All MIBs › CPQCMC-MIB › cpqCmcSetupInput3FansOff
cpqCmcSetupInput3FansOff
Module: CPQCMC-MIB
OID (symbolic): CPQCMC-MIB::cpqCmcSetupInput3FansOff
OID (numeric): 1.3.6.1.4.1.232.153.2.2.2.1.2.9.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Fan switching off if Door/Sidewall 3 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off
What is cpqCmcSetupInput3FansOff?
This read-write enumerated value configures which fan(s) automatically switch off if Door/Sidewall 3 is opened: both, only fan1, only fan2, or noFan. An admin uses this to stop fans from drawing outside air or debris into the enclosure while Door 3 stands open. If opening Door 3 for maintenance should pause airflow to avoid pulling in dust, the admin sets cpqCmcSetupInput3FansOff to both(2).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.232.153.2.2.2.1.2.9.4 snmpwalk -v2c -c public <target> CPQCMC-MIB::cpqCmcSetupInput3FansOff
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.232.153.2.2.2.1.2.9.4.1 snmpget -v2c -c public <target> CPQCMC-MIB::cpqCmcSetupInput3FansOff.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.232.153.2.2.2.1.2.9.4.1 i <value>
Start monitoring Legacy Compaq (HP) Cluster/Console Management Card with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQCMC-MIB::cpqCmcSetupInput3FansOff OID value, configure state conditions and alerts, and monitor any Legacy Compaq (HP) Cluster/Console Management Card from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.153 | cpqCmc | CPQCMC-MIB |
| 1.3.6.1.4.1.232.153.2 | cpqCmcComponent | CPQCMC-MIB |
| 1.3.6.1.4.1.232.153.2.2 | cpqCmcDevice | CPQCMC-MIB |
| 1.3.6.1.4.1.232.153.2.2.2 | cpqCmcSetup | CPQCMC-MIB |
| 1.3.6.1.4.1.232.153.2.2.2.1 | cpqCmcSetupConfig | CPQCMC-MIB |
| 1.3.6.1.4.1.232.153.2.2.2.1.2 | cpqCmcSetupEvents | CPQCMC-MIB |
| 1.3.6.1.4.1.232.153.2.2.2.1.2.9 | cpqCmcSetupInput3 | CPQCMC-MIB |
| 1.3.6.1.4.1.232.153.2.2.2.1.2.9.4 | cpqCmcSetupInput3FansOff | CPQCMC-MIB |