DELL-RAC-MIB :: drsRedCurrStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › drsRedCurrStatus

drsRedCurrStatus

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::drsRedCurrStatus

OID (numeric): 1.3.6.1.4.1.674.10892.2.3.1.4

Node type: OBJECT-TYPE

Type: DellStatus

Access: read-only

Description: 0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card.

What is drsRedCurrStatus?

Reports the current status of the chassis's redundancy subsystem (e.g. redundant power or CMC redundancy), warning an admin if the chassis has lost a redundant component and is now running in a non-redundant, higher-risk configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.1.4
snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsRedCurrStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.3.1.4.1
snmpget -v2c -c public <target> DELL-RAC-MIB::drsRedCurrStatus.1

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsRedCurrStatus OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.3drsChassisStatusGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.3.1drsStatusNowGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.3.1.4drsRedCurrStatusDELL-RAC-MIB