20 | PhivCounter | read-only | Number of user buffer unavailables. |
| adjacency | 1.3.6.1.2.1.18.11 | |||
| phivAdjTable | 1.3.6.1.2.1.18.11.1 | not-accessible | The Adjacency Table. | |
| phivAdjEntry | 1.3.6.1.2.1.18.11.1.1 | not-accessible | There is one entry in the table for each adjacency. | |
| INT phivAdjCircuitIndex | 1.3.6.1.2.1.18.11.1.1.1 | INTEGER | read-only | A unique index value for each known circuit. |
| PHI phivAdjNodeAddr | 1.3.6.1.2.1.18.11.1.1.2 | PhivAddr | read-only | The address of the adjacent node. |
| INT phivAdjBlockSize | 1.3.6.1.2.1.18.11.1.1.3 | INTEGER | read-only | This read-only parameter is the block size that was negotiated with the adjacent Routing layer during Routing initialization over a particular circuit. It includes the routing header, but excludes the data link header. This parameter is qualified by ADJACENT NODE. |
| INT phivAdjListenTimer | 1.3.6.1.2.1.18.11.1.1.4 | INTEGER | read-only | This value determines the maximum number of seconds allowed to elapse before Routing receives some message (either a Hello message or a user message) from the adjacent node on the circuit. It was agreed during Routing initialization with the adjacent Routing layer. This parameter is qualified by ADJACENT NODE. |
| OCT phivAdjCircuitEtherServPhysAddr | 1.3.6.1.2.1.18.11.1.1.5 | OCTET STRING | read-only | This parameter indicates the Ethernet physical address of an adjacent node that is being serviced on this circuit. This parameter is a qualifier for SERVICE SUBSTATE. |
| INT phivAdjType | 1.3.6.1.2.1.18.11.1.1.6 | INTEGER | read-only | This parameter indicates the type of adjacency. For adjacent nodes, this is a read-only parameter that indicates the type of the reachable adjacent node. NOTE: The routing-III and nonrouting-III values are incremented by one compared to the standard DECnet values in order to maintain compliance with RFC 1155) |
| INT phivAdjState | 1.3.6.1.2.1.18.11.1.1.7 | INTEGER | read-only | This value indicates the state of a router adjacency. On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjType) ROUTING IV or AREA, this variable is the state of the Ethernet Initialization Layer for this adjacency, and can have values INITIALIZING or UP. (See Section 9.1.1 of DECnet Phase IV Routing Layer Functional Specification.) On adjacencies over a circuit of type (phivCircuitCommonType) Ethernet, CI, or FDDI, with an adjacent node of type (phivAdjType) NONROUTING IV, this variable will always take on the value UP. On adjacencies over a circuit of type (phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL, DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is the state of the Routing Layer Initialization Circuit State. (See section 7.3, ibid.) It can have values between RUN and HALT. On adjacencies over a circuit of type (phivCircuitCommonType) OTHER, this variable may be used in a manner consistent with the Initialization Layer used on that circuit. |
| INT phivAdjPriority | 1.3.6.1.2.1.18.11.1.1.8 | INTEGER | read-only | Priority assigned by the adjacent node for this circuit. |
| INT phivAdjExecListenTimer | 1.3.6.1.2.1.18.11.1.1.9 | INTEGER | read-only | This read-only value determines the maximum number of seconds allowed to elapse before Routing receives some message (either a Hello message or a user message) from the adjacent node on the circuit. It was agreed during Routing initialization with the adjacent Routing layer. |
| line | 1.3.6.1.2.1.18.12 | |||
| phivLineTable | 1.3.6.1.2.1.18.12.1 | not-accessible | The Line Table. | |
| phivLineEntry | 1.3.6.1.2.1.18.12.1.1 | not-accessible | There is one entry in the table for each line. | |
| INT phivLineIndex | 1.3.6.1.2.1.18.12.1.1.1 | INTEGER | read-only | The line on which this entry's equivalence is effective. This is the same as the IfIndex. |
| STR phivLineName | 1.3.6.1.2.1.18.12.1.1.2 | DisplayString | read-only | The name of the line on this row of the table. |
| INT phivLineState | 1.3.6.1.2.1.18.12.1.1.3 | INTEGER | read-only | This value represents Network Management operational state. NOTE that these values are incremented by one compared to the standard DECnet values. |
| INT phivLineSubstate | 1.3.6.1.2.1.18.12.1.1.4 | INTEGER | read-only | This value represents the line's read-only Network Management substate. NOTE that these values are incremented by one compared to the standard DECnet values. |
| INT phivLineService | 1.3.6.1.2.1.18.12.1.1.5 | INTEGER | read-only | This value represents the line's read-only Network Management service. NOTE that these values are incremented by one compared to the standard DECnet values and OTHER is a new addition. |
| STR phivLineDevice | 1.3.6.1.2.1.18.12.1.1.6 | DisplayString | read-only | This value represents the Physical Link device to be used on the line. |
| INT phivLineReceiveBuffs | 1.3.6.1.2.1.18.12.1.1.7 | INTEGER | read-only | This value represents the number of receive buffers reserved for the line. It is a decimal number in the range 0-65535. 0 is supported for those vendors that do not reserve buffers on a per line basis and use a pool of buffers that can be used by any line. |
