All MIBs › DELL-RAC-MIB › drsFanChangeTime
drsFanChangeTime
Module: DELL-RAC-MIB
OID (symbolic): DELL-RAC-MIB::drsFanChangeTime
OID (numeric): 1.3.6.1.4.1.674.10892.2.3.3.6
Node type: OBJECT-TYPE
Type: TimeTicks
Access: read-only
Description: 0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change.
What is drsFanChangeTime?
Reports the timestamp of the most recent change in the fan subsystem's health status, to pair with drsFanCurrStatus/drsFanPrevStatus when investigating a cooling event.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.3.6 snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsFanChangeTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.3.6.1 snmpget -v2c -c public <target> DELL-RAC-MIB::drsFanChangeTime.1
Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsFanChangeTime OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.674 | dell | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10892 | server3 | DCS3FRU-MIB |
| 1.3.6.1.4.1.674.10892.2 | drsOutOfBandGroup | DCS3RMT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.674.10892.2.3 | drsChassisStatusGroup | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.3.3 | drsStatusChangeGroup | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.3.3.6 | drsFanChangeTime | DELL-RAC-MIB |