OMNI-gx2LME-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2LmE FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "0" Aug 28, 2006 --REVISION "1" Jul 11, 2007 Revised for HMS --REVISION "2" Jan 1, 2009 Added Fiber Length and Conditioning Unit objects -- (Used for control of LC1000E Only) --DESCRIPTION -- Added revision and description comment section -- OMNISTAR Laser Module (Forward Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2LmE Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2LmE device type. -- These parameters are common across all network elements -- from gx2LmE device type. -- -- The gx2LmE Network Elements subgroup is -- a list of gx2LmE type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2LmETableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2LmE type. -- -- Both groups are mandatory for management of gx2LmE devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2LmE Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2LmE device type. -- These parameters are common across all network elements -- from gx2LmE device type. gx2lmeDescriptor OBJECT IDENTIFIER ::= {gx2LmE 1} --***************************************************************************** -- gx2LmE Table -- Contains a list of all gx2LmE type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2lmeTableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2LmE type. gx2lmeAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2lmeAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2LmE specific parameters with nominal and current values." ::= { gx2LmE 2 } gx2lmeAnalogEntry OBJECT-TYPE SYNTAX Gx2lmeAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2lmeAnalogTableIndex } ::= { gx2lmeAnalogTable 1} --*********************************************************************** gx2lmeDigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2lmeDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2LmE specific parameters with nominal and current values." ::= { gx2LmE 3 } gx2lmeDigitalEntry OBJECT-TYPE SYNTAX Gx2lmeDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2lmeDigitalTableIndex } ::= { gx2lmeDigitalTable 2} --*********************************************************************** gx2lmeStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2lmeStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2LmE specific parameters with nominal and current values." ::= { gx2LmE 4 } gx2lmeStatusEntry OBJECT-TYPE SYNTAX Gx2lmeStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2lmeStatusTableIndex } ::= { gx2lmeStatusTable 3} --*********************************************************************** gx2lmeFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2lmeFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2LmE specific parameters with nominal and current values." ::= { gx2LmE 5 } gx2lmeFactoryEntry OBJECT-TYPE SYNTAX Gx2lmeFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2lmeFactoryTableIndex } ::= { gx2lmeFactoryTable 4} --*********************************************************************** gx2Lm1000EHoldTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Lm1000EHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Lm1000E specific parameters with nominal and current values." ::= { gx2LmE 6 } gx2Lm1000EHoldTimeEntry OBJECT-TYPE SYNTAX Gx2Lm1000EHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Lm1000EHoldTimeTableIndex, gx2Lm1000EHoldTimeSpecIndex } ::= { gx2Lm1000EHoldTimeTable 5} Gx2lmeAnalogEntry ::= SEQUENCE { gx2lmeAnalogTableIndex INTEGER, -- Analog Parameters lmelabelOffsetNomMonitor DisplayString (SIZE (0..80)), lmeuomOffsetNomMonitor DisplayString (SIZE (0..80)), lmemajorHighOffsetNomMonitor Float, lmemajorLowOffsetNomMonitor Float, lmeminorHighOffsetNomMonitor Float, lmeminorLowOffsetNomMonitor Float, lmecurrentValueOffsetNomMonitor Float, lmestateFlagOffsetNomMonitor INTEGER, lmeminValueOffsetNomMonitor Float, lmemaxValueOffsetNomMonitor Float, lmealarmStateOffsetNomMonitor INTEGER, lmelabelOffsetNomCnt DisplayString (SIZE (0..80)), lmeuomOffsetNomCnt DisplayString (SIZE (0..80)), lmemajorHighOffsetNomCnt Float, lmemajorLowOffsetNomCnt Float, lmeminorHighOffsetNomCnt Float, lmeminorLowOffsetNomCnt Float, lmecurrentValueOffsetNomCnt Float, lmestateFlagOffsetNomCnt INTEGER, lmeminValueOffsetNomCnt Float, lmemaxValueOffsetNomCnt Float, lmealarmStateOffsetNomCnt INTEGER, lmelabelRelAttenSetting DisplayString (SIZE (0..80)), lmeuomRelAttenSetting DisplayString (SIZE (0..80)), lmemajorHighRelAttenSetting Float, lmemajorLowRelAttenSetting Float, lmeminorHighRelAttenSetting Float, lmeminorLowRelAttenSetting Float, lmecurrentValueRelAttenSetting Float, lmestateFlagRelAttenSetting INTEGER, lmeminValueRelAttenSetting Float, lmemaxValueRelAttenSetting Float, lmealarmStateRelAttenSetting INTEGER, lmelabelOptPower DisplayString (SIZE (0..80)), lmeuomOptPower DisplayString (SIZE (0..80)), lmemajorHighOptPower Float, lmemajorLowOptPower Float, lmeminorHighOptPower Float, lmeminorLowOptPower