CPQSTSYS-MIB :: cpqSsChassisModel

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCPQSTSYS-MIBcpqSsChassisModel

cpqSsChassisModel

Module: CPQSTSYS-MIB

OID (symbolic): CPQSTSYS-MIB::cpqSsChassisModel

OID (numeric): 1.3.6.1.4.1.232.8.2.2.1.1.19

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Storage System Chassis Model.

The following values are defined:

other(1) The agent is unable to determine the model of this chassis.

ra4x00(2) Compaq StorageWorks RAID Array 4000/4100.

msa1000(3) Compaq StorageWorks Modular Smart Array 1000.

smartArrayClusterStorage(4) HP StorageWorks Modular Smart Array 500 (Formerly Smart Array Cluster Storage).

enterpriseModularArray(5) Compaq StorageWorks Enterprise/Modular RAID Array.

enterpriseVirtualArray(6) Compaq StorageWorks Enterprise Virtual Array.

msa500G2(7) HP StorageWorks Modular Smart Array 500 G2.

msa20(8) HP StorageWorks Modular Smart Array 20.

msa1500cs(9) HP StorageWorks Modular Smart Array 1500 CS.

msa1510i(10) HP StorageWorks Modular Smart Array 1510i.

Reserved(11)

Reserved(12)

What is cpqSsChassisModel?

This read-only enumerated value identifies the specific storage chassis model, such as an RA4000/4100 RAID array, an MSA1000, or an Enterprise Virtual Array. Administrators use it to know exactly what enclosure hardware they're managing without physically checking labels. For example, a value of msa1000(3) confirms the chassis is a Compaq StorageWorks Modular Smart Array 1000 rather than a different model.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.1.1.19
snmpwalk -v2c -c public <target> CPQSTSYS-MIB::cpqSsChassisModel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.1.1.19.1
snmpget -v2c -c public <target> CPQSTSYS-MIB::cpqSsChassisModel.1

Start monitoring HP/Compaq StorageWorks storage array (RAID/logical volume/disk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSTSYS-MIB::cpqSsChassisModel OID value, configure state conditions and alerts, and monitor any HP/Compaq StorageWorks storage array (RAID/logical volume/disk) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.8cpqSsStorageSysCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2cpqSsDrvBoxCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2.2cpqSsBoxExtendedCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2.2.1cpqSsChassisTableCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2.2.1.1cpqSsChassisEntryCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2.2.1.1.19cpqSsChassisModelCPQSTSYS-MIB