All MIBs › OMNI-gx2oa100bd-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 OA100BD optical attenuator module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2oa100bd-MIB?
OMNI-gx2oa100bd-MIB is a vendor MIB for the Cisco/Scientific-Atlanta GX2 OA100BD, an optical attenuator module used in HFC optical node deployments to adjust optical signal levels entering downstream receivers. It exposes configuration objects for the attenuation setting along with module status within the GX2 chassis management model. Its main monitoring purpose is hardware health and configuration state of the attenuator, letting operators verify the attenuation level is correctly set and detect a module that has failed or dropped offline, which would otherwise cause optical overload or underdrive downstream. It belongs to the OMNI-gx2 family of modules alongside the laser, amplifier, switch, and receiver MIBs, sharing a common chassis/slot model. It is typically deployed in HFC optical nodes where optical power levels must be trimmed for proper receiver operation. Engineers can download the OMNI-gx2oa100bd-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2oa100bd-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 OA100BD optical attenuator module)
Monitoring Examples
No sample object names were provided for this module; in practice an operator would poll the OA100BD's attenuation-setting and module-status objects within the GX2 chassis tree. An attenuation value drifting from its configured setting, or a module reporting a fault, would reveal a hardware problem causing incorrect optical power delivery to downstream equipment. It is typically monitored alongside other OMNI-gx2 module MIBs for the same optical node chassis.
What Can Be Monitored
- attenuation level setting
- module operational status
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2OA100BD | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapOA100BDConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.17.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapOA100BDConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.17.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapOA100BDModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.3 | This trap is issued when the OA100B Module's Temperature goes out of range. | ||
| NTF trapOA100BDOpticalInPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.4 | This trap is issued when the input Optical Input Power parameter goes out of range. | ||
| NTF trapOA100BDOpticalOutPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.5 | This trap is issued when the input Optical Output Power parameter goes out of range. | ||
| NTF trapOA100BDMainTECTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.6 | This trap is issued when the OA100B Main TEC Temperature goes out of range. | ||
| NTF trapOA100BDMainLaserPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.7 | This trap is issued when the OA100B Main Laser Power goes out of range. | ||
| NTF trapOA100BDAuxTECTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.8 | This trap is issued when the OA100B Aux TEC Temperature goes out of range. | ||
| NTF trapOA100BDAuxLaserPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.9 | This trap is issued when the OA100B Aux Laser Power goes out of range. | ||
| NTF trapOA100BDFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.10 | This trap is issued when the OA100B Module's Fan Currrent parameter goes out of range. | ||
| NTF trapOA100BDResetFacDefault | 1.3.6.1.4.1.1166.6.1.2.17.0.11 | This trap is issued when the OA100B resets to factory defaults | ||
| NTF trapOA100BDStandbyMode | 1.3.6.1.4.1.1166.6.1.2.17.0.12 | This trap is issued when the OA100B is in Standby Mode. | ||
| NTF trapOA100BDOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.17.0.13 | This trap is issued when the OA100B is in Optical Input Shutdown. | ||
| NTF trapOA100BDMainTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.0.14 | This trap is issued when the OA100B is in Main TEC Temperature Shutdown. | ||
| NTF trapOA100BDAuxTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.0.15 | This trap is issued when the OA100B is in Aux TEC Temperature Shutdown. | ||
| NTF trapOA100BDKeySwitch | 1.3.6.1.4.1.1166.6.1.2.17.0.16 | This trap is issued when the Key Switch disables the OA100B. | ||
| NTF trapOA100BDPowerFail | 1.3.6.1.4.1.1166.6.1.2.17.0.17 | This trap is issued when there is an OA100B Power Supply Failure. | ||
| NTF trapOA100BDMainLasCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.0.18 | This trap is issued when the OA100B is in Main Laser Current Shutdown. | ||
| NTF trapOA100BDAuxLasCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.0.19 | This trap is issued when the OA100B is in Aux Laser Current Shutdown. | ||
| NTF trapOA100BDMainLasPowerShutdown | 1.3.6.1.4.1.1166.6.1.2.17.0.20 | This trap is issued when the OA100B is in Main Laser Power Shutdown. | ||
| NTF trapOA100BDAuxLasPowerShutdown | 1.3.6.1.4.1.1166.6.1.2.17.0.21 | This trap is issued when the OA100B is in Aux Laser Power Shutdown. | ||
| NTF trapOA100BDInvalidMode | 1.3.6.1.4.1.1166.6.1.2.17.0.22 | This trap is issued when the OA100B is in an invalid mode. | ||
| NTF trapOA100BDFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.23 | This trap is issued when the OA100B Module's boot or flash programming sequence has detected a Flash error. | ||
| NTF trapOA100BDBoot0Alarm | 1.3.6.1.4.1.1166.6.1.2.17.0.24 | This trap is issued when the OA100B Module's Bank 0 Boot sequence has detected an error. | ||
| NTF trapOA100BDBoot1Alarm | 1.3.6.1.4.1.1166.6.1.2.17.0.25 | This trap is issued when the OA100B Module's Bank 1 Boot sequence has detected an error. | ||
| NTF trapOA100BDAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.26 | This trap is issued when the OA100B Module detects an error calculating the alarm limit CRC. | ||
| NTF trapOA100BDFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.27 | This trap is issued when the OA100B Module detects an error calculating the Factory data CRC. | ||
| NTF trapOA100BDCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.28 | This trap is issued when the OA100B Module detects an error calculating the Calibration data CRC. | ||
| NTF trapOA100BDFacCalFloatAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.29 | This trap is issued when the OA100B Module detects factory calibration float data alarm. | ||
| NTF trapOA100BDOptInThreshAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.30 | This trap is issued when the OA100B Module Optical Input drops below the user set threshold. | ||
| NTF trapOA100BDGainErrorAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.31 | This trap is issued when the OA100B Module can not produce the desired user set gain in Constant Gain Set Mode. | ||
| NTF trapOA100BDHardwareErrorAlarm | 1.3.6.1.4.1.1166.6.1.2.17.0.32 | This trap is issued when any of the OA100BD Module's TEC,Laser, +12V, or +3.7V current parameters go out of range. | ||
| gx2OA100BDDescriptor | 1.3.6.1.4.1.1166.6.1.2.17.1 | |||
| gx2OA100BDAnalogTable | 1.3.6.1.4.1.1166.6.1.2.17.2 | not-accessible | This table contains gx2OA100B specific parameters with nominal and current values. | |
