CPQSTSYS-MIB :: cpqSsBoxFanStatus

MIB Reference — IPNetwork Monitor

All MIBsCPQSTSYS-MIBcpqSsBoxFanStatus

cpqSsBoxFanStatus

Module: CPQSTSYS-MIB

OID (symbolic): CPQSTSYS-MIB::cpqSsBoxFanStatus

OID (numeric): 1.3.6.1.4.1.232.8.2.1.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description:

Drive Box Fan Status.

This is the current status of the fans in the drive box. This value will be one of the following: other(1) Fan monitoring is not supported by this system or it is not supported by the driver.

ok(2) All fans are working normally.

failed(3) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage.

noFan(4) This unit does not support fan monitoring.

degraded(5) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.8.2.1.1.7
snmpwalk -v2c -c public <target> CPQSTSYS-MIB::cpqSsBoxFanStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.232.8.2.1.1.7.1
snmpget -v2c -c public <target> CPQSTSYS-MIB::cpqSsBoxFanStatus.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
1.3.6.1.4.1.232.8cpqSsStorageSysCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2cpqSsDrvBoxCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2.1cpqSsDrvBoxTableCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2.1.1cpqSsDrvBoxEntryCPQSTSYS-MIB
1.3.6.1.4.1.232.8.2.1.1.7cpqSsBoxFanStatusCPQSTSYS-MIB