All MIBs › CPQSTSYS-MIB › cpqSsScsiAttachmentPathStatus
cpqSsScsiAttachmentPathStatus
Module: CPQSTSYS-MIB
OID (symbolic): CPQSTSYS-MIB::cpqSsScsiAttachmentPathStatus
OID (numeric): 1.3.6.1.4.1.232.8.2.2.8.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Storage System SCSI Attachment Path Status.
This is the status of this path to the chassis. The following values are defined:
other(1) The agent does not recognize the status. You may need to upgrade your software.
ok(2) The path is operating normally.
offline(3) The path is offline.
What is cpqSsScsiAttachmentPathStatus?
This read-only enumerated value reports whether a SCSI attachment path to a chassis is operating normally or offline. Administrators monitor this to detect a broken cable or connection path even if the storage box itself is otherwise healthy. For example, offline(3) would alert the admin that this specific path has gone down and needs cable or connector inspection.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.8.1.8 snmpwalk -v2c -c public <target> CPQSTSYS-MIB::cpqSsScsiAttachmentPathStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.8.1.8.1 snmpget -v2c -c public <target> CPQSTSYS-MIB::cpqSsScsiAttachmentPathStatus.1
Start monitoring HP/Compaq StorageWorks storage array (RAID/logical volume/disk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSTSYS-MIB::cpqSsScsiAttachmentPathStatus OID value, configure state conditions and alerts, and monitor any HP/Compaq StorageWorks storage array (RAID/logical volume/disk) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.8 | cpqSsStorageSys | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2 | cpqSsDrvBox | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2 | cpqSsBoxExtended | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.8 | cpqSsScsiAttachmentTable | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.8.1 | cpqSsScsiAttachmentEntry | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.8.1.8 | cpqSsScsiAttachmentPathStatus | CPQSTSYS-MIB |