Float, lmecurrentValueOptPower Float, lmestateFlagOptPower INTEGER, lmeminValueOptPower Float, lmemaxValueOptPower Float, lmealarmStateOptPower INTEGER, lmelabelLaserBias DisplayString (SIZE (0..80)), lmeuomLaserBias DisplayString (SIZE (0..80)), lmemajorHighLaserBias Float, lmemajorLowLaserBias Float, lmeminorHighLaserBias Float, lmeminorLowLaserBias Float, lmecurrentValueLaserBias Float, lmestateFlagLaserBias INTEGER, lmeminValueLaserBias Float, lmemaxValueLaserBias Float, lmealarmStateLaserBias INTEGER, lmelabelTecCurrent DisplayString (SIZE (0..80)), lmeuomTecCurrent DisplayString (SIZE (0..80)), lmemajorHighTecCurrent Float, lmemajorLowTecCurrent Float, lmeminorHighTecCurrent Float, lmeminorLowTecCurrent Float, lmecurrentValueTecCurrent Float, lmestateFlagTecCurrent INTEGER, lmeminValueTecCurrent Float, lmemaxValueTecCurrent Float, lmealarmStateTecCurrent INTEGER, lmelabelLaserTemp DisplayString (SIZE (0..80)), lmeuomLaserTemp DisplayString (SIZE (0..80)), lmemajorHighLaserTemp Float, lmemajorLowLaserTemp Float, lmeminorHighLaserTemp Float, lmeminorLowLaserTemp Float, lmecurrentValueLaserTemp Float, lmestateFlagLaserTemp INTEGER, lmeminValueLaserTemp Float, lmemaxValueLaserTemp Float, lmealarmStateLaserTemp INTEGER, lmelabelModuleTemp DisplayString (SIZE (0..80)), lmeuomModuleTemp DisplayString (SIZE (0..80)), lmemajorHighModuleTemp Float, lmemajorLowModuleTemp Float, lmeminorHighModuleTemp Float, lmeminorLowModuleTemp Float, lmecurrentValueModuleTemp Float, lmestateFlagModuleTemp INTEGER, lmeminValueModuleTemp Float, lmemaxValueModuleTemp Float, lmealarmStateModuleTemp INTEGER, lmelabelFanCurrent DisplayString (SIZE (0..80)), lmeuomFanCurrent DisplayString (SIZE (0..80)), lmemajorHighFanCurrent Float, lmemajorLowFanCurrent Float, lmeminorHighFanCurrent Float, lmeminorLowFanCurrent Float, lmecurrentValueFanCurrent Float, lmestateFlagFanCurrent INTEGER, lmeminValueFanCurrent Float, lmemaxValueFanCurrent Float, lmealarmStateFanCurrent INTEGER, lmelabel12Volt DisplayString (SIZE (0..80)), lmeuom12Volt DisplayString (SIZE (0..80)), lmemajorHigh12Volt Float, lmemajorLow12Volt Float, lmeminorHigh12Volt Float, lmeminorLow12Volt Float, lmecurrentValue12Volt Float, lmestateFlag12Volt INTEGER, lmeminValue12Volt Float, lmemaxValue12Volt Float, lmealarmState12Volt INTEGER } -- **************** Digital Parameters *********************** Gx2lmeDigitalEntry ::= SEQUENCE { gx2lmeDigitalTableIndex INTEGER, lmelabelRfInput DisplayString (SIZE (0..80)), lmeenumRfInput DisplayString (SIZE (0..80)), lmevalueRfInput INTEGER, lmestateflagRfInput INTEGER, lmelabelOptOutput DisplayString (SIZE (0..80)), lmeenumOptOutput DisplayString (SIZE (0..80)), lmevalueOptOutput INTEGER, lmestateflagOptOutput INTEGER, lmelabelLaserMode DisplayString (SIZE (0..80)), lmeenumLaserMode DisplayString (SIZE (0..80)), lmevalueLaserMode INTEGER, lmestateflagLaserMode INTEGER, lmelabelLaserSecMode DisplayString (SIZE (0..80)), lmeenumLaserSecMode DisplayString (SIZE (0..80)), lmevalueLaserSecMode INTEGER, lmestateflagLaserSecMode INTEGER, lmelabelVideoOffset DisplayString (SIZE (0..80)), lmeenumVideoOffset DisplayString (SIZE (0..80)), lmevalueVideoOffset INTEGER, lmestateflagVideoOffset INTEGER, lmelabelFactoryDefault DisplayString (SIZE (0..80)), lmeenumFactoryDefault DisplayString (SIZE (0..80)), lmevalueFactoryDefault INTEGER, lmestateflagFactoryDefault INTEGER, lmelabelFiberLength DisplayString (SIZE (0..80)), lmeenumFiberLength DisplayString (SIZE (0..80)), lmevalueFiberLength INTEGER, lmestateflagFiberLength INTEGER, lmelabelConditioningUnit DisplayString (SIZE (0..80)), lmeenumConditioningUnit DisplayString (SIZE (0..80)), lmevalueConditioningUnit INTEGER, lmestateflagConditioningUnit INTEGER } -- **************** Status Parameters ************************************ Gx2lmeStatusEntry ::= SEQUENCE { gx2lmeStatusTableIndex INTEGER, lmelabelBoot DisplayString (SIZE (0..80)), lmevalueBoot INTEGER, lmestateflagBoot INTEGER, lmelabelFlash DisplayString (SIZE (0..80)), lmevalueFlash INTEGER, lmestateflagFlash INTEGER, lmelabelFactoryDataCRC DisplayString (SIZE (0..80)), lmevalueFactoryDataCRC INTEGER, lmestateflagFactoryDataCRC INTEGER, lmelabelLaserDataCRC DisplayString (SIZE (0..80)), lmevalueLaserDataCRC INTEGER, lmestateflagLaserDataCRC INTEGER, lmelabelAlarmDataCrc DisplayString (SIZE (0..80)), lmevalueAlarmDataCrc INTEGER, lmestateflagAlarmDataCrc INTEGER, lmelabelHWStatus DisplayString (SIZE (0..80)), lmevalueHWStatus INTEGER, lmestateflagHWStatus INTEGER, lmelabelRFInputStatus DisplayString (SIZE (0..80)), lmevalueRFInputStatus INTEGER, lmestateflagRFInputStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2lmeFactoryEntry ::= SEQUENCE { gx2lmeFactoryTableIndex INTEGER, lmebootControlByteValue INTEGER, lmebootStatusByteValue INTEGER, lmebank1CRCValue INTEGER, lmebank2CRCValue INTEGER, lmeprgEEPROMByteValue INTEGER, lmefactoryCRCValue INTEGER, lmecalculateCRCValue INTEGER, lmehourMeterValue INTEGER, lmeflashPrgCntAValue INTEGER, lmeflashPrgCntBValue