All MIBs › ACS-MIB
Organization: Avocent Corporation
Last Updated: 2010-10-10
Category: SNA and Legacy Protocols
Description: Manages IBM ACF/VTAM network access control and SNA session parameters for legacy SNA network management.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ACS-MIB?
Despite the generic short description, the module text and object names identify this as the Avocent vendor MIB extension for the ACS 6000-series serial console/terminal servers, used to remotely manage and monitor these out-of-band access appliances. It exposes device identification objects (host name, product model, part/serial numbers, EID) along with firmware/bootcode version, dual power-supply status, and active session counts. It is squarely a hardware/software status MIB: it reports firmware and bootcode software versions, power-supply health (acsPowerSupplyStatePw1/Pw2), and the number of active console sessions, and even offers an acsReboot control object to remotely restart the unit. It is a self-contained enterprise MIB with no heavy dependency on other MIBs beyond standard SNMPv2-SMI conventions. It is typically deployed in data centers and remote sites where the ACS console server provides out-of-band serial access to other network gear, and operators poll it to confirm the console server itself is healthy. Engineers can download the ACS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ACS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Avocent ACS 6000-series console/terminal server
Monitoring Examples
An administrator would poll acsPowerSupplyStatePw1 and acsPowerSupplyStatePw2 to detect a failed redundant power supply, and check acsFirmwareVersion/acsBootcodeVersion to audit software levels across a fleet of console servers. acsActiveSessionsNumberOfSession shows how many serial/console sessions are currently open, useful for capacity planning or detecting stuck sessions. If needed, an operator can trigger acsReboot remotely, then verify recovery by re-reading acsHostName and acsSerialNumber to confirm the correct unit came back online.
What Can Be Monitored
- power supply status (dual PSU)
- firmware and bootcode version
- active console session count
- device identity (model, serial, part number)
- remote reboot control
This MIB depends on
Related MIBs
Imported Objects
From IF-MIB
| InterfaceIndex | |
| InterfaceIndexOrZero |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| IpAddress | |
| NetworkAddress | |
| TimeTicks |
From RFC1213-MIB
| PhysAddress |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| acs | 1.3.6.1.4.1.10418.16 | This module defines the Avocent MIB extensions to ACS60xx products. | ||
| acs6004 | 1.3.6.1.4.1.10418.16.1.4 | |||
| acs6008 | 1.3.6.1.4.1.10418.16.1.5 | |||
| acs6016 | 1.3.6.1.4.1.10418.16.1.1 | |||
| acs6032 | 1.3.6.1.4.1.10418.16.1.2 | |||
| acs6048 | 1.3.6.1.4.1.10418.16.1.3 | |||
| I32 acsActiveSessionsNumberOfSession | 1.3.6.1.4.1.10418.16.2.2.1 | Integer32 | read-only | Number of active sessions. |
| acsActiveSessionsTable | 1.3.6.1.4.1.10418.16.2.2.2 | not-accessible | This table contains the list of active sessions. | |
| STR acsActiveSessionsTableConnection | 1.3.6.1.4.1.10418.16.2.2.2.1.5 | DisplayString | read-only | Connection type. |
| acsActiveSessionsTableEntry | 1.3.6.1.4.1.10418.16.2.2.2.1 | not-accessible | each entry has the information about the active session | |
| STR acsActiveSessionsTableFrom | 1.3.6.1.4.1.10418.16.2.2.2.1.7 | DisplayString | read-only | The source IP address of the session. |
| STR acsActiveSessionsTableGroup | 1.3.6.1.4.1.10418.16.2.2.2.1.3 | DisplayString | read-only | The name of the group that the user belongs to. |
| NUM acsActiveSessionsTableIndex | 1.3.6.1.4.1.10418.16.2.2.2.1.1 | InterfaceIndexOrZero | read-only | A unique index representing an entry in this table. |
| INT acsActiveSessionsTableKill | 1.3.6.1.4.1.10418.16.2.2.2.1.8 | INTEGER | read-write | A set value of killSession(2) will kill the session. noAction(1) = always returned in a GET. Does nothing if SET. killSession(2)= when SET the appliance immediately kills the session. |
| STR acsActiveSessionsTableSessionTime | 1.3.6.1.4.1.10418.16.2.2.2.1.6 | DisplayString | read-only | Time of the session |
| STR acsActiveSessionsTableType | 1.3.6.1.4.1.10418.16.2.2.2.1.4 | DisplayString | read-only | The session type. |
| STR acsActiveSessionsTableUser | 1.3.6.1.4.1.10418.16.2.2.2.1.2 | DisplayString | read-only | The name of the user that opens this session. |
| acsAppliance | 1.3.6.1.4.1.10418.16.2.1 | |||
| STR acsBootcodeVersion | 1.3.6.1.4.1.10418.16.2.1.6 | DisplayString | read-only | The version of the bootcode of this appliance. |