| gx2OA100BDAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.17.2.1 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2OA100BDAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.17.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR oa100bdlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR oa100bduomModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO oa100bdmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.8 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.10 | Float | read-only | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.11 | Float | read-only | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR oa100bdlabelOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Optical Input Power Analog parameter. |
| STR oa100bduomOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Input Power Analog parameter. |
| FLO oa100bdmajorHighOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.19 | Float | read-only | The value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.21 | Float | read-only | The value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.22 | Float | read-only | The value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateOptInPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Input Power Analog parameter. |
| STR oa100bdlabelOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Optical Output Power Analog parameter. |
| STR oa100bduomOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter. |
| FLO oa100bdmajorHighOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.30 | Float | read-only | The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.32 | Float | read-only | The value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.33 | Float | read-only | The value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateOptOutPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Output Power Analog parameter. |
| STR oa100bdlabelMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.35 | DisplayString | read-only | The value of this object provides the label of the TEC Temperature Analog parameter. |
| STR oa100bduomMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter. |
| FLO oa100bdmajorHighMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.41 | Float | read-only | The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.42 | INTEGER | read-only | The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.43 | Float | read-only | The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.44 | Float | read-only | The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateMainTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Temperature Analog parameter. |
| STR oa100bdlabelMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Main Laser Power Analog parameter. |
| STR oa100bduomMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Main Laser Power Analog parameter. |
| FLO oa100bdmajorHighMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.52 | Float | read-only | The value of this object provides the Current value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Main Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.54 | Float | read-only | The value of this object provides the minimum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.55 | Float | read-only | The value of this object provides the maximum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateMainLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Main Laser Power Analog parameter. |
| STR oa100bdlabelAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.57 | DisplayString | read-only | The value of this object provides the label of the TEC Temperature Analog parameter. |
| STR oa100bduomAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter. |
| FLO oa100bdmajorHighAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.63 | Float | read-only | The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.64 | INTEGER | read-only | The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.65 | Float | read-only | The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.66 | Float | read-only | The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateAuxTECTemp | 1.3.6.1.4.1.1166.6.1.2.17.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Temperature Analog parameter. |
| STR oa100bdlabelAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Aux Laser Power Analog parameter. |
| STR oa100bduomAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Aux Laser Power Analog parameter. |
| FLO oa100bdmajorHighAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.74 | Float | read-only | The value of this object provides the Current value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Aux Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.76 | Float | read-only | The value of this object provides the minimum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.77 | Float | read-only | The value of this object provides the maximum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateAuxLaserPower | 1.3.6.1.4.1.1166.6.1.2.17.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Aux Laser Power Analog parameter. |
| STR oa100bdlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR oa100bduomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO oa100bdmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.85 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.87 | Float | read-only | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.88 | Float | read-only | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.17.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR oa100bdlabelOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Output Power Setting Analog parameter. |
| STR oa100bduomOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO oa100bdmajorHighOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.96 | Float | read-write | The value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.98 | Float | read-only | The value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.99 | Float | read-only | The value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateOPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Output Power Setting Analog parameter. |
| STR oa100bdlabelLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.101 | DisplayString | read-only | The value of this object provides the label of the Laser Power Setting Analog parameter. |
| STR oa100bduomLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter. |
| FLO oa100bdmajorHighLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.107 | Float | read-write | The value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.108 | INTEGER | read-only | The value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.109 | Float | read-only | The value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.110 | Float | read-only | The value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateLPSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Power Setting Analog parameter. |
| STR oa100bdlabelCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.112 | DisplayString | read-only | The value of this object provides the label of the Constant Gain Setting Analog parameter. |
