All MIBs › DELL-RAC-MIB
Category: Vendor: Dell
Description: Manages Dell Remote Access Controller (RAC/iDRAC) out-of-band server management functions.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is DELL-RAC-MIB?
DELL-RAC-MIB is a Dell enterprise MIB for the Remote Access Controller (RAC), the predecessor/sibling technology to Dell's iDRAC, providing SNMP-based out-of-band management of Dell PowerEdge servers. It exposes management-and-status data for the RAC card itself and, through it, visibility into server hardware health independent of the host operating system. Its core monitoring value is hardware/software status: RAC MIBs of this class typically expose remote-access session status, firmware/version information, and links into chassis health (power supply, temperature, fan) sensors reachable via the out-of-band controller, letting administrators check server health even when the OS is down or unresponsive. It commonly complements Dell's broader OpenManage MIB-Dell-10892 chassis-health MIB, since the RAC is the out-of-band access path to that same hardware. It is deployed on Dell PowerEdge rack and blade servers as the SNMP interface to the embedded remote-access management controller. Engineers can download the DELL-RAC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in DELL-RAC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Dell PowerEdge server (via Remote Access Controller/RAC)
Monitoring Examples
No sample objects were provided for this MIB, so specific table or object names cannot be grounded to a concrete scenario; in typical Dell RAC MIB usage, an administrator would poll for RAC firmware version, active remote session count, and network configuration status to confirm out-of-band manageability of a server is intact, especially before relying on it for recovery when the host OS is unreachable.
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| dell | 1.3.6.1.4.1.674 | |||
| server3 | 1.3.6.1.4.1.674.10892 | |||
| drsOutofBandGroup | 1.3.6.1.4.1.674.10892.2 | |||
| NTF alertDrscTestTrapEvent | 1.3.6.1.4.1.674.10892.2.0.1001 | The RAC generated a test trap event in response to a user request. | ||
| NTF alertDrscAuthError | 1.3.6.1.4.1.674.10892.2.0.1002 | The RAC Authentication Failures during a time period have Exceeded a Threshold. | ||
| NTF alertDrscLostESM | 1.3.6.1.4.1.674.10892.2.0.1003 | The RAC cannot communicate with the baseboard management controller (ESM). | ||
| NTF alertDrscFoundESM | 1.3.6.1.4.1.674.10892.2.0.1004 | The RAC is communicating normally with the baseboard management controller (ESM). | ||
| NTF alertDrscPowerOff | 1.3.6.1.4.1.674.10892.2.0.1005 | The RAC has detected a System power state change to powered-off. | ||
| NTF alertDrscPowerOn | 1.3.6.1.4.1.674.10892.2.0.1006 | The RAC has detected a system power state change to powered-on. | ||
| NTF alertDrscWatchdogExpired | 1.3.6.1.4.1.674.10892.2.0.1007 | The RAC has detected that the system watchdog has expired indicating a system hang. | ||
| NTF alertDrscBattLow | 1.3.6.1.4.1.674.10892.2.0.1008 | The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes. | ||
| NTF alertDrscTempNormal | 1.3.6.1.4.1.674.10892.2.0.1009 | The RAC Temperature probe has retured to a normal value. | ||
| NTF alertDrscTempWarning | 1.3.6.1.4.1.674.10892.2.0.1010 | The RAC Temperature probe has detected a Warning value. | ||
| NTF alertDrscTempCritical | 1.3.6.1.4.1.674.10892.2.0.1011 | The RAC Temperature probe has detected a failure (or critical) value. | ||
| NTF alertDrscVoltNormal | 1.3.6.1.4.1.674.10892.2.0.1012 | The RAC voltage has returned to a normal value. | ||
| NTF alertDrscVoltWarning | 1.3.6.1.4.1.674.10892.2.0.1013 | The RAC voltage probe has detected a warning value. | ||
| NTF alertDrscVoltCritical | 1.3.6.1.4.1.674.10892.2.0.1014 | The RAC voltage probe has detected a failure (or critical) value. | ||
| NTF alertDrscSELWarning | 1.3.6.1.4.1.674.10892.2.0.1015 | The RAC has detected a new event in the System Event Log with Severity: Warning. | ||
| NTF alertDrscSELCritical | 1.3.6.1.4.1.674.10892.2.0.1016 | The RAC has detected a new event in the System Event Log with Severity: Critical. | ||
