DELL-RAC-MIB :: drsPSUVoltsReading

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › drsPSUVoltsReading

drsPSUVoltsReading

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::drsPSUVoltsReading

OID (numeric): 1.3.6.1.4.1.674.10892.2.4.2.1.5

Node type: OBJECT-TYPE

Type: DellPowerReading

Access: read-only

Description: 0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading.

What is drsPSUVoltsReading?

Reports the instantaneous voltage reading for this PSU, letting an admin confirm the supply is delivering power within its expected voltage range.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.2.1.5
snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsPSUVoltsReading

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.2.1.5.1
snmpget -v2c -c public <target> DELL-RAC-MIB::drsPSUVoltsReading.1

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsPSUVoltsReading OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.4drsChassisPowerGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.2drsCMCPSUTableDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.2.1drsCMCPSUTableEntryDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.2.1.5drsPSUVoltsReadingDELL-RAC-MIB