All MIBs › DELL-RAC-MIB › drsPSUWattsReading
drsPSUWattsReading
Module: DELL-RAC-MIB
OID (symbolic): DELL-RAC-MIB::drsPSUWattsReading
OID (numeric): 1.3.6.1.4.1.674.10892.2.4.2.1.7
Node type: OBJECT-TYPE
Type: DellPowerReading
Access: read-only
Description: 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading.
What is drsPSUWattsReading?
Reports the instantaneous power (wattage) draw of this specific PSU, the per-supply counterpart to the chassis-wide drsWattsReading, useful for confirming load is balanced across multiple PSUs.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.2.1.7 snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsPSUWattsReading
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.2.1.7.1 snmpget -v2c -c public <target> DELL-RAC-MIB::drsPSUWattsReading.1
Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsPSUWattsReading OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.674 | dell | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10892 | server3 | DCS3FRU-MIB |
| 1.3.6.1.4.1.674.10892.2 | drsOutOfBandGroup | DCS3RMT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.674.10892.2.4 | drsChassisPowerGroup | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.4.2 | drsCMCPSUTable | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.4.2.1 | drsCMCPSUTableEntry | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.4.2.1.7 | drsPSUWattsReading | DELL-RAC-MIB |