| NTF alertDrscSEL80percentFull | 1.3.6.1.4.1.674.10892.2.0.1017 | The RAC has detected that the System Event Log is 80% full. | ||
| NTF alertDrscSEL90percentFull | 1.3.6.1.4.1.674.10892.2.0.1018 | The RAC has detected that the System Event Log is 90% full. | ||
| NTF alertDrscSEL100percentFull | 1.3.6.1.4.1.674.10892.2.0.1019 | The RAC has detected that the System Event Log is 100% full. | ||
| NTF alertDrscSELNormal | 1.3.6.1.4.1.674.10892.2.0.1020 | The RAC has detected a new event in the System Event Log with Severity: Normal. | ||
| NTF alertCMCTestTrap | 1.3.6.1.4.1.674.10892.2.0.2000 | The CMC has generated a test trap | ||
| NTF alertCMCNormalTrap | 1.3.6.1.4.1.674.10892.2.0.2002 | The CMC reported a return-to-normal or informational event. | ||
| NTF alertCMCWarningTrap | 1.3.6.1.4.1.674.10892.2.0.2003 | The CMC reported a warning event. | ||
| NTF alertCMCCriticalTrap | 1.3.6.1.4.1.674.10892.2.0.2004 | The CMC reported a critical event. | ||
| NTF alertCMCNonRecoverableTrap | 1.3.6.1.4.1.674.10892.2.0.2005 | The CMC reported a catastrophic event. | ||
| drsInformationGroup | 1.3.6.1.4.1.674.10892.2.1 | |||
| drsProductInfoGroup | 1.3.6.1.4.1.674.10892.2.1.1 | |||
| STR drsProductName | 1.3.6.1.4.1.674.10892.2.1.1.1 | DellString | read-only | 0001.0001.0001 This attribute defines the product name of a chassis management controller. |
| STR drsProductShortName | 1.3.6.1.4.1.674.10892.2.1.1.2 | DellString | read-only | 0001.0001.0002 This attribute defines the short product name of a chassis management controller. |
| STR drsProductDescription | 1.3.6.1.4.1.674.10892.2.1.1.3 | DellString | read-only | 0001.0001.0003 This attribute defines the product description of a chassis management controller. |
| STR drsProductManufacturer | 1.3.6.1.4.1.674.10892.2.1.1.4 | DellString | read-only | 0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. |
| STR drsProductVersion | 1.3.6.1.4.1.674.10892.2.1.1.5 | DellString | read-only | 0001.0001.0005 This attribute defines the product version of a chassis management controller. |
| STR drsChassisServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.6 | DellString | read-only | 0001.0001.0007 This attribute defines the Service Tag of the chassis. |
| STR drsProductURL | 1.3.6.1.4.1.674.10892.2.1.1.7 | DellString | read-only | 0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. |
| STR drsProductChassisAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.8 | DellString | read-only | 0001.0001.0008 This attribute defines the Asset Tag of the chassis. |
| STR drsProductChassisLocation | 1.3.6.1.4.1.674.10892.2.1.1.9 | DellString | read-only | 0001.0001.0009 This attribute defines the location of the chassis. |
| STR drsProductChassisName | 1.3.6.1.4.1.674.10892.2.1.1.10 | DellString | read-only | 0001.0001.0010 This attribute defines the name of the chassis. |
| STR drsSystemServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.11 | DellString | read-only | 0001.0001.0011 This attribute defines the service tag of a system. |
| STR drsProductSystemAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.12 | DellString | read-only | 0001.0001.0012 This attribute defines the asset tag of a system. |
| STR drsProductSystemSlot | 1.3.6.1.4.1.674.10892.2.1.1.13 | DellString | read-only | 0001.0001.0013 This attribute defines the slot number of a CMC. |
| DEL drsProductType | 1.3.6.1.4.1.674.10892.2.1.1.14 | DellRacType | read-only | 0001.0001.0014 This attribute defines type of a remote access card |
| STR drsProductChassisDataCenter | 1.3.6.1.4.1.674.10892.2.1.1.15 | DellString | read-only | 0001.0001.0015 This attribute defines the Data Center locator of the chassis. |
| STR drsProductChassisAisle | 1.3.6.1.4.1.674.10892.2.1.1.16 | DellString | read-only | 0001.0001.0016 This attribute defines the Aisle locator of the chassis. |
| STR drsProductChassisRack | 1.3.6.1.4.1.674.10892.2.1.1.17 | DellString | read-only | 0001.0001.0017 This attribute defines the Rack locator of the chassis. |
| STR drsProductChassisRackSlot | 1.3.6.1.4.1.674.10892.2.1.1.18 | DellString | read-only | 0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. |