| STR acsEIDNumber | 1.3.6.1.4.1.10418.16.2.1.5 | DisplayString | read-only | The electronic ID number (EID) of this appliance as shown on the label attached or imprinted on the appliance. |
| STR acsFirmwareVersion | 1.3.6.1.4.1.10418.16.2.1.7 | DisplayString | read-only | The version of the firmware of this appliance. |
| STR acsHostName | 1.3.6.1.4.1.10418.16.2.1.1 | DisplayString | read-only | The appliance name |
| acsManagement | 1.3.6.1.4.1.10418.16.2 | |||
| STR acsPartNumber | 1.3.6.1.4.1.10418.16.2.1.3 | DisplayString | read-only | The part number of this appliance as shown on the label attached or imprinted on the appliance. |
| acsPowerMgmt | 1.3.6.1.4.1.10418.16.2.5 | |||
| acsPowerMgmtBanksTable | 1.3.6.1.4.1.10418.16.2.5.9 | not-accessible | This table contains data monitoring of each detected bank. | |
| INT acsPowerMgmtBanksTableAlarm | 1.3.6.1.4.1.10418.16.2.5.9.1.30 | INTEGER | read-only | Show the bank alarm status. |
| NUM acsPowerMgmtBanksTableBankIndex | 1.3.6.1.4.1.10418.16.2.5.9.1.3 | InterfaceIndexOrZero | read-only | Bank index in the PDU. |
| STR acsPowerMgmtBanksTableBankName | 1.3.6.1.4.1.10418.16.2.5.9.1.4 | DisplayString | read-only | Bank name in the PDU. |
| I32 acsPowerMgmtBanksTableCurrentAvg | 1.3.6.1.4.1.10418.16.2.5.9.1.10 | Integer32 | read-only | Average value for current sensor in this bank.( A x 10 ) |
| I32 acsPowerMgmtBanksTableCurrentMax | 1.3.6.1.4.1.10418.16.2.5.9.1.8 | Integer32 | read-only | Max detected value of current sensor in this bank.( A x 10 ) |
| I32 acsPowerMgmtBanksTableCurrentMin | 1.3.6.1.4.1.10418.16.2.5.9.1.9 | Integer32 | read-only | Min detected value of current sensor in this bank.( A x 10 ) |
| INT acsPowerMgmtBanksTableCurrentReset | 1.3.6.1.4.1.10418.16.2.5.9.1.11 | INTEGER | read-write | Reset max, min and avg values of current. |
| I32 acsPowerMgmtBanksTableCurrentValue | 1.3.6.1.4.1.10418.16.2.5.9.1.7 | Integer32 | read-only | Actual value of current sensor in this bank.( A x 10 ) |
| acsPowerMgmtBanksTableEntry | 1.3.6.1.4.1.10418.16.2.5.9.1 | not-accessible | each entry has the data monitoring about bank. | |
| STR acsPowerMgmtBanksTablePduId | 1.3.6.1.4.1.10418.16.2.5.9.1.5 | DisplayString | read-only | PDU identification. |
| NUM acsPowerMgmtBanksTablePduIndex | 1.3.6.1.4.1.10418.16.2.5.9.1.2 | InterfaceIndexOrZero | read-only | A PDU position in the chain. |
| STR acsPowerMgmtBanksTablePortName | 1.3.6.1.4.1.10418.16.2.5.9.1.6 | DisplayString | read-only | Name of serial port when the PDU is connected. |
| NUM acsPowerMgmtBanksTablePortNumber | 1.3.6.1.4.1.10418.16.2.5.9.1.1 | InterfaceIndex | read-only | Number of serial port when the PDU is connected. |
| I32 acsPowerMgmtBanksTablePowerAvg | 1.3.6.1.4.1.10418.16.2.5.9.1.22 | Integer32 | read-only | Average value for power consumption in this bank.( W x 10 ) |
| I32 acsPowerMgmtBanksTablePowerFactorAvg | 1.3.6.1.4.1.10418.16.2.5.9.1.28 | Integer32 | read-only | Average value for power factor in this bank.( PF x 100 ) |
| I32 acsPowerMgmtBanksTablePowerFactorMax | 1.3.6.1.4.1.10418.16.2.5.9.1.26 | Integer32 | read-only | Max detected value of power factor in this bank.( PF x 100 ) |
| I32 acsPowerMgmtBanksTablePowerFactorMin | 1.3.6.1.4.1.10418.16.2.5.9.1.27 | Integer32 | read-only | Min detected value of power factor in this bank.( PF x 100 ) |
| INT acsPowerMgmtBanksTablePowerFactorReset | 1.3.6.1.4.1.10418.16.2.5.9.1.29 | INTEGER | read-write | Reset max, min and avg values of power factor. |
| INT acsPowerMgmtBanksTablePowerFactorType | 1.3.6.1.4.1.10418.16.2.5.9.1.24 | INTEGER | read-only | Type of power factor values. |
| I32 acsPowerMgmtBanksTablePowerFactorValue | 1.3.6.1.4.1.10418.16.2.5.9.1.25 | Integer32 | read-only | Actual value of power factor in this bank.( PF x 100 ) |
| I32 acsPowerMgmtBanksTablePowerMax | 1.3.6.1.4.1.10418.16.2.5.9.1.20 | Integer32 | read-only | Max detected value of power consumption in this bank.( W x 10 ) |
| I32 acsPowerMgmtBanksTablePowerMin | 1.3.6.1.4.1.10418.16.2.5.9.1.21 | Integer32 | read-only | Min detected value of power consumption in this bank.( W x 10 ) |
| INT acsPowerMgmtBanksTablePowerReset | 1.3.6.1.4.1.10418.16.2.5.9.1.23 | INTEGER | read-write | Reset max, min and avg values of power consumption. |
| INT acsPowerMgmtBanksTablePowerType | 1.3.6.1.4.1.10418.16.2.5.9.1.18 | INTEGER | read-only | Type of power consumption values. |
| I32 acsPowerMgmtBanksTablePowerValue | 1.3.6.1.4.1.10418.16.2.5.9.1.19 | Integer32 | read-only | Actual value of power consumption in this bank.( W x 10 ) |
| I32 acsPowerMgmtBanksTableVoltageAvg | 1.3.6.1.4.1.10418.16.2.5.9.1.16 | Integer32 | read-only | Average value for voltage sensor in this bank.( V ) |
| I32 acsPowerMgmtBanksTableVoltageMax | 1.3.6.1.4.1.10418.16.2.5.9.1.14 | Integer32 | read-only | Max detected value of voltage sensor in this bank.( V ) |