INTEGER, lmeflashBankARevValue DisplayString (SIZE (0..80)), lmeflashBankBRevValue DisplayString (SIZE (0..80)) } -- **************** Hold Time Parameters ************************************* Gx2Lm1000EHoldTimeEntry ::= SEQUENCE { gx2Lm1000EHoldTimeTableIndex INTEGER, gx2Lm1000EHoldTimeSpecIndex INTEGER, gx2Lm1000EHoldTimeData INTEGER } -- ************** Analog Parameters **************************** gx2lmeAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lmeAnalogEntry 1} -- New Parameter lmelabelOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Monitor Analog parameter." ::= { gx2lmeAnalogEntry 2} lmeuomOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter." ::= { gx2lmeAnalogEntry 3} lmemajorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 4} lmemajorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 5} lmeminorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 6} lmeminorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 7} lmecurrentValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 8} lmestateFlagOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2lmeAnalogEntry 9} lmeminValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 10} lmemaxValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 11} lmealarmStateOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Monitor Analog parameter." ::= { gx2lmeAnalogEntry 12} -- New Parameter lmelabelOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2lmeAnalogEntry 13} lmeuomOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2lmeAnalogEntry 14} lmemajorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 15} lmemajorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 16} lmeminorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 17} lmeminorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 18} lmecurrentValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 19} lmestateFlagOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2lmeAnalogEntry 20} lmeminValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 21} lmemaxValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 22} lmealarmStateOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Control Analog parameter." ::= { gx2lmeAnalogEntry 23} -- New Parameter lmelabelRelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Attenuator Setting Analog parameter." ::= { gx2lmeAnalogEntry 24} lmeuomRelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter." ::= { gx2lmeAnalogEntry 25} lmemajorHighRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 26} lmemajorLowRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 27} lmeminorHighRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 28} lmeminorLowRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 29} lmecurrentValueRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 30} lmestateFlagRelAttenSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 31} lmeminValueRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 32} lmemaxValueRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 33} lmealarmStateRelAttenSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter." ::= { gx2lmeAnalogEntry 34} -- New Parameter lmelabelOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2lmeAnalogEntry 35} lmeuomOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2lmeAnalogEntry 36} lmemajorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 37} lmemajorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 38} lmeminorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 39} lmeminorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 40} lmecurrentValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 41} lmestateFlagOptPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 42} lmeminValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 43} lmemaxValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 44} lmealarmStateOptPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2lmeAnalogEntry 45} -- New Parameter lmelabelLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Bias Current Analog parameter." ::= { gx2lmeAnalogEntry 46} lmeuomLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Bias Analog parameter." ::= { gx2lmeAnalogEntry 47} lmemajorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 48} lmemajorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 49} lmeminorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 50} lmeminorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 51} lmecurrentValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 52} lmestateFlagLaserBias OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 53} lmeminValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 54} lmemaxValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 55} lmealarmStateLaserBias OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Bias Analog parameter." ::= { gx2lmeAnalogEntry 56} -- New Parameter lmelabelTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2lmeAnalogEntry 57} lmeuomTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter.." ::= { gx2lmeAnalogEntry 58} lmemajorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 59} lmemajorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 60} lmeminorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 61} lmeminorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 62} lmecurrentValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 63} lmestateFlagTecCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 64} lmeminValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 65} lmemaxValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 66} lmealarmStateTecCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2lmeAnalogEntry 67} -- New Parameter lmelabelLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Temperature Analog parameter." ::= { gx2lmeAnalogEntry 68} lmeuomLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter." ::= { gx2lmeAnalogEntry 69} lmemajorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 70} lmemajorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 71} lmeminorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 72} lmeminorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 73} lmecurrentValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 74} lmestateFlagLaserTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 75} lmeminValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 76} lmemaxValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 77} lmealarmStateLaserTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Temperature Analog parameter." ::= { gx2lmeAnalogEntry 78} -- New Parameter lmelabelModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2lmeAnalogEntry 79} lmeuomModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2lmeAnalogEntry 80} lmemajorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 81} lmemajorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 82} lmeminorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 83} lmeminorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 84} lmecurrentValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 85} lmestateFlagModuleTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 86} lmeminValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 87} lmemaxValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 88} lmealarmStateModuleTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2lmeAnalogEntry 89} -- New Parameter lmelabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2lmeAnalogEntry 90} lmeuomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2lmeAnalogEntry 91} lmemajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 92} lmemajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 93} lmeminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 94} lmeminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 95} lmecurrentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 96} lmestateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 97} lmeminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 98} lmemaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 99} lmealarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2lmeAnalogEntry 100} -- New Parameter lmelabel12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2lmeAnalogEntry 101} lmeuom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2lmeAnalogEntry 102} lmemajorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 103} lmemajorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 104} lmeminorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 105} lmeminorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 106} lmecurrentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 107} lmestateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeAnalogEntry 108} lmeminValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 109} lmemaxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lmeAnalogEntry 110} lmealarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2lmeAnalogEntry 111} -- ************************ Digital parameters ********************************** gx2lmeDigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lmeDigitalEntry 1} -- New parameter lmelabelRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Control Digital parameter." ::= { gx2lmeDigitalEntry 2} lmeenumRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lmeDigitalEntry 3} lmevalueRfInput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2lmeDigitalEntry 4} lmestateflagRfInput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 5} -- New parameter lmelabelOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Control Digital parameter." ::= { gx2lmeDigitalEntry 6} lmeenumOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lmeDigitalEntry 7} lmevalueOptOutput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2lmeDigitalEntry 8} lmestateflagOptOutput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the lmestate of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 