| STR drsProductChassisModel | 1.3.6.1.4.1.674.10892.2.1.1.19 | DellString | read-only | 0001.0001.0019 This attribute defines the Model of the chassis. |
| STR drsProductChassisExpressServiceCode | 1.3.6.1.4.1.674.10892.2.1.1.20 | DellString | read-only | 0001.0001.0020 This attribute defines the Express Service Code of the chassis. |
| INT drsProductChassisSystemID | 1.3.6.1.4.1.674.10892.2.1.1.21 | INTEGER | read-only | 0001.0001.0021 This attribute defines the System ID of the chassis. |
| INT drsProductChassisSize | 1.3.6.1.4.1.674.10892.2.1.1.22 | INTEGER | read-only | 0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component. |
| drsFirmwareGroup | 1.3.6.1.4.1.674.10892.2.1.2 | |||
| STR drsFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.1 | DellString | read-only | 0001.0002.0001 This attribute defines the firmware version of chassis management controller 1. |
| STR drsiKVMFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.2 | DellString | read-only | 0001.0002.0002 This attribute defines the firmware version of the iKVM. |
| STR drsFirmwareVersion2 | 1.3.6.1.4.1.674.10892.2.1.2.3 | DellString | read-only | 0001.0002.0003 This attribute defines the firmware version of chassis management controller 2. |
| drsStatusGroup | 1.3.6.1.4.1.674.10892.2.2 | |||
| DEL drsGlobalSystemStatus | 1.3.6.1.4.1.674.10892.2.2.1 | DellStatus | read-only | 0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
| drsChassisStatusGroup | 1.3.6.1.4.1.674.10892.2.3 | |||
| drsStatusNowGroup | 1.3.6.1.4.1.674.10892.2.3.1 | |||
| DEL drsGlobalCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.1 | DellStatus | read-only | 0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. |
| DEL drsIOMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.2 | DellStatus | read-only | 0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card. |
| DEL drsKVMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.3 | DellStatus | read-only | 0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card. |
| DEL drsRedCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.4 | DellStatus | read-only | 0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card. |
| DEL drsPowerCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.5 | DellStatus | read-only | 0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card. |
| DEL drsFanCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.6 | DellStatus | read-only | 0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card. |
| DEL drsBladeCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.7 | DellStatus | read-only | 0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card. |
| DEL drsTempCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.8 | DellStatus | read-only | 0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card. |
| DEL drsCMCCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.9 | DellStatus | read-only | 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
| DEL drsChassisFrontPanelAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.10 | DellTemperatureReading | read-only | 0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. |
| DEL drsCMCAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.11 | DellTemperatureReading | read-only | 0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card. |
| DEL drsCMCProcessorTemperature | 1.3.6.1.4.1.674.10892.2.3.1.12 | DellTemperatureReading | read-only | 0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor. |
| drsStatusPrevGroup | 1.3.6.1.4.1.674.10892.2.3.2 | |||
| DEL drsGlobalPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.1 | DellStatus | read-only | 0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card. |
| DEL drsIOMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.2 | DellStatus | read-only | 0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card. |
| DEL drsKVMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.3 | DellStatus | read-only | 0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card. |
