Description: Storage System Fan Module Location.
The following values are defined:
other(1) The agent is unable to determine the location of this storage system fan module.
fanBay(2) This fan module is installed in the first fan bay.
composite(3) The fan information is a composite of all fans in the storage system.
fanBay2(4) This fan module is installed in the second fan bay.
What is cpqSsFanModuleLocation?
This read-only enumerated value reports where a fan module is physically located, such as the first fan bay, a composite of all fans, or the second fan bay. Administrators use it to know exactly which bay to check when a specific fan module reports a problem. For example, fanBay2(4) tells a technician to check the second fan bay rather than the first.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.4.1.5 snmpwalk -v2c -c public <target> CPQSTSYS-MIB::cpqSsFanModuleLocation
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.8.2.2.4.1.5.1 snmpget -v2c -c public <target> CPQSTSYS-MIB::cpqSsFanModuleLocation.1
Start monitoring HP/Compaq StorageWorks storage array (RAID/logical volume/disk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQSTSYS-MIB::cpqSsFanModuleLocation OID value, configure state conditions and alerts, and monitor any HP/Compaq StorageWorks storage array (RAID/logical volume/disk) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.8 | cpqSsStorageSys | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2 | cpqSsDrvBox | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2 | cpqSsBoxExtended | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.4 | cpqSsFanModuleTable | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.4.1 | cpqSsFanModuleEntry | CPQSTSYS-MIB |
| 1.3.6.1.4.1.232.8.2.2.4.1.5 | cpqSsFanModuleLocation | CPQSTSYS-MIB |