ADC-FLEXWAVE-URH-MIB

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsADC-FLEXWAVE-URH-MIB

Organization: TE Connectivity

Last Updated: 2012-10-03

Category: Optical and WDM

Description: Manages ADC FlexWave Ultra Remote Head (URH) distributed antenna and remote radio unit configuration and status.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ADC-FLEXWAVE-URH-MIB?

ADC-FLEXWAVE-URH-MIB is a distributed antenna system (DAS) vendor MIB from ADC (now part of CommScope) for the FlexWave Prism and InterReach SPECTRUM Ultra Remote Head (URH) product line, remote radio head units used to extend cellular coverage. It exposes fault/alarm and trap data describing module identity and trap events, plus host unit (Hst) hardware objects such as unit reset control and backplane revision. Its principal use is fault and hardware-status monitoring: tracking alarmed module names/types, trap codes and sequence numbers to identify which remote radio module raised an alarm, and host unit hardware attributes to verify hardware health and recover a hung unit via remote reset. No explicit dependency on standard IETF MIBs is indicated in the available definitions, though it likely complements the vendor's broader FlexWave MIB suite. It is deployed in distributed antenna system installations (e.g., stadiums, campuses, buildings) where FlexWave URH remote radio heads relay cellular signal and must be centrally monitored for alarms and hardware faults, and administrators can get an ADC-FLEXWAVE-URH-MIB download to load its trap and hardware objects directly into a MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in ADC-FLEXWAVE-URH-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • ADC FlexWave Ultra Remote Head (URH) distributed antenna system remote radio unit

Monitoring Examples

An operator watching fwuTrapCode, fwuAlarmedModuleName, and fwuModuleType together with fwuTrapNodeAddress can pinpoint which remote head module raised an alarm and where it sits in the distributed antenna network. fwuTrapSequenceNumber and fwuTrapTimeStamp let them correlate the order and timing of alarms during a fault storm. If a host unit becomes unresponsive, fwuHstUnitReset can be used to remotely reset it, while fwuHstBackPlaneRev confirms hardware revision compatibility during troubleshooting.

What Can Be Monitored

  • alarm/trap codes and sequence
  • alarmed module identity and type
  • trap source node address
  • host unit backplane revision
  • host unit reset control/status
Imported Objects

From ADC-FWU-URH-TC-MIB

ALARMEnable
ALARMManage
ALARMType
BANDType
CATALOGType
CONTACTType
DELAYType
DuplexerType
ENETType
GAINType
LNAType
MODEType
MODULEType
OPTICSType
RauBandType
UnitID2
UnitID3
UnitType

From SNMPv2-CONF

MODULE-COMPLIANCE
NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

Counter32
Counter64
Integer32
IpAddress
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-IDENTITY
OBJECT-TYPE
TimeTicks
Unsigned32
enterprises

From SNMPv2-TC

DateAndTime
DisplayString
RowStatus
TEXTUAL-CONVENTION

How to Use in IPNetwork Monitor

Example using fwuHstSERFEthPortRxBytes OID:

Select an ADC/TE FlexWave DAS remote radio unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type fwuHstSERFEthPortRxBytes into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the count of the number of recieved bytes at this ethernet port. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Manages TE Connectivity FlexWave Prism and InterReach SPECTRUM radio frequency products for version 8.1 and later.

Start monitoring ADC/TE FlexWave DAS remote radio units with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ADC-FLEXWAVE-URH-MIB