| DEL drsRedPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.4 | DellStatus | read-only | 0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card. |
| DEL drsPowerPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.5 | DellStatus | read-only | 0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card. |
| DEL drsFanPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.6 | DellStatus | read-only | 0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card. |
| DEL drsBladePrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.7 | DellStatus | read-only | 0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card. |
| DEL drsTempPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.8 | DellStatus | read-only | 0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card. |
| DEL drsCMCPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.9 | DellStatus | read-only | 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. |
| drsStatusChangeGroup | 1.3.6.1.4.1.674.10892.2.3.3 | |||
| TIK drsGlobalChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.1 | TimeTicks | read-only | 0003.0003.0001 This attribute defines the timestamp of the most recent global status change. |
| TIK drsIOMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.2 | TimeTicks | read-only | 0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change. |
| TIK drsKVMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.3 | TimeTicks | read-only | 0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change. |
| TIK drsRedChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.4 | TimeTicks | read-only | 0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change. |
| TIK drsPowerChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.5 | TimeTicks | read-only | 0003.0003.0005 This attribute defines the timestamp of the most recent power health status change. |
| TIK drsFanChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.6 | TimeTicks | read-only | 0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change. |
| TIK drsBladeChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.7 | TimeTicks | read-only | 0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change. |
| TIK drsTempChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.8 | TimeTicks | read-only | 0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change. |
| TIK drsCMCChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.9 | TimeTicks | read-only | 0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change. |
| drsChassisPowerGroup | 1.3.6.1.4.1.674.10892.2.4 | |||
| drsCMCPowerTable | 1.3.6.1.4.1.674.10892.2.4.1 | not-accessible | 0004.0001 This object defines the CMC power table. | |
| drsCMCPowerTableEntry | 1.3.6.1.4.1.674.10892.2.4.1.1 | not-accessible | 0004.0001.0001 This object defines the CMC power table entry. | |
| DEL drsChassisIndex | 1.3.6.1.4.1.674.10892.2.4.1.1.1 | DellCMCPowerIndexRange | read-only | 0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
| DEL drsPotentialPower | 1.3.6.1.4.1.674.10892.2.4.1.1.2 | DellPowerReading | read-only | 0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers. |
| DEL drsIdlePower | 1.3.6.1.4.1.674.10892.2.4.1.1.3 | DellPowerReading | read-only | 0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers. |
| DEL drsMaxPowerSpecification | 1.3.6.1.4.1.674.10892.2.4.1.1.4 | DellPowerReading | read-only | 0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place. |
| DEL drsPowerSurplus | 1.3.6.1.4.1.674.10892.2.4.1.1.5 | DellPowerReading | read-only | 0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading. |
| DEL drsKWhCumulative | 1.3.6.1.4.1.674.10892.2.4.1.1.6 | DellPowerReading | read-only | 0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset. |
| DEL drsKWhCumulativeTime | 1.3.6.1.4.1.674.10892.2.4.1.1.7 | DellTimestamp | read-only | 0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset. |
| DEL drsWattsPeakUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.8 | DellPowerReading | read-only | 0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset. |
| DEL drsWattsPeakTime | 1.3.6.1.4.1.674.10892.2.4.1.1.9 | DellTimestamp | read-only | 0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage. |
