DELL-RAC-MIB :: drsAmpsReading

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › drsAmpsReading

drsAmpsReading

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::drsAmpsReading

OID (numeric): 1.3.6.1.4.1.674.10892.2.4.1.1.14

Node type: OBJECT-TYPE

Type: DellPowerReading

Access: read-only

Description: 0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts).

What is drsAmpsReading?

Reports the instantaneous chassis current draw (note: despite the SYNTAX unit in the description text, this is an amperage reading, not watts), giving an admin a live current-draw figure alongside the wattage reading.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.1.1.14
snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsAmpsReading

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.1.1.14.1
snmpget -v2c -c public <target> DELL-RAC-MIB::drsAmpsReading.1

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsAmpsReading OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.4drsChassisPowerGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.1drsCMCPowerTableDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.1.1drsCMCPowerTableEntryDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.1.1.14drsAmpsReadingDELL-RAC-MIB