ADC-FLEXWAVE-URH-MIB :: fwuRmtPwrDetectorBoardRIHWVer

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADC-FLEXWAVE-URH-MIBfwuRmtPwrDetectorBoardRIHWVer

fwuRmtPwrDetectorBoardRIHWVer

Module: ADC-FLEXWAVE-URH-MIB

OID (symbolic): ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorBoardRIHWVer

OID (numeric): 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.7

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: Power Detector Inventory - HW version.

What is fwuRmtPwrDetectorBoardRIHWVer?

This read-only field records the hardware version or revision level of the power detector board, such as 'v2.1' or 'Rev B'. Engineers use hardware versions to determine firmware compatibility, feature availability, and whether known bugs or limitations apply to the installed board. For example, discovering that all failing sites have 'Rev A' hardware might reveal a design flaw specific to that revision.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.7
snmpwalk -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorBoardRIHWVer

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.7.1
snmpget -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorBoardRIHWVer.1

Start monitoring ADC/TE FlexWave DAS remote radio units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADC-FLEXWAVE-URH-MIB::fwuRmtPwrDetectorBoardRIHWVer OID value, configure state conditions and alerts, and monitor any ADC/TE FlexWave DAS remote radio units from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2014adcADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15flexwaveADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2flexwaveurhADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1flexwaveURHMibModuleADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2fwuRemoteUnitObjectsADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.9fwuRmtPwrDetectorBoardObjectsADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.9.1fwuRmtPwrDetectorBoardInfoADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.9.1.1fwuRmtPwrDetectorBoardInfoTableADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1fwuRmtPwrDetectorBoardInfoEntryADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.9.1.1.1.7fwuRmtPwrDetectorBoardRIHWVerADC-FLEXWAVE-URH-MIB