| DEL drsWattsMinUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.10 | DellPowerReading | read-only | 0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset. |
| DEL drsWattsMinTime | 1.3.6.1.4.1.674.10892.2.4.1.1.11 | DellTimestamp | read-only | 0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage. |
| DEL drsWattsResetTime | 1.3.6.1.4.1.674.10892.2.4.1.1.12 | DellTimestamp | read-only | 0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings. |
| DEL drsWattsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.13 | DellPowerReading | read-only | 0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts). |
| DEL drsAmpsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.14 | DellPowerReading | read-only | 0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts). |
| drsCMCPSUTable | 1.3.6.1.4.1.674.10892.2.4.2 | not-accessible | 0004.0002 This object defines the CMC PSU table. | |
| drsCMCPSUTableEntry | 1.3.6.1.4.1.674.10892.2.4.2.1 | not-accessible | 0004.0002.0001 This object defines the CMC PSU table entry. | |
| DEL drsPSUChassisIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.1 | DellCMCPowerIndexRange | read-only | 0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis. |
| DEL drsPSUIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.2 | DellCMCPSUIndexRange | read-only | 0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU. |
| STR drsPSULocation | 1.3.6.1.4.1.674.10892.2.4.2.1.3 | DellString | read-only | 0004.0002.0001.0003 This attribute defines the location of the CMC PSU. |
| DEL drsPSUMonitoringCapable | 1.3.6.1.4.1.674.10892.2.4.2.1.4 | DellCMCPSUCapable | read-only | 0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location. |
| DEL drsPSUVoltsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.5 | DellPowerReading | read-only | 0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading. |
| DEL drsPSUAmpsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.6 | DellPowerReading | read-only | 0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading. |
| DEL drsPSUWattsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.7 | DellPowerReading | read-only | 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading. |
| drsChassisServerGroup | 1.3.6.1.4.1.674.10892.2.5 | |||
| drsCMCServerTable | 1.3.6.1.4.1.674.10892.2.5.1 | not-accessible | 0005.0001 This object defines the CMC server table. | |
| drsCMCServerTableEntry | 1.3.6.1.4.1.674.10892.2.5.1.1 | not-accessible | 0005.0001.0001 This object defines the CMC server table entry. | |
| DEL drsServerIndex | 1.3.6.1.4.1.674.10892.2.5.1.1.1 | DellCMCServerIndexRange | read-only | 0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server. |
| DEL drsServerMonitoringCapable | 1.3.6.1.4.1.674.10892.2.5.1.1.2 | DellCMCServerCapable | read-only | 0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location. |
| STR drsServerServiceTag | 1.3.6.1.4.1.674.10892.2.5.1.1.3 | DellString | read-only | 0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server. |
| STR drsServerSlotName | 1.3.6.1.4.1.674.10892.2.5.1.1.4 | DellString | read-only | 0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server. |
| STR drsServerSlotNumber | 1.3.6.1.4.1.674.10892.2.5.1.1.5 | DellString | read-only | 0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server. |
| STR drsServerNodeID | 1.3.6.1.4.1.674.10892.2.5.1.1.6 | DellString | read-only | 0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. |
| drsCMCAlertGroup | 1.3.6.1.4.1.674.10892.2.20 | |||
| drsChassisAlertVariables | 1.3.6.1.4.1.674.10892.2.20.10 | |||
| STR drsCASubSystem | 1.3.6.1.4.1.674.10892.2.20.10.1 | DellString | read-only | 0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert |
| DEL drsCASSCurrStatus | 1.3.6.1.4.1.674.10892.2.20.10.2 | DellStatus | read-only | 0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System |
| DEL drsCASSPrevStatus | 1.3.6.1.4.1.674.10892.2.20.10.3 | DellStatus | read-only | 0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System |
| TIK drsCASSChangeTime | 1.3.6.1.4.1.674.10892.2.20.10.4 | TimeTicks | read-only | 0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System |