| I32 acsPowerMgmtBanksTableVoltageMin | 1.3.6.1.4.1.10418.16.2.5.9.1.15 | Integer32 | read-only | Min detected value of voltage sensor in this bank.( V ) |
| INT acsPowerMgmtBanksTableVoltageReset | 1.3.6.1.4.1.10418.16.2.5.9.1.17 | INTEGER | read-write | Reset max, min and avg values of voltage. |
| INT acsPowerMgmtBanksTableVoltageType | 1.3.6.1.4.1.10418.16.2.5.9.1.12 | INTEGER | read-only | Type of voltage values. |
| I32 acsPowerMgmtBanksTableVoltageValue | 1.3.6.1.4.1.10418.16.2.5.9.1.13 | Integer32 | read-only | Actual value of voltage sensor in this bank.( V ) |
| acsPowerMgmtEnvMonTable | 1.3.6.1.4.1.10418.16.2.5.10 | not-accessible | This table contains data monitoring of each detected environmental sensor. | |
| acsPowerMgmtEnvMonTableEntry | 1.3.6.1.4.1.10418.16.2.5.10.1 | not-accessible | each entry has the data monitoring about environmental sensors. | |
| NUM acsPowerMgmtEnvMonTableIndex | 1.3.6.1.4.1.10418.16.2.5.10.1.3 | InterfaceIndexOrZero | read-only | envmon sensor index. |
| I32 acsPowerMgmtEnvMonTableMaxValue | 1.3.6.1.4.1.10418.16.2.5.10.1.10 | Integer32 | read-only | Max detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu. |
| STR acsPowerMgmtEnvMonTableName | 1.3.6.1.4.1.10418.16.2.5.10.1.4 | DisplayString | read-only | envmon sensor name. |
| STR acsPowerMgmtEnvMonTablePduId | 1.3.6.1.4.1.10418.16.2.5.10.1.5 | DisplayString | read-only | PDU identification. |
| NUM acsPowerMgmtEnvMonTablePduIndex | 1.3.6.1.4.1.10418.16.2.5.10.1.2 | InterfaceIndexOrZero | read-only | A PDU position in the chain. |
| STR acsPowerMgmtEnvMonTablePortName | 1.3.6.1.4.1.10418.16.2.5.10.1.6 | DisplayString | read-only | Name of serial port when the PDU is connected. |
| NUM acsPowerMgmtEnvMonTablePortNumber | 1.3.6.1.4.1.10418.16.2.5.10.1.1 | InterfaceIndex | read-only | Number of serial port when the PDU is connected. |
| INT acsPowerMgmtEnvMonTableStatus | 1.3.6.1.4.1.10418.16.2.5.10.1.8 | INTEGER | read-only | Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor. |
| INT acsPowerMgmtEnvMonTableType | 1.3.6.1.4.1.10418.16.2.5.10.1.7 | INTEGER | read-only | The type of environmental monitor. |
| I32 acsPowerMgmtEnvMonTableValue | 1.3.6.1.4.1.10418.16.2.5.10.1.9 | Integer32 | read-only | Detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu. |
| acsPowerMgmtGroupTable | 1.3.6.1.4.1.10418.16.2.5.7 | not-accessible | This table contains the information about group of outlets. | |
| acsPowerMgmtGroupTableEntry | 1.3.6.1.4.1.10418.16.2.5.7.1 | not-accessible | each entry has the information about group of outlets. | |
| NUM acsPowerMgmtGroupTableIndex | 1.3.6.1.4.1.10418.16.2.5.7.1.1 | InterfaceIndexOrZero | read-only | Index of the group. |
| STR acsPowerMgmtGroupTableName | 1.3.6.1.4.1.10418.16.2.5.7.1.2 | DisplayString | read-only | Name of the group of outlets. |
| INT acsPowerMgmtGroupTablePowerControl | 1.3.6.1.4.1.10418.16.2.5.7.1.4 | INTEGER | read-write | A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. |
| INT acsPowerMgmtGroupTableStatus | 1.3.6.1.4.1.10418.16.2.5.7.1.3 | INTEGER | read-only | Status of the group of outlet. |
| I32 acsPowerMgmtNumberOfOutletGroup | 1.3.6.1.4.1.10418.16.2.5.6 | Integer32 | read-only | Number of configured group of outlets. |
| I32 acsPowerMgmtNumSerialPorts | 1.3.6.1.4.1.10418.16.2.5.1 | Integer32 | read-only | The number of Serial Ports that has PDU connected on the appliance. |
| acsPowerMgmtOutElecMonTable | 1.3.6.1.4.1.10418.16.2.5.11 | not-accessible | This table contains the information about data monitoring of outlets. | |
| INT acsPowerMgmtOutElecMonTableAlarm | 1.3.6.1.4.1.10418.16.2.5.11.1.24 | INTEGER | read-only | Show the outlet alarm status. |
| I32 acsPowerMgmtOutElecMonTableCurrentAvg | 1.3.6.1.4.1.10418.16.2.5.11.1.7 | Integer32 | read-only | Average value for outlet current sensor.( A x 10 ) |
| I32 acsPowerMgmtOutElecMonTableCurrentMax | 1.3.6.1.4.1.10418.16.2.5.11.1.5 | Integer32 | read-only | Max detected value of outlet current sensor.( A x 10 ) |
| I32 acsPowerMgmtOutElecMonTableCurrentMin | 1.3.6.1.4.1.10418.16.2.5.11.1.6 | Integer32 | read-only | Min detected value of outlet current sensor.( A x 10 ) |
| INT acsPowerMgmtOutElecMonTableCurrentReset | 1.3.6.1.4.1.10418.16.2.5.11.1.8 | INTEGER | read-write | Reset max, min and avertage values of outlet current. |
| I32 acsPowerMgmtOutElecMonTableCurrentValue | 1.3.6.1.4.1.10418.16.2.5.11.1.4 | Integer32 | read-only | Actual value of outlet current sensor.( A x 10 ) |
| acsPowerMgmtOutElecMonTableEntry | 1.3.6.1.4.1.10418.16.2.5.11.1 | not-accessible | each entry has the information about the outlet. | |
| NUM acsPowerMgmtOutElecMonTableNumber | 1.3.6.1.4.1.10418.16.2.5.11.1.3 | InterfaceIndex | read-only | Number of the outlet in the PDU. |