| STR oa100bduomCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.113 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter. |
| FLO oa100bdmajorHighCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.114 | Float | read-only | The value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.115 | Float | read-only | The value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.116 | Float | read-only | The value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.117 | Float | read-only | The value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.118 | Float | read-write | The value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.119 | INTEGER | read-only | The value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.120 | Float | read-only | The value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.121 | Float | read-only | The value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateCGSetting | 1.3.6.1.4.1.1166.6.1.2.17.2.1.122 | INTEGER | read-only | The value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter. |
| STR oa100bdlabelOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.123 | DisplayString | read-only | The value of this object provides the label of the Optical Input Threshold Analog parameter. |
| STR oa100bduomOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.124 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter. |
| FLO oa100bdmajorHighOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.125 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmajorLowOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.126 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorHighOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.127 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdminorLowOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.128 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdcurrentValueOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.129 | Float | read-write | The value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdstateFlagOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.130 | INTEGER | read-only | The value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO oa100bdminValueOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.131 | Float | read-only | The value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO oa100bdmaxValueOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.132 | Float | read-only | The value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT oa100bdalarmStateOptThreshold | 1.3.6.1.4.1.1166.6.1.2.17.2.1.133 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter. |
| gx2OA100BDDigitalTable | 1.3.6.1.4.1.1166.6.1.2.17.3 | not-accessible | This table contains gx2OA100B specific parameters with nominal and current values. | |
| gx2OA100BDDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.17.3.2 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2OA100BDDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.17.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR oa100bdlabelModeSetting | 1.3.6.1.4.1.1166.6.1.2.17.3.2.2 | DisplayString | read-only | The value of this object provides the label of the OA100BD's Mode Digital parameter. |
| STR oa100bdenumModeSetting | 1.3.6.1.4.1.1166.6.1.2.17.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
| INT oa100bdvalueModeSetting | 1.3.6.1.4.1.1166.6.1.2.17.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module. |
| INT oa100bdstateFlagModeSetting | 1.3.6.1.4.1.1166.6.1.2.17.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelModuleState | 1.3.6.1.4.1.1166.6.1.2.17.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Module State Digital parameter. |
| STR oa100bdenumModuleState | 1.3.6.1.4.1.1166.6.1.2.17.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT oa100bdvalueModuleState | 1.3.6.1.4.1.1166.6.1.2.17.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT oa100bdstateFlagModuleState | 1.3.6.1.4.1.1166.6.1.2.17.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.17.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR oa100bdenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.17.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT oa100bdvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.17.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT oa100bdstateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.17.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2OA100BDStatusTable | 1.3.6.1.4.1.1166.6.1.2.17.4 | not-accessible | This table contains gx2OA100B specific parameters with nominal and current values. | |
| gx2OA100BDStatusEntry | 1.3.6.1.4.1.1166.6.1.2.17.4.3 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2OA100BDStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.17.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR oa100bdlabelBoot | 1.3.6.1.4.1.1166.6.1.2.17.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT oa100bdvalueBoot | 1.3.6.1.4.1.1166.6.1.2.17.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.17.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelFlash | 1.3.6.1.4.1.1166.6.1.2.17.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT oa100bdvalueFlash | 1.3.6.1.4.1.1166.6.1.2.17.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.17.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT oa100bdvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| INT oa100bdvalueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| INT oa100bdvalueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.17.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Optical Input Power Shutdown Status parameter. |
| INT oa100bdvalueOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelMainTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Main TEC Temperature Shutdown Status parameter. |
| INT oa100bdvalueMainTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagMainTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelAuxTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Aux TEC Temperature Shutdown Status parameter. |
| INT oa100bdvalueAuxTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagAuxTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelPowerFail | 1.3.6.1.4.1.1166.6.1.2.17.4.3.26 | DisplayString | read-only | The value of this object provides the label of the Power Supply Fail Status parameter. |
| INT oa100bdvaluePowerFail | 1.3.6.1.4.1.1166.6.1.2.17.4.3.27 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagPowerFail | 1.3.6.1.4.1.1166.6.1.2.17.4.3.28 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelKeySwitch | 1.3.6.1.4.1.1166.6.1.2.17.4.3.29 | DisplayString | read-only | The value of this object provides the label of the Key Switch Setting Status parameter. |
| INT oa100bdvalueKeySwitch | 1.3.6.1.4.1.1166.6.1.2.17.4.3.30 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagKeySwitch | 1.3.6.1.4.1.1166.6.1.2.17.4.3.31 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelMainLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.32 | DisplayString | read-only | The value of this object provides the label of the Main Laser Current Shutdown Status parameter. |