| STR drsCAMessage | 1.3.6.1.4.1.674.10892.2.20.10.5 | DellString | read-only | 0020.0010.0005 This attribute defines the CSSD message of the CMC Alert |
| drsCMCAlert2Group | 1.3.6.1.4.1.674.10892.2.21 | |||
| NTF alert2FanFailure | 1.3.6.1.4.1.674.10892.2.21.0.2153 | Fan failure. | ||
| NTF alert2FanWarning | 1.3.6.1.4.1.674.10892.2.21.0.2154 | Fan warning. | ||
| NTF alert2FanInformation | 1.3.6.1.4.1.674.10892.2.21.0.2155 | Fan information. | ||
| NTF alert2TemperatureProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.2161 | Temperature sensor has detected a failure value. | ||
| NTF alert2TemperatureProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.2162 | Temperature sensor has detected a warning value. | ||
| NTF alert2TemperatureProbeNormal | 1.3.6.1.4.1.674.10892.2.21.0.2163 | Temperature sensor value is within range. | ||
| NTF alert2VoltageProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.2169 | Voltage sensor has detected a failure value. | ||
| NTF alert2VoltageProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.2170 | Voltage sensor has detected a warning value. | ||
| NTF alert2VoltageProbeNormal | 1.3.6.1.4.1.674.10892.2.21.0.2171 | Voltage sensor reading is within range. | ||
| NTF alert2AmperageProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.2177 | Current sensor has detected a failure value. | ||
| NTF alert2AmperageProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.2178 | Current sensor has detected a warning value. | ||
| NTF alert2AmperageProbeNormal | 1.3.6.1.4.1.674.10892.2.21.0.2179 | Current sensor reading is within range. | ||
| NTF alert2PowerSupplyFailure | 1.3.6.1.4.1.674.10892.2.21.0.2185 | Power supply has detected a failure. | ||
| NTF alert2PowerSupplyWarning | 1.3.6.1.4.1.674.10892.2.21.0.2186 | Power supply has detected a warning. | ||
| NTF alert2PowerSupplyNormal | 1.3.6.1.4.1.674.10892.2.21.0.2187 | Power supply has returned to normal. | ||
| NTF alert2BatteryFailure | 1.3.6.1.4.1.674.10892.2.21.0.2225 | Battery has failed or battery is absent. | ||
| NTF alert2BatteryWarning | 1.3.6.1.4.1.674.10892.2.21.0.2226 | Battery is low. | ||
| NTF alert2BatteryNormal | 1.3.6.1.4.1.674.10892.2.21.0.2227 | Battery state has returned to normal; or battery presence had been detected. | ||
| NTF alert2LinkStatusFailure | 1.3.6.1.4.1.674.10892.2.21.0.2249 | Link status failure or critical event. | ||
| NTF alert2LinkStatusWarning | 1.3.6.1.4.1.674.10892.2.21.0.2250 | Link status warning. | ||
| NTF alert2LinkStatusInformation | 1.3.6.1.4.1.674.10892.2.21.0.2251 | Link status information. | ||
| NTF alert2PowerUsageWarning | 1.3.6.1.4.1.674.10892.2.21.0.2274 | Power usage warning. | ||
| NTF alert2PowerUsageInformation | 1.3.6.1.4.1.674.10892.2.21.0.2275 | Power usage information. | ||
| NTF alert2HardwareConfigurationFailure | 1.3.6.1.4.1.674.10892.2.21.0.2329 | Hardware configuration failure or critical event. | ||
| NTF alert2HardwareConfigurationWarning | 1.3.6.1.4.1.674.10892.2.21.0.2330 | Hardware configuration warning. | ||
| NTF alert2HardwareConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.2331 | Hardware configuration information. | ||
| NTF alert2SoftwareConfigurationWarning | 1.3.6.1.4.1.674.10892.2.21.0.2338 | Software configuration warning. | ||
| NTF alert2SoftwareConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.2339 | Software configuration information. | ||
| NTF alert2SystemEventLogFailure | 1.3.6.1.4.1.674.10892.2.21.0.2377 | System Event Log failure or critical event. | ||
| NTF alert2SystemEventLogWarning | 1.3.6.1.4.1.674.10892.2.21.0.2378 | System Event Log warning. | ||
| NTF alert2SystemEventLogInformation | 1.3.6.1.4.1.674.10892.2.21.0.2379 | System Event Log information. | ||
| NTF alert2SecurityFailure | 1.3.6.1.4.1.674.10892.2.21.0.2385 | Security failure or critical event. | ||
| NTF alert2SecurityWarning | 1.3.6.1.4.1.674.10892.2.21.0.2386 | Security warning. | ||
| NTF alert2SecurityInformation | 1.3.6.1.4.1.674.10892.2.21.0.2387 | Security information. | ||
| NTF alert2CableFailure | 1.3.6.1.4.1.674.10892.2.21.0.2393 | Cable failure. | ||
