All MIBs › ADC-FLEXWAVE-URH-MIB › fwuRmtSERFOptFwdLaunchPowerMeas
fwuRmtSERFOptFwdLaunchPowerMeas
Module: ADC-FLEXWAVE-URH-MIB
OID (symbolic): ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptFwdLaunchPowerMeas
OID (numeric): 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.6
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: Value of the optical power, in dBm transmitted by the remote.
What is fwuRmtSERFOptFwdLaunchPowerMeas?
This OID stores the optical power level (measured in dBm) that the remote unit is transmitting toward the far end. Network engineers monitor this value to verify the remote is operating at the correct optical signal strength and to troubleshoot link quality issues. A typical value might be -3.5 dBm, which means the remote is launching light at that power level.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.6 snmpwalk -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptFwdLaunchPowerMeas
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.6.1 snmpget -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptFwdLaunchPowerMeas.1
Start monitoring ADC/TE FlexWave DAS remote radio units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptFwdLaunchPowerMeas OID value, configure state conditions and alerts, and monitor any ADC/TE FlexWave DAS remote radio units from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2014 | adc | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15 | flexwave | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2 | flexwaveurh | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1 | flexwaveURHMibModule | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2 | fwuRemoteUnitObjects | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.2 | fwuRmtSERFObjects | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.2.1 | fwuRmtSERFInfo | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.2.1.2 | fwuRmtSERFOptObjects | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1 | fwuRmtSERFOptTable | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1 | fwuRmtSERFOptEntry | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.6 | fwuRmtSERFOptFwdLaunchPowerMeas | ADC-FLEXWAVE-URH-MIB |