| INT phivLineProtocol | 1.3.6.1.2.1.18.12.1.1.8 | INTEGER | read-only | This value represents the protocol used on the line device. Note that these values are incremented by one compared to the standard DECnet values. |
| INT phivLineServiceTimer | 1.3.6.1.2.1.18.12.1.1.9 | INTEGER | read-only | This value represents the amount of time in milliseconds allowed to elapse before a Data Link receive request completes while doing service operations. |
| INT phivLineMaxBlock | 1.3.6.1.2.1.18.12.1.1.10 | INTEGER | read-only | This value represents the Data Link maximum block size on the line. |
| nonBroadcastLine | 1.3.6.1.2.1.18.14 | |||
| phivNonBroadcastTable | 1.3.6.1.2.1.18.14.1 | not-accessible | The Non Broadcast Table. | |
| phivNonBroadcastEntry | 1.3.6.1.2.1.18.14.1.1 | not-accessible | There is one entry in the table for each Non Broadcast line. | |
| INT phivNonBroadcastIndex | 1.3.6.1.2.1.18.14.1.1.1 | INTEGER | read-only | The Non Broadcast line on which this entry's equivalence is effective. This is the same value as the IfIndex. |
| INT phivNonBroadcastController | 1.3.6.1.2.1.18.14.1.1.2 | INTEGER | read-only | This value represents the Physical Link hardware controller mode for the line device. The values for controller-mode are: NORMAL For normal controller operating mode. LOOPBACK For software controllable loopback of the controller. On those devices that can support this mode, it causes all transmitted messages to be looped back from within the controller itself. This is accomplished without any manual intervention other than the setting of this parameter value. OTHER indicates function is not supported Note that these values are incremented by one compared to the standard DECnet values. |
| INT phivNonBroadcastDuplex | 1.3.6.1.2.1.18.14.1.1.3 | INTEGER | read-only | This value represents the Physical Link hardware duplex mode of the line device. The possible modes are: FULL Full-duplex HALF Half-duplex Note that these values are incremented by one compared to the standard DECnet values. |
| INT phivNonBroadcastClock | 1.3.6.1.2.1.18.14.1.1.4 | INTEGER | read-only | This value represents the Physical Link hardware clock mode for the line device. The values for clock-mode are: INTERNAL For software controllable loopback use of the clock. On those devices that can support this mode, it causes the device to supply a clock signal such that a transmitted messages can be looped back from outside the device. This may require manual intervention other than the setting of this parameter value. For example, the operator may have to connect a loopback plug in place of the normal line. EXTERNAL For normal clock operating mode, where the clock signal is supplied externally to the controller. Note that these values are incremented by one compared to the standard DECnet values. |
| INT phivNonBroadcastRetransmitTimer | 1.3.6.1.2.1.18.14.1.1.5 | INTEGER | read-only | This value represents number of milliseconds before the Data Link retransmits a block on the line. On half-duplex lines, this parameter is the select timer. |
| area | 1.3.6.1.2.1.18.15 | |||
| phivAreaTable | 1.3.6.1.2.1.18.15.1 | not-accessible | Table of information kept on all areas known to this unit. | |
| phivAreaEntry | 1.3.6.1.2.1.18.15.1.1 | not-accessible | The area routing information. | |
| INT phivAreaNum | 1.3.6.1.2.1.18.15.1.1.1 | INTEGER | read-only | This value indicates the area number of this entry. |
| INT phivAreaState | 1.3.6.1.2.1.18.15.1.1.2 | INTEGER | read-only | This value indicates the state of the area |
| GAU phivAreaCost | 1.3.6.1.2.1.18.15.1.1.3 | Gauge | read-only | The total cost over the current path to the destination area. Cost is a value associated with using a circuit. Routing routes messages (data) along the path between 2 areas with the smallest cost. |
| INT phivAreaHops | 1.3.6.1.2.1.18.15.1.1.4 | INTEGER | read-only | The number of hops to a destination area. A hop is the routing value representing the logical distance between two areas in network. |
| PHI phivAreaNextNode | 1.3.6.1.2.1.18.15.1.1.5 | PhivAddr | read-only | The next node on the circuit used to get to the area under scrutiny. |
| INT phivAreaCircuitIndex | 1.3.6.1.2.1.18.15.1.1.6 | INTEGER | read-only | A unique index value for each known circuit. |
| INT phivAreaMaxCost | 1.3.6.1.2.1.18.15.2 | INTEGER | read-write | This value represents the maximum total path cost allowed from the executor to any other level 2 routing node. The AREA MAXIMUM COST number is decimal in the range 1-1022. This parameter is only applicable if the executor node is of type AREA. |
| INT phivAreaMaxHops | 1.3.6.1.2.1.18.15.3 | INTEGER | read-write | This value represents the maximum number of routing hops allowable from the executor to any other level 2 routing node. This parameter is only applicable if the executor node is of type AREA. |
| INT phivRouteMaxArea | 1.3.6.1.2.1.18.15.4 | INTEGER | read-write | This value represents the largest area number and, therefore, number of areas that can be known about by the executor node's Routing. This parameter is only applicable if the executor node is of type AREA. |
RFC description
Manages DECnet Phase IV networks including routing, circuits, and node adjacencies.
Start monitoring DECnet Phase IV network nodes with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.