All MIBs › ADC-FLEXWAVE-URH-MIB › fwuRmtDARTReverseGainMode
fwuRmtDARTReverseGainMode
Module: ADC-FLEXWAVE-URH-MIB
OID (symbolic): ADC-FLEXWAVE-URH-MIB::fwuRmtDARTReverseGainMode
OID (numeric): 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.34
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The gain modes on the Reverse Path. Two modes are supported, Normal(0) and High(1). It is applicable to all RF modules but not to IF DARTs.
What is fwuRmtDARTReverseGainMode?
This OID toggles the amplification level of the reverse (return) signal path between normal and high gain settings. Engineers switch to high gain when the return signal is too weak to reach the upstream receiver reliably. Example: Setting this to high(1) increases reverse-path amplification to compensate for excessive cable loss or weak transmitter output.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.34 snmpwalk -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtDARTReverseGainMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.34.1 snmpget -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtDARTReverseGainMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.34.1 i <value>
Start monitoring ADC/TE FlexWave DAS remote radio units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADC-FLEXWAVE-URH-MIB::fwuRmtDARTReverseGainMode OID value, configure state conditions and alerts, and monitor any ADC/TE FlexWave DAS remote radio units from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2014 | adc | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15 | flexwave | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2 | flexwaveurh | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1 | flexwaveURHMibModule | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2 | fwuRemoteUnitObjects | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.6 | fwuRmtDARTObjects | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.6.1 | fwuRmtDARTInfo | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.6.1.1 | fwuRmtDARTGeneral | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1 | fwuRmtDARTGeneralTable | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1 | fwuRmtDARTGeneralEntry | ADC-FLEXWAVE-URH-MIB |
| 1.3.6.1.4.1.2014.15.2.1.2.6.1.1.1.1.34 | fwuRmtDARTReverseGainMode | ADC-FLEXWAVE-URH-MIB |