All MIBs › OMNI-gx2LME-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 LME enhanced laser module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2LME-MIB?
OMNI-gx2LME-MIB is a Cisco (originating from Scientific-Atlanta's OMNI product line) MIB for the GX2 Laser Module Enhanced (LME), an optical transmitter module used in hybrid fiber-coax (HFC) cable-plant optical nodes to convert electrical RF signals to laser light for fiber transport. Based on its stated purpose it would expose configuration and status data for the laser transmitter, such as optical output power, laser bias current, operating temperature, and alarm/fault status, though no specific object names were available from the source to confirm exact identifiers. Its monitoring emphasis, consistent with laser/optical transmitter MIBs generally, would be on hardware health: optical output level, laser temperature, and fault/alarm conditions that indicate impending laser degradation or failure in the HFC plant. No dependency information is available from the provided context, though it likely aligns with other Scientific-Atlanta/Cisco HFC optical-node MIBs. It is typically deployed in Cisco/Scientific-Atlanta HFC optical nodes used by cable operators to deliver signal over fiber-to-coax network segments, and cable engineers generally need an OMNI-gx2LME-MIB download from Cisco/Scientific-Atlanta to compile these laser-module objects for their optical node NMS.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2LME-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 LME laser module enhanced transmitter)
Monitoring Examples
No object or table names were provided in the source for this module, so a concrete polling scenario cannot be grounded in real identifiers. In practice, a cable operator's NMS would be expected to monitor laser optical output power, bias current, and temperature/alarm status to catch a degrading laser module before it causes signal-quality issues on the downstream HFC plant, but specific object names are unknown from the available data.
What Can Be Monitored
- laser optical output power
- laser bias current
- module temperature
- laser fault/alarm status
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2LmE | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapLMEConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.27.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapLMEConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.27.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapLMERFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.3 | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMERFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.4 | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMERFOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.5 | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMEOpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.6 | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMELaserBiasAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.7 | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMELaserTempAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.8 | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMETECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.9 | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMEFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.10 | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLME12vAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.11 | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMEModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.12 | This trap is issued when the Laser Module Temperature goes out of range. | ||
| NTF trapLMEFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.13 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapLMELaserBiasCntLoopAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.14 | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| NTF trapLMEBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.15 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapLMELaserBiasCntLoopInitAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.16 | This trap is issued when the Laser Bias Control loop init fails. | ||
| NTF trapLMERFParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.17 | This trap is issued when the RF parameter Init fails. | ||
| NTF trapLMETECParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.18 | This trap is issued when the TEC Parameter Init fails. | ||
| NTF trapLMEAttnTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.19 | This trap is issued when the Attenuator Table Init fails. | ||
| NTF trapLMEPowerMeterTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.20 | This trap is issued when the Power Meter Table Init fails. | ||
| NTF trapLMELaserDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.21 | This trap is issued when the Laser Data CRC is incorrect. | ||
| NTF trapLMEAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.22 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapLMEFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.23 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapLMEUserRFOffAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.24 | This trap is issued when the the User RF is turned off. | ||
| NTF trapLMEUserOpticalOffAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.25 | This trap is issued when the User Optical Power is turned off. | ||
| NTF trapLMEResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.27.0.26 | This trap is issued when the Factory Default Reset occurs. | ||
| gx2lmeDescriptor | 1.3.6.1.4.1.1166.6.1.2.27.1 | |||
| gx2lmeAnalogTable | 1.3.6.1.4.1.1166.6.1.2.27.2 | not-accessible | This table contains gx2LmE specific parameters with nominal and current values. | |
| gx2lmeAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.27.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2lmeAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.27.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lmelabelOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Offset Monitor Analog parameter. |
| STR lmeuomOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| FLO lmemajorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO lmeminorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.8 | Float | read-only | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| INT lmestateFlagOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO lmeminValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.10 | Float | read-only | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| FLO lmemaxValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.11 | Float | read-only | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| INT lmealarmStateOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.27.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| STR lmelabelOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| STR lmeuomOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.14 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| FLO lmemajorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO lmemajorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO lmeminorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.19 | Float | read-write | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO lmeminValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.21 | Float | read-only | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.22 | Float | read-only | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| STR lmelabelRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Attenuator Setting Analog parameter. |
| STR lmeuomRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. |
| FLO lmemajorHighRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.30 | Float | read-write | The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.32 | Float | read-only | The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.33 | Float | read-only | The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.27.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter. |
| STR lmelabelOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR lmeuomOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO lmemajorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.41 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValueOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.43 | Float | read-only | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.44 | Float | read-only | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.27.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR lmelabelLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR lmeuomLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| FLO lmemajorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.52 | Float | read-only | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.54 | Float | read-only | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.55 | Float | read-only | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.27.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| STR lmelabelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.57 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR lmeuomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| FLO lmemajorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.63 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.64 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.65 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.66 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR lmelabelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Laser Temperature Analog parameter. |