9} -- New parameter lmelabelLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Mode Digital parameter." ::= { gx2lmeDigitalEntry 10} lmeenumLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lmeDigitalEntry 11} lmevalueLaserMode OBJECT-TYPE SYNTAX INTEGER { preset(1), set(2), setEquate(3), manual(4), manualEquate(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2lmeDigitalEntry 12} lmestateflagLaserMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 13} -- New parameter lmelabelLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Secondary Mode Digital parameter." ::= { gx2lmeDigitalEntry 14} lmeenumLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lmeDigitalEntry 15} lmevalueLaserSecMode OBJECT-TYPE SYNTAX INTEGER { cw(1), video(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2lmeDigitalEntry 16} lmestateflagLaserSecMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 17} -- New parameter lmelabelVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Video Offset Digital parameter." ::= { gx2lmeDigitalEntry 18} lmeenumVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.." ::= { gx2lmeDigitalEntry 19} lmevalueVideoOffset OBJECT-TYPE SYNTAX INTEGER { minus2dB(1), minus3dB(2), minus4dB(3), minus5dB(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2lmeDigitalEntry 20} lmestateflagVideoOffset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 21} -- New parameter lmelabelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2lmeDigitalEntry 22} lmeenumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lmeDigitalEntry 23} lmevalueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2lmeDigitalEntry 24} lmestateflagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 25} -- THE OBJECTS FOR FIBER LENGTH ARE ONLY USED FOR THE LC1000 DEVICE FAMILY lmelabelFiberLength OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "This object is only used for the LC1000 device family. The value of this object provides the label for the Fiber Length Digital parameter ." ::= { gx2lmeDigitalEntry 26} lmeenumFiberLength OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "This object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 6 to 25km, where 6km is represented with a 1 and 25 with a 19." ::= { gx2lmeDigitalEntry 27} lmevalueFiberLength OBJECT-TYPE SYNTAX INTEGER { fl6km(1), fl7km(2), fl8km(3), fl9km(4), fl10km(5), fl11km(6), fl12km(7), fl13km(8), fl14km(9), fl15km(10), fl16km(11), fl17km(12), fl18km(13), fl19km(14), fl20km(15), fl21km(16), fl22km(17), fl23km(18), fl24km(19), fl25km(20) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 0 to 30 Km." ::= { gx2lmeDigitalEntry 28} lmestateflagFiberLength OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 29} -- THE OBJECTS FOR "CONDITIONING UNIT" ARE ONLY USED FOR THE LC1000 DEVICE FAMILY lmelabelConditioningUnit OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "This object is only used for the LC1000 device family. The value of this object provides the label for the Conditioning Unit Digital parameter ." ::= { gx2lmeDigitalEntry 30} lmeenumConditioningUnit OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "This object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter. " ::= { gx2lmeDigitalEntry 31} lmevalueConditioningUnit OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to normalize the output by -3db when a conditioning unit is being used in the system." ::= { gx2lmeDigitalEntry 32} lmestateflagConditioningUnit OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeDigitalEntry 33} --*********** STATUS ***************** gx2lmeStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lmeStatusEntry 1} --New Parameter lmelabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2lmeStatusEntry 2} lmevalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lmeStatusEntry 3} lmestateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeStatusEntry 4} --New Parameter lmelabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2lmeStatusEntry 5} lmevalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lmeStatusEntry 6} lmestateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeStatusEntry 7} --New Parameter lmelabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2lmeStatusEntry 8} lmevalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lmeStatusEntry 9} lmestateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeStatusEntry 10} --New Parameter lmelabelLaserDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Data CRC Status parameter." ::= { gx2lmeStatusEntry 11} lmevalueLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lmeStatusEntry 12} lmestateflagLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeStatusEntry 13} --New Parameter lmelabelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2lmeStatusEntry 14} lmevalueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lmeStatusEntry 15} lmestateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeStatusEntry 16} --New Parameter lmelabelHWStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Drive Level Status parameter." ::= { gx2lmeStatusEntry 17} lmevalueHWStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lmeStatusEntry 18} lmestateflagHWStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeStatusEntry 19} --New Parameter lmelabelRFInputStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Status parameter." ::= { gx2lmeStatusEntry 20} lmevalueRFInputStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lmeStatusEntry 21} lmestateflagRFInputStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lmeStatusEntry 22} -- ************ FACTORY DATA **************** gx2lmeFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lmeFactoryEntry 1} lmebootControlByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2lmeFactoryEntry 2} lmebootStatusByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2lmeFactoryEntry 3} lmebank1CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2lmeFactoryEntry 4} lmebank2CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2lmeFactoryEntry 5} lmeprgEEPROMByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2lmeFactoryEntry 6} lmefactoryCRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2lmeFactoryEntry 7} lmecalculateCRCValue OBJECT-TYPE SYNTAX INTEGER { factory(1), laserData(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2lmeFactoryEntry 8} lmehourMeterValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2lmeFactoryEntry 9} lmeflashPrgCntAValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2lmeFactoryEntry 10} lmeflashPrgCntBValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2lmeFactoryEntry 11} lmeflashBankARevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2lmeFactoryEntry 12} lmeflashBankBRevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2lmeFactoryEntry 13} -- ************ Hold Time DATA **************** gx2Lm1000EHoldTimeTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the index of the data object." ::= { gx2Lm1000EHoldTimeEntry 1} gx2Lm1000EHoldTimeSpecIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the index of the alarm object to be modified." ::= { gx2Lm1000EHoldTimeEntry 2} gx2Lm1000EHoldTimeData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds." ::= { gx2Lm1000EHoldTimeEntry 3} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** --*************************************************************************** -- ***********!!! THE TRAP SECTION HAS NOT BEEN COMPLETED YET !!! *********** --*************************************************************************** -- ************************************************************************** -- Laser Module traps -- ************************************************************************** trapLMEConfigChangeInteger TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapLMEConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapLMERFInputAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapLMERFOverloadAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapLMERFOffsetAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapLMEOpticalPowerAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapLMELaserBiasAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapLMELaserTempAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapLMETECCurrentAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapLMEFanCurrentAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 10 trapLME12vAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 11 trapLMEModuleTempAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Module Temperature goes out of range." ::= 12 trapLMEFlashAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 13 trapLMELaserBiasCntLoopAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation." ::= 14 trapLMEBankBootAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 15 trapLMELaserBiasCntLoopInitAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias Control loop init fails." ::= 16 trapLMERFParamInitAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RF parameter Init fails." ::= 17 trapLMETECParamInitAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Parameter Init fails." ::= 18 trapLMEAttnTableInitAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Attenuator Table Init fails." ::= 19 trapLMEPowerMeterTableInitAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Power Meter Table Init fails." ::= 20 trapLMELaserDataCRCAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Data CRC is incorrect." ::= 21 trapLMEAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 22 trapLMEFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 23 trapLMEUserRFOffAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the the User RF is turned off." ::= 24 trapLMEUserOpticalOffAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User Optical Power is turned off." ::= 25 trapLMEResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2LmE VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 26 END