| NUM acsPowerMgmtOutElecMonTablePduNumber | 1.3.6.1.4.1.10418.16.2.5.11.1.2 | InterfaceIndex | read-only | Index. |
| NUM acsPowerMgmtOutElecMonTablePortNumber | 1.3.6.1.4.1.10418.16.2.5.11.1.1 | InterfaceIndex | read-only | Serial Port number. |
| I32 acsPowerMgmtOutElecMonTablePowerAvg | 1.3.6.1.4.1.10418.16.2.5.11.1.12 | Integer32 | read-only | Average value for outlet power comsumption sensor.( W x 10 ) |
| I32 acsPowerMgmtOutElecMonTablePowerFactorAvg | 1.3.6.1.4.1.10418.16.2.5.11.1.22 | Integer32 | read-only | Average value for outlet power-factor sensor.( PF x 100 ) |
| I32 acsPowerMgmtOutElecMonTablePowerFactorMax | 1.3.6.1.4.1.10418.16.2.5.11.1.20 | Integer32 | read-only | Max detected value of outlet power-factor sensor.( PF x 100 ) |
| I32 acsPowerMgmtOutElecMonTablePowerFactorMin | 1.3.6.1.4.1.10418.16.2.5.11.1.21 | Integer32 | read-only | Min detected value of outlet power-factor sensor.( PF x 100 ) |
| INT acsPowerMgmtOutElecMonTablePowerFactorReset | 1.3.6.1.4.1.10418.16.2.5.11.1.23 | INTEGER | read-write | Reset max, min and avertage values of outlet power-factor. |
| I32 acsPowerMgmtOutElecMonTablePowerFactorValue | 1.3.6.1.4.1.10418.16.2.5.11.1.19 | Integer32 | read-only | Actual value of outlet power-factor sensor.( PF x 100 ) |
| I32 acsPowerMgmtOutElecMonTablePowerMax | 1.3.6.1.4.1.10418.16.2.5.11.1.10 | Integer32 | read-only | Max detected value of outlet power comsumption sensor.( W x 10 ) |
| I32 acsPowerMgmtOutElecMonTablePowerMin | 1.3.6.1.4.1.10418.16.2.5.11.1.11 | Integer32 | read-only | Min detected value of outlet power comsumption sensor.( W x 10 ) |
| INT acsPowerMgmtOutElecMonTablePowerReset | 1.3.6.1.4.1.10418.16.2.5.11.1.13 | INTEGER | read-write | Reset max, min and avertage values of outlet power comsumption. |
| I32 acsPowerMgmtOutElecMonTablePowerValue | 1.3.6.1.4.1.10418.16.2.5.11.1.9 | Integer32 | read-only | Actual value of outlet power comsumption sensor.( W x 10 ) |
| I32 acsPowerMgmtOutElecMonTableVoltageAvg | 1.3.6.1.4.1.10418.16.2.5.11.1.17 | Integer32 | read-only | Average value for outlet voltage sensor.( V ) |
| I32 acsPowerMgmtOutElecMonTableVoltageMax | 1.3.6.1.4.1.10418.16.2.5.11.1.15 | Integer32 | read-only | Max detected value of outlet voltage sensor.( V ) |
| I32 acsPowerMgmtOutElecMonTableVoltageMin | 1.3.6.1.4.1.10418.16.2.5.11.1.16 | Integer32 | read-only | Min detected value of outlet voltage sensor.( V ) |
| INT acsPowerMgmtOutElecMonTableVoltageReset | 1.3.6.1.4.1.10418.16.2.5.11.1.18 | INTEGER | read-write | Reset max, min and avertage values of outlet voltage. |
| I32 acsPowerMgmtOutElecMonTableVoltageValue | 1.3.6.1.4.1.10418.16.2.5.11.1.14 | Integer32 | read-only | Actual value of outlet voltage sensor.( V ) |
| acsPowerMgmtOutletsTable | 1.3.6.1.4.1.10418.16.2.5.5 | not-accessible | This table contains the information about outlets. | |
| acsPowerMgmtOutletsTableEntry | 1.3.6.1.4.1.10418.16.2.5.5.1 | not-accessible | each entry has the information about the outlet. | |
| STR acsPowerMgmtOutletsTableName | 1.3.6.1.4.1.10418.16.2.5.5.1.4 | DisplayString | read-only | Name of the outlet. |
| NUM acsPowerMgmtOutletsTableNumber | 1.3.6.1.4.1.10418.16.2.5.5.1.3 | InterfaceIndex | read-only | Number of the outlet in the PDU. |
| STR acsPowerMgmtOutletsTablePduId | 1.3.6.1.4.1.10418.16.2.5.5.1.8 | DisplayString | read-only | PDU identification. |
| NUM acsPowerMgmtOutletsTablePduNumber | 1.3.6.1.4.1.10418.16.2.5.5.1.2 | InterfaceIndex | read-only | Index. |
| STR acsPowerMgmtOutletsTablePortName | 1.3.6.1.4.1.10418.16.2.5.5.1.7 | DisplayString | read-only | Serial Port Name where the PDU is connected. |
| NUM acsPowerMgmtOutletsTablePortNumber | 1.3.6.1.4.1.10418.16.2.5.5.1.1 | InterfaceIndex | read-only | Serial Port number. |
| INT acsPowerMgmtOutletsTablePowerControl | 1.3.6.1.4.1.10418.16.2.5.5.1.6 | INTEGER | read-write | A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. powerLock(5)= when SET the power lock command is sent to PDU. powerUnlock(6)=when SET the power unlock command is sent to PDU. The powerLock and powerUnlock are valid only for Cyclades-PM PDUs |
| INT acsPowerMgmtOutletsTableStatus | 1.3.6.1.4.1.10418.16.2.5.5.1.5 | INTEGER | read-only | Status of the outlet. |
| acsPowerMgmtPDUTable | 1.3.6.1.4.1.10418.16.2.5.3 | not-accessible | This table contains the list of detected PDUs. | |
| INT acsPowerMgmtPDUTableAlarm | 1.3.6.1.4.1.10418.16.2.5.3.1.62 | INTEGER | read-only | Show the PDU alarm status. |
| I32 acsPowerMgmtPDUTableCurrent1Max | 1.3.6.1.4.1.10418.16.2.5.3.1.11 | Integer32 | read-write | Maximum current of the sensor 1 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value. |
| I32 acsPowerMgmtPDUTableCurrent1Value | 1.3.6.1.4.1.10418.16.2.5.3.1.10 | Integer32 | read-only | Current of the sensor 1 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) |
