DELL-RAC-MIB :: alertDrscVoltCritical

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › alertDrscVoltCritical

alertDrscVoltCritical

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::alertDrscVoltCritical

OID (numeric): 1.3.6.1.4.1.674.10892.2.0.1014

Node type: NOTIFICATION-TYPE

Description: The RAC voltage probe has detected a failure (or critical) value.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' DELL-RAC-MIB::alertDrscVoltCritical
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.674.10892.2.0.1014

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:64356->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (170154852) 19 days, 16:39:08.52
  SNMPv2-MIB::snmpTrapOID.0 = OID: DELL-RAC-MIB::alertDrscVoltCritical

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::alertDrscVoltCritical OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.0.1014alertDrscVoltCriticalDELL-RAC-MIB