DELL-RAC-MIB :: drsProductChassisDataCenter

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › drsProductChassisDataCenter

drsProductChassisDataCenter

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::drsProductChassisDataCenter

OID (numeric): 1.3.6.1.4.1.674.10892.2.1.1.15

Node type: OBJECT-TYPE

Type: DellString

Access: read-only

Description: 0001.0001.0015 This attribute defines the Data Center locator of the chassis.

What is drsProductChassisDataCenter?

Reports the data center locator string configured for the chassis, part of a set of physical-location fields (datacenter/aisle/rack/rack-slot) admins fill in to track hardware placement across large facilities.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.1.1.15
snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsProductChassisDataCenter

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.1.1.15.1
snmpget -v2c -c public <target> DELL-RAC-MIB::drsProductChassisDataCenter.1

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsProductChassisDataCenter OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.1drsInformationGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.1.1drsProductInfoGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.1.1.15drsProductChassisDataCenterDELL-RAC-MIB