| I32 acsPowerMgmtPDUTableCurrent2Max | 1.3.6.1.4.1.10418.16.2.5.3.1.13 | Integer32 | read-write | Maximum current of the sensor 2 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value. |
| I32 acsPowerMgmtPDUTableCurrent2Value | 1.3.6.1.4.1.10418.16.2.5.3.1.12 | Integer32 | read-only | Current of the sensor 2 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) |
| I32 acsPowerMgmtPDUTableCurrent3Max | 1.3.6.1.4.1.10418.16.2.5.3.1.15 | Integer32 | read-write | Maximum current of the sensor 3 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value. |
| I32 acsPowerMgmtPDUTableCurrent3Value | 1.3.6.1.4.1.10418.16.2.5.3.1.14 | Integer32 | read-only | Current of the sensor 3 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) |
| I32 acsPowerMgmtPDUTableCurrentAvg | 1.3.6.1.4.1.10418.16.2.5.3.1.42 | Integer32 | read-only | Average value for current sensor in this PDU.( A x 10 ) |
| I32 acsPowerMgmtPDUTableCurrentMax | 1.3.6.1.4.1.10418.16.2.5.3.1.40 | Integer32 | read-only | Max detected value of current sensor in this PDU.( A x 10 ) |
| I32 acsPowerMgmtPDUTableCurrentMin | 1.3.6.1.4.1.10418.16.2.5.3.1.41 | Integer32 | read-only | Min detected value of current sensor in this PDU.( A x 10 ) |
| I32 acsPowerMgmtPDUTableCurrentNOS | 1.3.6.1.4.1.10418.16.2.5.3.1.9 | Integer32 | read-only | Number of current sensors in the PDU. |
| INT acsPowerMgmtPDUTableCurrentReset | 1.3.6.1.4.1.10418.16.2.5.3.1.43 | INTEGER | read-write | Reset max, min and avg values of current. |
| I32 acsPowerMgmtPDUTableCurrentValue | 1.3.6.1.4.1.10418.16.2.5.3.1.39 | Integer32 | read-only | Actual value of current sensor in this PDU.( A x 10 ) |
| acsPowerMgmtPDUTableEntry | 1.3.6.1.4.1.10418.16.2.5.3.1 | not-accessible | each entry has the information about the PDU. | |
| I32 acsPowerMgmtPDUTableEnvSensors | 1.3.6.1.4.1.10418.16.2.5.3.1.63 | Integer32 | read-only | Number of environmental sensor in this PDU. |
| STR acsPowerMgmtPDUTableFirmwareVersion | 1.3.6.1.4.1.10418.16.2.5.3.1.7 | DisplayString | read-only | Version of the PDU firmware. |
| I32 acsPowerMgmtPDUTableHumidity1Max | 1.3.6.1.4.1.10418.16.2.5.3.1.25 | Integer32 | read-write | Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature. |
| I32 acsPowerMgmtPDUTableHumidity1Value | 1.3.6.1.4.1.10418.16.2.5.3.1.24 | Integer32 | read-only | Humidity of this PM unit . If the humidity measurement is not installed this value will be 0. |
| I32 acsPowerMgmtPDUTableHumidity2Max | 1.3.6.1.4.1.10418.16.2.5.3.1.27 | Integer32 | read-write | Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature. |
| I32 acsPowerMgmtPDUTableHumidity2Value | 1.3.6.1.4.1.10418.16.2.5.3.1.26 | Integer32 | read-only | Humidity of this PM unit . If the humidity measurement is not installed this value will be 0. |
| I32 acsPowerMgmtPDUTableHumidity3Max | 1.3.6.1.4.1.10418.16.2.5.3.1.29 | Integer32 | read-write | Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature. |
| I32 acsPowerMgmtPDUTableHumidity3Value | 1.3.6.1.4.1.10418.16.2.5.3.1.28 | Integer32 | read-only | Humidity of this PM unit . If the humidity measurement is not installed this value will be 0. |
| I32 acsPowerMgmtPDUTableHumidityNOS | 1.3.6.1.4.1.10418.16.2.5.3.1.23 | Integer32 | read-only | Number of humidity sensors in the PDU. |
| STR acsPowerMgmtPDUTableModel | 1.3.6.1.4.1.10418.16.2.5.3.1.5 | DisplayString | read-only | Model of the PDU. |
| I32 acsPowerMgmtPDUTableNumberOfBanks | 1.3.6.1.4.1.10418.16.2.5.3.1.38 | Integer32 | read-only | Number of banks of this PDU unit. |
| I32 acsPowerMgmtPDUTableNumberOfOutlets | 1.3.6.1.4.1.10418.16.2.5.3.1.8 | Integer32 | read-only | Number of outlets of the PDU. |
| INT acsPowerMgmtPDUTableNumberOfPhases | 1.3.6.1.4.1.10418.16.2.5.3.1.37 | INTEGER | read-only | Number of phases of this PDU unit. |
| STR acsPowerMgmtPDUTablePduId | 1.3.6.1.4.1.10418.16.2.5.3.1.3 | DisplayString | read-only | PDU identification. |
| NUM acsPowerMgmtPDUTablePduIndex | 1.3.6.1.4.1.10418.16.2.5.3.1.2 | InterfaceIndexOrZero | read-only | A PDU position in the chain. |
| STR acsPowerMgmtPDUTablePortName | 1.3.6.1.4.1.10418.16.2.5.3.1.4 | DisplayString | read-only | Name of serial port when the PDU is connected. |
| NUM acsPowerMgmtPDUTablePortNumber | 1.3.6.1.4.1.10418.16.2.5.3.1.1 | InterfaceIndex | read-only | Number of serial port when the PDU is connected. |
| I32 acsPowerMgmtPDUTablePowerAvg | 1.3.6.1.4.1.10418.16.2.5.3.1.54 | Integer32 | read-only | Average value for power consumption in this PDU unit.( W x 10 ) |
| I32 acsPowerMgmtPDUTablePowerFactorAvg | 1.3.6.1.4.1.10418.16.2.5.3.1.60 | Integer32 | read-only | Average value for power factor in this PDU unit.( PF x 100 ) |