| NTF alert2PCIDeviceFailure | 1.3.6.1.4.1.674.10892.2.21.0.2417 | PCI device failure or critical event. | ||
| NTF alert2PCIDeviceWarning | 1.3.6.1.4.1.674.10892.2.21.0.2418 | PCI device warning. | ||
| NTF alert2PCIDeviceInformation | 1.3.6.1.4.1.674.10892.2.21.0.2419 | PCI device information. | ||
| NTF alert2PowerSupplyAbsent | 1.3.6.1.4.1.674.10892.2.21.0.2465 | Power supply is absent. | ||
| NTF alert2RedundancyLost | 1.3.6.1.4.1.674.10892.2.21.0.2473 | Redundancy is lost. | ||
| NTF alert2RedundancyDegraded | 1.3.6.1.4.1.674.10892.2.21.0.2474 | Redundancy is degraded. | ||
| NTF alert2RedundancyInformation | 1.3.6.1.4.1.674.10892.2.21.0.2475 | Redundancy information. | ||
| NTF alert2CMCFailure | 1.3.6.1.4.1.674.10892.2.21.0.2545 | Chassis Management Controller detected an error. | ||
| NTF alert2CMCWarning | 1.3.6.1.4.1.674.10892.2.21.0.2546 | Chassis Management Controller detected a warning. | ||
| NTF alert2IOVirtualizationFailure | 1.3.6.1.4.1.674.10892.2.21.0.2553 | IO Virtualization failure or critical event. | ||
| NTF alert2IOVirtualizationWarning | 1.3.6.1.4.1.674.10892.2.21.0.2554 | IO Virtualization warning. | ||
| NTF alert2IOVirtualizationInformation | 1.3.6.1.4.1.674.10892.2.21.0.2555 | IO Virtualization information. | ||
| NTF alert2StorageManagementFailure | 1.3.6.1.4.1.674.10892.2.21.0.4177 | Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | ||
| NTF alert2StorageManagementWarning | 1.3.6.1.4.1.674.10892.2.21.0.4178 | Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | ||
| NTF alert2StorageManagementInformation | 1.3.6.1.4.1.674.10892.2.21.0.4179 | Storage Management information. There is no global status change associated with this trap. | ||
| NTF alert2StorageFanFailure | 1.3.6.1.4.1.674.10892.2.21.0.4201 | Storage Fan failure. | ||
| NTF alert2StorageFanWarning | 1.3.6.1.4.1.674.10892.2.21.0.4202 | Storage Fan warning. | ||
| NTF alert2StorageFanInformation | 1.3.6.1.4.1.674.10892.2.21.0.4203 | Storage Fan information. | ||
| NTF alert2StorageTemperatureProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.4209 | Storage Temperature probe failure. | ||
| NTF alert2StorageTemperatureProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.4210 | Storage Temperature probe warning. | ||
| NTF alert2StorageTemperatureProbeInformation | 1.3.6.1.4.1.674.10892.2.21.0.4211 | Storage Temperature probe information. | ||
| NTF alert2StoragePowerSupplyFailure | 1.3.6.1.4.1.674.10892.2.21.0.4233 | Storage Power supply failure. | ||
| NTF alert2StoragePowerSupplyWarning | 1.3.6.1.4.1.674.10892.2.21.0.4234 | Storage Power supply warning. | ||
| NTF alert2StoragePowerSupplyInformation | 1.3.6.1.4.1.674.10892.2.21.0.4235 | Storage Power supply information. | ||
| NTF alert2StorageBatteryFailure | 1.3.6.1.4.1.674.10892.2.21.0.4273 | Storage Battery failure. | ||
| NTF alert2StorageBatteryWarning | 1.3.6.1.4.1.674.10892.2.21.0.4274 | Storage Battery warning. | ||
| NTF alert2StorageBatteryInformation | 1.3.6.1.4.1.674.10892.2.21.0.4275 | Storage Battery information. | ||
| NTF alert2StorageControllerFailure | 1.3.6.1.4.1.674.10892.2.21.0.4329 | Storage Controller failure. | ||
| NTF alert2StorageControllerWarning | 1.3.6.1.4.1.674.10892.2.21.0.4330 | Storage Controller warning. | ||
| NTF alert2StorageControllerInformation | 1.3.6.1.4.1.674.10892.2.21.0.4331 | Storage Controller information. | ||
| NTF alert2StorageEnclosureFailure | 1.3.6.1.4.1.674.10892.2.21.0.4337 | Storage Enclosure failure. | ||
| NTF alert2StorageEnclosureWarning | 1.3.6.1.4.1.674.10892.2.21.0.4338 | Storage Enclosure warning. | ||
| NTF alert2StorageEnclosureInformation | 1.3.6.1.4.1.674.10892.2.21.0.4339 | Storage Enclosure information. | ||
| NTF alert2StoragePhysicalDiskFailure | 1.3.6.1.4.1.674.10892.2.21.0.4345 | Storage Physical disk failure. | ||
| NTF alert2StoragePhysicalDiskWarning | 1.3.6.1.4.1.674.10892.2.21.0.4346 | Storage Physical disk warning. | ||
| NTF alert2StoragePhysicalDiskInformation | 1.3.6.1.4.1.674.10892.2.21.0.4347 | Storage Physical disk information. | ||
| NTF alert2StorageVirtualDiskFailure | 1.3.6.1.4.1.674.10892.2.21.0.4353 | Storage Virtual disk failure. | ||
