All MIBs › CPQSTSYS-MIB › cpqSsPowerSupplyBay
cpqSsPowerSupplyBay
Module: CPQSTSYS-MIB
OID (symbolic): CPQSTSYS-MIB::cpqSsPowerSupplyBay
OID (numeric): 1.3.6.1.4.1.232.8.2.2.3.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Storage System Power Supply Bay.
The following values are defined:
other(1) The agent does not recognize the bay. You may need to upgrade your software.
powerBay1(2) The power supply is installed in the first power supply bay.
powerBay2(3) The power supply is installed in the second power supply bay.
composite(4) The power supply information is a composite of all power supplies in the storage system.
What is cpqSsPowerSupplyBay?
This read-only enumerated value indicates which physical bay a power supply occupies: the first bay, the second bay, or a composite reading covering all supplies. Administrators use it to know exactly which power supply slot a status reading applies to. For example, powerBay2(3) tells the admin the reading corresponds to the second power supply bay specifically.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.3.1.3 snmpwalk -v2c -c public <target> CPQSTSYS-MIB::cpqSsPowerSupplyBay
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.3.1.3.1 snmpget -v2c -c public <target> CPQSTSYS-MIB::cpqSsPowerSupplyBay.1
Start monitoring HP/Compaq StorageWorks storage array (RAID/logical volume/disk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSTSYS-MIB::cpqSsPowerSupplyBay OID value, configure state conditions and alerts, and monitor any HP/Compaq StorageWorks storage array (RAID/logical volume/disk) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.8 | cpqSsStorageSys | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2 | cpqSsDrvBox | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2 | cpqSsBoxExtended | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.3 | cpqSsPowerSupplyTable | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.3.1 | cpqSsPowerSupplyEntry | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.3.1.3 | cpqSsPowerSupplyBay | CPQSTSYS-MIB |