| I32 acsPowerMgmtPDUTablePowerFactorMax | 1.3.6.1.4.1.10418.16.2.5.3.1.58 | Integer32 | read-only | Max detected value of power factor in this PDU unit.( PF x 100 ) |
| I32 acsPowerMgmtPDUTablePowerFactorMin | 1.3.6.1.4.1.10418.16.2.5.3.1.59 | Integer32 | read-only | Min detected value of power factor in this PDU unit.( PF x 100 ) |
| INT acsPowerMgmtPDUTablePowerFactorReset | 1.3.6.1.4.1.10418.16.2.5.3.1.61 | INTEGER | read-write | Reset max, min and avg values of power factor. |
| INT acsPowerMgmtPDUTablePowerFactorType | 1.3.6.1.4.1.10418.16.2.5.3.1.56 | INTEGER | read-only | Type of power factor values. |
| I32 acsPowerMgmtPDUTablePowerFactorValue | 1.3.6.1.4.1.10418.16.2.5.3.1.57 | Integer32 | read-only | Actual value of power factor in this PDU unit.( PF x 100 ) |
| I32 acsPowerMgmtPDUTablePowerMax | 1.3.6.1.4.1.10418.16.2.5.3.1.52 | Integer32 | read-only | Max detected value of power consumption in this PDU unit.( W x 10 ) |
| I32 acsPowerMgmtPDUTablePowerMin | 1.3.6.1.4.1.10418.16.2.5.3.1.53 | Integer32 | read-only | Min detected value of power consumption in this PDU unit.( W x 10 ) |
| INT acsPowerMgmtPDUTablePowerReset | 1.3.6.1.4.1.10418.16.2.5.3.1.55 | INTEGER | read-write | Reset max, min and avg values of power consumption. |
| INT acsPowerMgmtPDUTablePowerType | 1.3.6.1.4.1.10418.16.2.5.3.1.50 | INTEGER | read-only | Type of power consumption values.( W x 10 ) |
| I32 acsPowerMgmtPDUTablePowerValue | 1.3.6.1.4.1.10418.16.2.5.3.1.51 | Integer32 | read-only | Actual value of power consumption in this PDU unit.( W x 10 ) |
| I32 acsPowerMgmtPDUTableTemperature1Max | 1.3.6.1.4.1.10418.16.2.5.3.1.18 | Integer32 | read-write | Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature. |
| I32 acsPowerMgmtPDUTableTemperature1Value | 1.3.6.1.4.1.10418.16.2.5.3.1.17 | Integer32 | read-only | Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). |
| I32 acsPowerMgmtPDUTableTemperature2Max | 1.3.6.1.4.1.10418.16.2.5.3.1.20 | Integer32 | read-write | Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature. |
| I32 acsPowerMgmtPDUTableTemperature2Value | 1.3.6.1.4.1.10418.16.2.5.3.1.19 | Integer32 | read-only | Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). |
| I32 acsPowerMgmtPDUTableTemperature3Max | 1.3.6.1.4.1.10418.16.2.5.3.1.22 | Integer32 | read-write | Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature. |
| I32 acsPowerMgmtPDUTableTemperature3Value | 1.3.6.1.4.1.10418.16.2.5.3.1.21 | Integer32 | read-only | Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). |
| I32 acsPowerMgmtPDUTableTemperatureNOS | 1.3.6.1.4.1.10418.16.2.5.3.1.16 | Integer32 | read-only | Number of temperature sensors in the PDU. |
| STR acsPowerMgmtPDUTableVendor | 1.3.6.1.4.1.10418.16.2.5.3.1.6 | DisplayString | read-only | Vendor of the PDU. |
| I32 acsPowerMgmtPDUTableVoltage1Max | 1.3.6.1.4.1.10418.16.2.5.3.1.32 | Integer32 | read-write | Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. |
| I32 acsPowerMgmtPDUTableVoltage1Value | 1.3.6.1.4.1.10418.16.2.5.3.1.31 | Integer32 | read-only | Voltage of this sensor in this PDU unit. |
| I32 acsPowerMgmtPDUTableVoltage2Max | 1.3.6.1.4.1.10418.16.2.5.3.1.34 | Integer32 | read-write | Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. |
| I32 acsPowerMgmtPDUTableVoltage2Value | 1.3.6.1.4.1.10418.16.2.5.3.1.33 | Integer32 | read-only | Voltage of this sensor in this PDU unit. |
| I32 acsPowerMgmtPDUTableVoltage3Max | 1.3.6.1.4.1.10418.16.2.5.3.1.36 | Integer32 | read-write | Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage. |
| I32 acsPowerMgmtPDUTableVoltage3Value | 1.3.6.1.4.1.10418.16.2.5.3.1.35 | Integer32 | read-only | Voltage of this sensor in this PDU unit. |
| I32 acsPowerMgmtPDUTableVoltageAvg | 1.3.6.1.4.1.10418.16.2.5.3.1.48 | Integer32 | read-only | Average value for voltage sensor in this PDU unit.( V ) |
| I32 acsPowerMgmtPDUTableVoltageMax | 1.3.6.1.4.1.10418.16.2.5.3.1.46 | Integer32 | read-only | Max detected value of voltage sensor in this PDU unit.( V ) |
| I32 acsPowerMgmtPDUTableVoltageMin | 1.3.6.1.4.1.10418.16.2.5.3.1.47 | Integer32 | read-only | Min detected value of voltage sensor in this PDU unit.( V ) |
| I32 acsPowerMgmtPDUTableVoltageNOS | 1.3.6.1.4.1.10418.16.2.5.3.1.30 | Integer32 | read-only | Number of voltage sensors in the PDU. |
| INT acsPowerMgmtPDUTableVoltageReset | 1.3.6.1.4.1.10418.16.2.5.3.1.49 | INTEGER | read-write | Reset max, min and avg values of voltage. |
| INT acsPowerMgmtPDUTableVoltageType | 1.3.6.1.4.1.10418.16.2.5.3.1.44 | INTEGER | read-only | Type of voltage values. |
| I32 acsPowerMgmtPDUTableVoltageValue | 1.3.6.1.4.1.10418.16.2.5.3.1.45 | Integer32 | read-only | Actual value of voltage sensor in this PDU unit.( V ) |