| INT oa100bdvalueMainLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.33 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagMainLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.34 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelAuxLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.35 | DisplayString | read-only | The value of this object provides the label of the AuxLaser Current Shutdown Status parameter. |
| INT oa100bdvalueAuxLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.36 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagAuxLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.37 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelMainLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.38 | DisplayString | read-only | The value of this object provides the label of the Main Laser Power Shutdown Status parameter. |
| INT oa100bdvalueMainLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.39 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagMainLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.40 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelAuxLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.41 | DisplayString | read-only | The value of this object provides the label of the Aux Laser Power Shutdown Status parameter. |
| INT oa100bdvalueAuxLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.42 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagAuxLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.17.4.3.43 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelADCStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.44 | DisplayString | read-only | The value of this object provides the label of the ADC Operation Status parameter. |
| INT oa100bdvalueADCStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.45 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagADCStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.46 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelConstGainStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.47 | DisplayString | read-only | The value of this object provides the label of the Constant Gain Status parameter. |
| INT oa100bdvalueConstGainStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.48 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagConstGainStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.49 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelHardwareErrorStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.50 | DisplayString | read-only | The value of this object provides the label of the Hardware Error Status parameter. |
| INT oa100bdvalueHardwareErrorStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.51 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagHardwareErrorStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.52 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR oa100bdlabelStandbyStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.53 | DisplayString | read-only | The value of this object provides the label of the Standby Status parameter. |
| INT oa100bdvalueStandbyStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.54 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT oa100bdstateflagStandbyStatus | 1.3.6.1.4.1.1166.6.1.2.17.4.3.55 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2OA100BDFactoryTable | 1.3.6.1.4.1.1166.6.1.2.17.5 | not-accessible | This table contains gx2OA100B specific parameters with nominal and current values. | |
| gx2OA100BDFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.17.5.4 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2OA100BDFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.17.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT oa100bdbootControlByte | 1.3.6.1.4.1.1166.6.1.2.17.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. Boot Control Byte bit definition as follows : bit 0 : boot bit (0=boot from bank 0, 1=boot from bank 1) bit 1 : bank 0 status (0=bank is blank/bad, 1=bank is OK) bit 2 : bank 1 status (0=bank is blank/bad, 1=bank is OK) bits 3-7 : not used |
| INT oa100bdbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.17.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot Boot Status Byte bit definitions as follows: bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed boot) bit 1 : bank 1 status (0=bank is OK or not used, 1=bank failed boot) bit 2 : active bank (0=bank 0 active, 1=bank 1 active) bits 3-7: not used |
| INT oa100bdbank0CRC | 1.3.6.1.4.1.1166.6.1.2.17.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. The value is best displayed in Hex format |
| INT oa100bdbank1CRC | 1.3.6.1.4.1.1166.6.1.2.17.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. The value is best displayed in Hex format |
| INT oa100bdprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.17.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed programmed EEPROM byte definitions as follows: 0xBB = EEPROM is programmed 0xDB = EEPROM is being restored to factory defaults 0xFF = EEPROM is blank any other values are assumed to be blank EEPROM |
| INT oa100bdfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.17.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. The value is best displayed in Hex format |
| INT oa100bdcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.17.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. Calculate CRC command defintions as follows : 0x00 : recalculate factory data CRC 0x01 : recalcualte calibration table CRC 0x02 : recalculate alarm data CRC other values not defined |
| INT oa100bdhourMeter | 1.3.6.1.4.1.1166.6.1.2.17.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT oa100bdflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.17.5.4.10 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side A. |
| INT oa100bdflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.17.5.4.11 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side B. |
| STR oa100bdfwRev0 | 1.3.6.1.4.1.1166.6.1.2.17.5.4.12 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 0. This value should be displayed as two ascii characters. |
| STR oa100bdfwRev1 | 1.3.6.1.4.1.1166.6.1.2.17.5.4.13 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 1. This value should be displayed as two ascii characters. |
| gx2OA100BDHoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.17.6 | not-accessible | This table contains gx2OA100BD specific parameters with nominal and current values. | |
| gx2OA100BDHoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.17.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2OA100BDHoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.17.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT gx2OA100BDHoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.17.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT gx2OA100BDHoldTimeData | 1.3.6.1.4.1.1166.6.1.2.17.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
A SNMP MIB for OMNI (likely an acronym for a specific device family or vendor system) networking or telecommunications equipment. The GX2OA100BD designation suggests a specific device model with optical or broadband capabilities.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 OA100BD optical attenuator module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.