All MIBs › ADC-FLEXWAVE-URH-MIB › fwuRmtPwrDetectorNoRfPowerThershold
fwuRmtPwrDetectorNoRfPowerThershold
Module: ADC-FLEXWAVE-URH-MIB
OID (symbolic): ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorNoRfPowerThershold
OID (numeric): 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.8
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: Threshold value for RF No Power. The minimum threshold value is 0dBm and maximum threshold value is 100dBm.
What is fwuRmtPwrDetectorNoRfPowerThershold?
This read-write threshold value (0–100 dBm) defines the power level below which the system will trigger an 'RF No Power' alarm. An engineer configures this based on the site's minimum required transmit power—too high and you get false alarms, too low and you miss real outages. For example, if the normal output is 36 dBm, you might set the threshold to 15 dBm so that any drop below that indicates a serious problem requiring investigation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.8 snmpwalk -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorNoRfPowerThershold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.8.1 snmpget -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorNoRfPowerThershold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.8.1 s <value>
Start monitoring ADC/TE FlexWave DAS remote radio units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorNoRfPowerThershold OID value, configure state conditions and alerts, and monitor any ADC/TE FlexWave DAS remote radio units from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2014 | adc | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15 | flexwave | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2 | flexwaveurh | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1 | flexwaveURHMibModule | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2 | fwuRemoteUnitObjects | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.9 | fwuRmtPwrDetectorBoardObjects | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.9.1 | fwuRmtPwrDetectorBoardInfo | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.9.1.1 | fwuRmtPwrDetectorBoardInfoTable | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1 | fwuRmtPwrDetectorBoardInfoEntry | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.8 | fwuRmtPwrDetectorNoRfPowerThershold | ADC-FLEXWAVE-URH-MIB |