DELL-RAC-MIB :: drsGlobalPrevStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › drsGlobalPrevStatus

drsGlobalPrevStatus

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::drsGlobalPrevStatus

OID (numeric): 1.3.6.1.4.1.674.10892.2.3.2.1

Node type: OBJECT-TYPE

Type: DellStatus

Access: read-only

Description: 0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card.

What is drsGlobalPrevStatus?

Reports the previous overall chassis status recorded before the most recent change, letting an admin see what the status was transitioning from - e.g. confirming a chassis moved from critical(5) to ok(3) after a repair.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.2.1
snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsGlobalPrevStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.2.1.1
snmpget -v2c -c public <target> DELL-RAC-MIB::drsGlobalPrevStatus.1

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsGlobalPrevStatus OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.3drsChassisStatusGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.3.2drsStatusPrevGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.3.2.1drsGlobalPrevStatusDELL-RAC-MIB