CPS6000-MIB :: cps6000Dc1Vdc

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPS6000-MIBcps6000Dc1Vdc

cps6000Dc1Vdc

Module: CPS6000-MIB

OID (symbolic): CPS6000-MIB::cps6000Dc1Vdc

OID (numeric): 1.3.6.1.4.1.10520.2.1.1.1.5

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Voltage (mV)

What is cps6000Dc1Vdc?

This read-only Integer32 reports the DC bus voltage of the Dc1 plant, measured in millivolts. It's the core live voltage reading an admin monitors to confirm the DC plant is delivering power within its expected operating range. For example, a reading of 54200 corresponds to a bus voltage of 54.2 volts, typical for a telecom -48V DC plant.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10520.2.1.1.1.5
snmpwalk -v2c -c public <target> CPS6000-MIB::cps6000Dc1Vdc

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10520.2.1.1.1.5.1
snmpget -v2c -c public <target> CPS6000-MIB::cps6000Dc1Vdc.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cps6000Dc1Vdc.1

Start monitoring CyberPower CPS6000-series UPS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPS6000-MIB::cps6000Dc1Vdc OID value, configure state conditions and alerts, and monitor any CyberPower CPS6000-series UPS from a single console.

How to Use in IPNetwork Monitor

Select a CyberPower CPS6000-series UPS as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cps6000Dc1Vdc into the Find box to locate it in the OID tree, then select it and click OK. It reports the voltage (mV). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reading drifts outside the range expected for healthy operation (in mV), since an unexpected voltage swing often points to a power-supply or wiring issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10520tepsCPS6000-MIB
1.3.6.1.4.1.10520.2controllermibsCPS6000-MIB
1.3.6.1.4.1.10520.2.1releaseCPS6000-MIB
1.3.6.1.4.1.10520.2.1.1cps6000CPS6000-MIB
1.3.6.1.4.1.10520.2.1.1.1cps6000Dc1CPS6000-MIB
1.3.6.1.4.1.10520.2.1.1.1.5cps6000Dc1VdcCPS6000-MIB