All MIBs › DELL-RAC-MIB › drsTempChangeTime
drsTempChangeTime
Module: DELL-RAC-MIB
OID (symbolic): DELL-RAC-MIB::drsTempChangeTime
OID (numeric): 1.3.6.1.4.1.674.10892.2.3.3.8
Node type: OBJECT-TYPE
Type: TimeTicks
Access: read-only
Description: 0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change.
What is drsTempChangeTime?
Reports the timestamp of the most recent change in the temperature-sensor subsystem's status, to pair with drsTempCurrStatus/drsTempPrevStatus when investigating a thermal event.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.3.8 snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsTempChangeTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.3.8.1 snmpget -v2c -c public <target> DELL-RAC-MIB::drsTempChangeTime.1
Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsTempChangeTime OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.674 | dell | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10892 | server3 | DCS3FRU-MIB |
| 1.3.6.1.4.1.674.10892.2 | drsOutOfBandGroup | DCS3RMT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.674.10892.2.3 | drsChassisStatusGroup | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.3.3 | drsStatusChangeGroup | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.3.3.8 | drsTempChangeTime | DELL-RAC-MIB |