DELL-RAC-MIB :: drsPSUWattsReading

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-RAC-MIB › drsPSUWattsReading

drsPSUWattsReading

Module: DELL-RAC-MIB

OID (symbolic): DELL-RAC-MIB::drsPSUWattsReading

OID (numeric): 1.3.6.1.4.1.674.10892.2.4.2.1.7

Node type: OBJECT-TYPE

Type: DellPowerReading

Access: read-only

Description: 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading.

What is drsPSUWattsReading?

Reports the instantaneous power (wattage) draw of this specific PSU, the per-supply counterpart to the chassis-wide drsWattsReading, useful for confirming load is balanced across multiple PSUs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.2.1.7
snmpwalk -v2c -c public <target> DELL-RAC-MIB::drsPSUWattsReading

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.4.2.1.7.1
snmpget -v2c -c public <target> DELL-RAC-MIB::drsPSUWattsReading.1

Start monitoring Dell PowerEdge server (Remote Access Controller/RAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-RAC-MIB::drsPSUWattsReading OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (Remote Access Controller/RAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
1.3.6.1.4.1.674.10892.2drsOutOfBandGroupDCS3RMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.2.4drsChassisPowerGroupDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.2drsCMCPSUTableDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.2.1drsCMCPSUTableEntryDELL-RAC-MIB
1.3.6.1.4.1.674.10892.2.4.2.1.7drsPSUWattsReadingDELL-RAC-MIB