| NTF alert2StorageVirtualDiskWarning | 1.3.6.1.4.1.674.10892.2.21.0.4354 | Storage Virtual disk warning. | ||
| NTF alert2StorageVirtualDiskInformation | 1.3.6.1.4.1.674.10892.2.21.0.4355 | Storage Virtual disk information. | ||
| NTF alert2PowerSupplyAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8329 | Power Supply audit failure or critical event. | ||
| NTF alert2PowerSupplyAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8330 | Power Supply audit warning. | ||
| NTF alert2SoftwareChangeAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8361 | Software change audit failure or critical event. | ||
| NTF alert2PowerUsageAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8417 | Power usage audit failure or critical event. | ||
| NTF alert2PowerUsageAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8418 | Power usage audit warning. | ||
| NTF alert2LicenseFailure | 1.3.6.1.4.1.674.10892.2.21.0.8513 | License failure. | ||
| NTF alert2LicenseWarning | 1.3.6.1.4.1.674.10892.2.21.0.8514 | License warning. | ||
| NTF alert2LicenseInformation | 1.3.6.1.4.1.674.10892.2.21.0.8515 | License information. | ||
| NTF alert2PCIDeviceAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8562 | PCI device audit warning. | ||
| NTF alert2CMCAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8689 | Chassis Management Controller audit failure or critical event. | ||
| NTF alert2CMCAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8690 | Chassis Management Controller audit warning. | ||
| NTF alert2CMCAuditInformation | 1.3.6.1.4.1.674.10892.2.21.0.8691 | Chassis Management Controller audit information. | ||
| NTF alert2IOVirtualizationAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8698 | IO Virtualization audit warning. | ||
| NTF alert2CMCTestTrap | 1.3.6.1.4.1.674.10892.2.21.0.10395 | Test trap generated by CMC in response to a user request. | ||
| NTF alert2PCIDeviceConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.10611 | PCI device configuration information. | ||
| NTF alert2IOVConfigurationWarning | 1.3.6.1.4.1.674.10892.2.21.0.10746 | IO Virtualization configuration warning. | ||
| NTF alert2IOVConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.10747 | IO Virtualization configuration information. | ||
| drsChassisAlert2Variables | 1.3.6.1.4.1.674.10892.2.21.10 | |||
| STR drsCA2MessageID | 1.3.6.1.4.1.674.10892.2.21.10.1 | DisplayString | read-only | Message ID of the alert. |
| STR drsCA2Message | 1.3.6.1.4.1.674.10892.2.21.10.2 | DellString | read-only | Message describing the alert. |
| STR drsCA2MessageArgs | 1.3.6.1.4.1.674.10892.2.21.10.3 | DellString | read-only | Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes. |
| DEL drsCA2AlertStatus | 1.3.6.1.4.1.674.10892.2.21.10.4 | DellStatus | read-only | Status of the alert. |
| STR drsCA2FQDD | 1.3.6.1.4.1.674.10892.2.21.10.5 | DisplayString | read-only | Fully qualified device descriptor of device causing the alert. |
| drsAlertGroup | 1.3.6.1.4.1.674.10892.2.5000 | |||
| drsAlertVariables | 1.3.6.1.4.1.674.10892.2.5000.10 | |||
| OCT drsAlertSystem | 1.3.6.1.4.1.674.10892.2.5000.10.1 | OCTET STRING | read-only | 5000.0010.0001 Name of the system generating the alert. |
| OID drsAlertTableIndexOID | 1.3.6.1.4.1.674.10892.2.5000.10.2 | OBJECT IDENTIFIER | read-only | 5000.0010.0002 0.0 |
| OCT drsAlertMessage | 1.3.6.1.4.1.674.10892.2.5000.10.3 | OCTET STRING | read-only | 5000.0010.0003 Message describing the alert. |
| DEL drsAlertCurrentStatus | 1.3.6.1.4.1.674.10892.2.5000.10.4 | DellStatus | read-only | 5000.0010.0004 Current status of object causing the alert. |
| DEL drsAlertPreviousStatus | 1.3.6.1.4.1.674.10892.2.5000.10.5 | DellStatus | read-only | 5000.0010.0005 Previous status of object causing the alert. |
| OCT drsAlertData | 1.3.6.1.4.1.674.10892.2.5000.10.6 | OCTET STRING | read-only | 5000.0010.0006 Alert data. |
RFC description
Dell Remote Access Controller (RAC) management for iDRAC and CMC hardware monitoring, including power supply status, temperature readings, and system health.
Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.