| acsPowerMgmtPhasesTable | 1.3.6.1.4.1.10418.16.2.5.8 | not-accessible | This table contains data monitoring of each detected phase. | |
| INT acsPowerMgmtPhasesTableAlarm | 1.3.6.1.4.1.10418.16.2.5.8.1.30 | INTEGER | read-only | Show the phase alarm status. |
| I32 acsPowerMgmtPhasesTableCurrentAvg | 1.3.6.1.4.1.10418.16.2.5.8.1.10 | Integer32 | read-only | Average value for current sensor in this phase.( A x 10 ) |
| I32 acsPowerMgmtPhasesTableCurrentMax | 1.3.6.1.4.1.10418.16.2.5.8.1.8 | Integer32 | read-only | Max detected value of current sensor in this phase.( A x 10 ) |
| I32 acsPowerMgmtPhasesTableCurrentMin | 1.3.6.1.4.1.10418.16.2.5.8.1.9 | Integer32 | read-only | Min detected value of current sensor in this phase.( A x 10 ) |
| INT acsPowerMgmtPhasesTableCurrentReset | 1.3.6.1.4.1.10418.16.2.5.8.1.11 | INTEGER | read-write | Reset max, min and avg values of current. |
| I32 acsPowerMgmtPhasesTableCurrentValue | 1.3.6.1.4.1.10418.16.2.5.8.1.7 | Integer32 | read-only | Actual value of current sensor in this phase.( A x 10 ) |
| acsPowerMgmtPhasesTableEntry | 1.3.6.1.4.1.10418.16.2.5.8.1 | not-accessible | each entry has the data monitoring about phases. | |
| STR acsPowerMgmtPhasesTablePduId | 1.3.6.1.4.1.10418.16.2.5.8.1.5 | DisplayString | read-only | PDU identification. |
| NUM acsPowerMgmtPhasesTablePduIndex | 1.3.6.1.4.1.10418.16.2.5.8.1.2 | InterfaceIndexOrZero | read-only | A PDU position in the chain. |
| NUM acsPowerMgmtPhasesTablePhaseIndex | 1.3.6.1.4.1.10418.16.2.5.8.1.3 | InterfaceIndexOrZero | read-only | phase index in the PDU. |
| STR acsPowerMgmtPhasesTablePhaseName | 1.3.6.1.4.1.10418.16.2.5.8.1.4 | DisplayString | read-only | phase name in the PDU. |
| STR acsPowerMgmtPhasesTablePortName | 1.3.6.1.4.1.10418.16.2.5.8.1.6 | DisplayString | read-only | Name of serial port when the PDU is connected. |
| NUM acsPowerMgmtPhasesTablePortNumber | 1.3.6.1.4.1.10418.16.2.5.8.1.1 | InterfaceIndex | read-only | Number of serial port when the PDU is connected. |
| I32 acsPowerMgmtPhasesTablePowerAvg | 1.3.6.1.4.1.10418.16.2.5.8.1.22 | Integer32 | read-only | Average value for power consumption in this phase.( W x 10 ) |
| I32 acsPowerMgmtPhasesTablePowerFactorAvg | 1.3.6.1.4.1.10418.16.2.5.8.1.28 | Integer32 | read-only | Average value for power factor in this phase.( PF x 100 ) |
| I32 acsPowerMgmtPhasesTablePowerFactorMax | 1.3.6.1.4.1.10418.16.2.5.8.1.26 | Integer32 | read-only | Max detected value of power factor in this phase.( PF x 100 ) |
| I32 acsPowerMgmtPhasesTablePowerFactorMin | 1.3.6.1.4.1.10418.16.2.5.8.1.27 | Integer32 | read-only | Min detected value of power factor in this phase.( PF x 100 ) |
| INT acsPowerMgmtPhasesTablePowerFactorReset | 1.3.6.1.4.1.10418.16.2.5.8.1.29 | INTEGER | read-write | Reset max, min and avg values of power factor. |
| INT acsPowerMgmtPhasesTablePowerFactorType | 1.3.6.1.4.1.10418.16.2.5.8.1.24 | INTEGER | read-only | Type of power factor values. |
| I32 acsPowerMgmtPhasesTablePowerFactorValue | 1.3.6.1.4.1.10418.16.2.5.8.1.25 | Integer32 | read-only | Actual value of power factor in this phase.( PF x 100 ) |
| I32 acsPowerMgmtPhasesTablePowerMax | 1.3.6.1.4.1.10418.16.2.5.8.1.20 | Integer32 | read-only | Max detected value of power consumption in this phase.( W x 10 ) |
| I32 acsPowerMgmtPhasesTablePowerMin | 1.3.6.1.4.1.10418.16.2.5.8.1.21 | Integer32 | read-only | Min detected value of power consumption in this phase.( W x 10 ) |
| INT acsPowerMgmtPhasesTablePowerReset | 1.3.6.1.4.1.10418.16.2.5.8.1.23 | INTEGER | read-write | Reset max, min and avg values of power consumption. |
| INT acsPowerMgmtPhasesTablePowerType | 1.3.6.1.4.1.10418.16.2.5.8.1.18 | INTEGER | read-only | Type of power consumption values. |
| I32 acsPowerMgmtPhasesTablePowerValue | 1.3.6.1.4.1.10418.16.2.5.8.1.19 | Integer32 | read-only | Actual value of power consumption in this phase.( W x 10 ) |
| I32 acsPowerMgmtPhasesTableVoltageAvg | 1.3.6.1.4.1.10418.16.2.5.8.1.16 | Integer32 | read-only | Average value for voltage sensor in this phase.( V ) |
| I32 acsPowerMgmtPhasesTableVoltageMax | 1.3.6.1.4.1.10418.16.2.5.8.1.14 | Integer32 | read-only | Max detected value of voltage sensor in this phase.( V ) |
| I32 acsPowerMgmtPhasesTableVoltageMin | 1.3.6.1.4.1.10418.16.2.5.8.1.15 | Integer32 | read-only | Min detected value of voltage sensor in this phase.( V ) |
| INT acsPowerMgmtPhasesTableVoltageReset | 1.3.6.1.4.1.10418.16.2.5.8.1.17 | INTEGER | read-write | Reset max, min and avg values of voltage. |
| INT acsPowerMgmtPhasesTableVoltageType | 1.3.6.1.4.1.10418.16.2.5.8.1.12 | INTEGER | read-only | Type of voltage values. |
| I32 acsPowerMgmtPhasesTableVoltageValue | 1.3.6.1.4.1.10418.16.2.5.8.1.13 | Integer32 | read-only | Actual value of voltage sensor in this phase.( V ) |
