DELL-RAC-MIB :: drsPowerCurrStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › drsPowerCurrStatus

drsPowerCurrStatus

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::drsPowerCurrStatus

OID (numeric): 1.3.6.1.4.1.674.10892.2.3.1.5

Node type: OBJECT-TYPE

Type: DellStatus

Access: read-only

Description: 0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card.

What is drsPowerCurrStatus?

Reports the current health status of the power subsystem, aggregating PSU health so an admin can see at a glance whether the chassis's power supplies are functioning normally.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.1.5
snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsPowerCurrStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.1.5.1
snmpget -v2c -c public <target> DELL-RAC-MIB::drsPowerCurrStatus.1

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsPowerCurrStatus OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.3drsChassisStatusGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.3.1drsStatusNowGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.3.1.5drsPowerCurrStatusDELL-RAC-MIB