| STR lmeuomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| FLO lmemajorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.74 | Float | read-only | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.76 | Float | read-only | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.77 | Float | read-only | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| STR lmelabelModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR lmeuomModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO lmemajorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.85 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.87 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.88 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateModuleTemp | 1.3.6.1.4.1.1166.6.1.2.27.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR lmelabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR lmeuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO lmemajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.96 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.98 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.99 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.27.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR lmelabel12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.101 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR lmeuom12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO lmemajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmeminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmecurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.107 | Float | read-only | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmestateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.108 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lmeminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.109 | Float | read-only | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lmemaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.110 | Float | read-only | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lmealarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.27.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2lmeDigitalTable | 1.3.6.1.4.1.1166.6.1.2.27.3 | not-accessible | This table contains gx2LmE specific parameters with nominal and current values. | |
| gx2lmeDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.27.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2lmeDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.27.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lmelabelRfInput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR lmeenumRfInput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lmevalueRfInput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lmestateflagRfInput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelOptOutput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Optical Output Control Digital parameter. |
| STR lmeenumOptOutput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lmevalueOptOutput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lmestateflagOptOutput | 1.3.6.1.4.1.1166.6.1.2.27.3.2.9 | INTEGER | read-only | The value of this object provides the lmestate of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelLaserMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Laser Mode Digital parameter. |
| STR lmeenumLaserMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lmevalueLaserMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lmestateflagLaserMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| STR lmeenumLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lmevalueLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lmestateflagLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.27.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelVideoOffset | 1.3.6.1.4.1.1166.6.1.2.27.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Video Offset Digital parameter. |
| STR lmeenumVideoOffset | 1.3.6.1.4.1.1166.6.1.2.27.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.. |
| INT lmevalueVideoOffset | 1.3.6.1.4.1.1166.6.1.2.27.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lmestateflagVideoOffset | 1.3.6.1.4.1.1166.6.1.2.27.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.27.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR lmeenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.27.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lmevalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.27.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lmestateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.27.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelFiberLength | 1.3.6.1.4.1.1166.6.1.2.27.3.2.26 | DisplayString | read-only | This object is only used for the LC1000 device family. The value of this object provides the label for the Fiber Length Digital parameter . |
| STR lmeenumFiberLength | 1.3.6.1.4.1.1166.6.1.2.27.3.2.27 | DisplayString | read-only | This object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 6 to 25km, where 6km is represented with a 1 and 25 with a 19. |
| INT lmevalueFiberLength | 1.3.6.1.4.1.1166.6.1.2.27.3.2.28 | INTEGER | read-write | This object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 0 to 30 Km. |
| INT lmestateflagFiberLength | 1.3.6.1.4.1.1166.6.1.2.27.3.2.29 | INTEGER | read-only | This object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelConditioningUnit | 1.3.6.1.4.1.1166.6.1.2.27.3.2.30 | DisplayString | read-only | This object is only used for the LC1000 device family. The value of this object provides the label for the Conditioning Unit Digital parameter . |
| STR lmeenumConditioningUnit | 1.3.6.1.4.1.1166.6.1.2.27.3.2.31 | DisplayString | read-only | This object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter. |
| INT lmevalueConditioningUnit | 1.3.6.1.4.1.1166.6.1.2.27.3.2.32 | INTEGER | read-write | This object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to normalize the output by -3db when a conditioning unit is being used in the system. |
| INT lmestateflagConditioningUnit | 1.3.6.1.4.1.1166.6.1.2.27.3.2.33 | INTEGER | read-only | This object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2lmeStatusTable | 1.3.6.1.4.1.1166.6.1.2.27.4 | not-accessible | This table contains gx2LmE specific parameters with nominal and current values. | |
| gx2lmeStatusEntry | 1.3.6.1.4.1.1166.6.1.2.27.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2lmeStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.27.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lmelabelBoot | 1.3.6.1.4.1.1166.6.1.2.27.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT lmevalueBoot | 1.3.6.1.4.1.1166.6.1.2.27.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lmestateflagBoot | 1.3.6.1.4.1.1166.6.1.2.27.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelFlash | 1.3.6.1.4.1.1166.6.1.2.27.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT lmevalueFlash | 1.3.6.1.4.1.1166.6.1.2.27.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lmestateflagFlash | 1.3.6.1.4.1.1166.6.1.2.27.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.27.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT lmevalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.27.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lmestateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.27.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.27.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT lmevalueLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.27.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lmestateflagLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.27.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.27.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT lmevalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.27.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lmestateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.27.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelHWStatus | 1.3.6.1.4.1.1166.6.1.2.27.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Laser Drive Level Status parameter. |
| INT lmevalueHWStatus | 1.3.6.1.4.1.1166.6.1.2.27.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lmestateflagHWStatus | 1.3.6.1.4.1.1166.6.1.2.27.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lmelabelRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.27.4.3.20 | DisplayString | read-only | The value of this object provides the label of the RF Input Status parameter. |
| INT lmevalueRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.27.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lmestateflagRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.27.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2lmeFactoryTable | 1.3.6.1.4.1.1166.6.1.2.27.5 | not-accessible | This table contains gx2LmE specific parameters with nominal and current values. | |
| gx2lmeFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.27.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2lmeFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.27.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT lmebootControlByteValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT lmebootStatusByteValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT lmebank1CRCValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT lmebank2CRCValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT lmeprgEEPROMByteValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT lmefactoryCRCValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT lmecalculateCRCValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT lmehourMeterValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT lmeflashPrgCntAValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT lmeflashPrgCntBValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR lmeflashBankARevValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR lmeflashBankBRevValue | 1.3.6.1.4.1.1166.6.1.2.27.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| gx2Lm1000EHoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.27.6 | not-accessible | This table contains gx2Lm1000E specific parameters with nominal and current values. | |
| gx2Lm1000EHoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.27.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Lm1000EHoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.27.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT gx2Lm1000EHoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.27.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT gx2Lm1000EHoldTimeData | 1.3.6.1.4.1.1166.6.1.2.27.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Manages OMNISTAR Laser Module (forward path transmitter) in HFC cable networks.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 LME laser module enhanced transmitter) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.