Module: ADC-FLEXWAVE-URH-MIB

OID (symbolic): ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptRevLaunchPowerMeas

OID (numeric): 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.5

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: Value of the optical power, in dBm received at the remote.

What is fwuRmtSERFOptRevLaunchPowerMeas?

This OID contains the received optical power level at the remote end of the fiber link, measured in dBm and stored as text. Engineers monitor this value to detect fiber degradation, dirty connectors, or failing transceivers; weak power indicates the link is at risk. For example, "-15.5" means the signal strength is 15.5 dBm below 1 milliwatt, which is a typical healthy receive level for this type of system.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.5
snmpwalk -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptRevLaunchPowerMeas

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.5.1
snmpget -v2c -c public <target> ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptRevLaunchPowerMeas.1

Start monitoring ADC/TE FlexWave DAS remote radio units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADC-FLEXWAVE-URH-MIB::fwuRmtSERFOptRevLaunchPowerMeas OID value, configure state conditions and alerts, and monitor any ADC/TE FlexWave DAS remote radio units from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2014adcADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15flexwaveADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2flexwaveurhADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1flexwaveURHMibModuleADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2fwuRemoteUnitObjectsADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.2fwuRmtSERFObjectsADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.2.1fwuRmtSERFInfoADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.2.1.2fwuRmtSERFOptObjectsADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1fwuRmtSERFOptTableADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1fwuRmtSERFOptEntryADC-FLEXWAVE-URH-MIB
1.3.6.1.4.1.2014.15.2.1.2.2.1.2.1.1.5fwuRmtSERFOptRevLaunchPowerMeasADC-FLEXWAVE-URH-MIB