| acsPowerMgmtSerialTable | 1.3.6.1.4.1.10418.16.2.5.2 | not-accessible | Information about each serial port thas has PDU connect. | |
| STR acsPowerMgmtSerialTableDeviceName | 1.3.6.1.4.1.10418.16.2.5.2.1.3 | DisplayString | read-only | The device name of this serial port. |
| acsPowerMgmtSerialTableEntry | 1.3.6.1.4.1.10418.16.2.5.2.1 | not-accessible | Information about each serial port thas has PDU connect. | |
| NUM acsPowerMgmtSerialTableIndex | 1.3.6.1.4.1.10418.16.2.5.2.1.1 | InterfaceIndex | read-only | The index of the register. |
| I32 acsPowerMgmtSerialTableNumberPDUs | 1.3.6.1.4.1.10418.16.2.5.2.1.4 | Integer32 | read-only | Total number of units connected in this serial port. |
| I32 acsPowerMgmtSerialTablePortNumber | 1.3.6.1.4.1.10418.16.2.5.2.1.2 | Integer32 | read-only | The number of the serial port when the PDU is connected. |
| I32 acsPowerMgmtTotalNumberOfOutlets | 1.3.6.1.4.1.10418.16.2.5.4 | Integer32 | read-only | Number of outlets managed by the appliance. |
| acsPowerSupply | 1.3.6.1.4.1.10418.16.2.1.8 | It gives information about Power Supply of this appliance | ||
| I32 acsPowerSupplyNumber | 1.3.6.1.4.1.10418.16.2.1.8.1 | Integer32 | read-only | Number of the power supplies of this appliance |
| POW acsPowerSupplyStatePw1 | 1.3.6.1.4.1.10418.16.2.1.8.2 | PowerSupplyState | read-only | State of the first power supply |
| POW acsPowerSupplyStatePw2 | 1.3.6.1.4.1.10418.16.2.1.8.3 | PowerSupplyState | read-only | State of the second power supply |
| STR acsProductModel | 1.3.6.1.4.1.10418.16.2.1.2 | DisplayString | read-only | The appliance product model |
| acsProducts | 1.3.6.1.4.1.10418.16.1 | |||
| INT acsReboot | 1.3.6.1.4.1.10418.16.2.1.9 | INTEGER | read-write | A set value of reboot(2) will reboot the appliance. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the appliance immediately reboots. |
| STR acsSerialNumber | 1.3.6.1.4.1.10418.16.2.1.4 | DisplayString | read-only | The serial number of this appliance as shown on the label attached or imprinted on the appliance. |
| acsSerialPort | 1.3.6.1.4.1.10418.16.2.3 | |||
| I32 acsSerialPortNumberOfPorts | 1.3.6.1.4.1.10418.16.2.3.1 | Integer32 | read-only | Number of Serial Ports (physical serial port plus Aux Port. |
| acsSerialPortTable | 1.3.6.1.4.1.10418.16.2.3.2 | not-accessible | This table contains information about serial ports. | |
| I32 acsSerialPortTableBreak | 1.3.6.1.4.1.10418.16.2.3.2.1.20 | Integer32 | read-only | The number of break detected in the serial port. |
| I32 acsSerialPortTableComDataSize | 1.3.6.1.4.1.10418.16.2.3.2.1.9 | Integer32 | read-only | Data Size configured for this serial port. |
| INT acsSerialPortTableComFlowControl | 1.3.6.1.4.1.10418.16.2.3.2.1.11 | INTEGER | read-only | Flow Control configured for this serial port. |
| INT acsSerialPortTableComParity | 1.3.6.1.4.1.10418.16.2.3.2.1.8 | INTEGER | read-only | Parity configured for this serial port. |
| SER acsSerialPortTableComSpeed | 1.3.6.1.4.1.10418.16.2.3.2.1.7 | SerialPortSpeed | read-only | Speed configured for this serial port. |
| I32 acsSerialPortTableComStopBits | 1.3.6.1.4.1.10418.16.2.3.2.1.10 | Integer32 | read-only | Number of Stop Bits configured for this serial port. |
| STR acsSerialPortTableDeviceName | 1.3.6.1.4.1.10418.16.2.3.2.1.2 | DisplayString | read-only | The associated device name for the serial port. |
| acsSerialPortTableEntry | 1.3.6.1.4.1.10418.16.2.3.2.1 | not-accessible | each entry has the information about specific serial port. | |
| I32 acsSerialPortTableFrameError | 1.3.6.1.4.1.10418.16.2.3.2.1.18 | Integer32 | read-only | The number of frame error detected in the serial port. |
| STR acsSerialPortTableName | 1.3.6.1.4.1.10418.16.2.3.2.1.4 | DisplayString | read-only | Name associated with this serial port. |
| I32 acsSerialPortTableNumber | 1.3.6.1.4.1.10418.16.2.3.2.1.1 | Integer32 | read-only | A unique index representing an entry in this table. It is the number of the serial port. For AUX port, the number will be the number of physical serial ports plus 1. |
| I32 acsSerialPortTableOverrun | 1.3.6.1.4.1.10418.16.2.3.2.1.21 | Integer32 | read-only | The number of overrun error detected in the serial port. |
| I32 acsSerialPortTableParityError | 1.3.6.1.4.1.10418.16.2.3.2.1.19 | Integer32 | read-only | The number of parity error detected in the serial port. |
| SER acsSerialPortTablePinOut | 1.3.6.1.4.1.10418.16.2.3.2.1.6 | SerialPortPinOut | read-only | RJ45 Pin-out configured for this serial port. |
| INT acsSerialPortTableProfile | 1.3.6.1.4.1.10418.16.2.3.2.1.5 | INTEGER | read-only | Configured profile for this serial port. |
| I32 acsSerialPortTableRxBytes | 1.3.6.1.4.1.10418.16.2.3.2.1.17 | Integer32 | read-only | The number of received bytes by the serial port. |
| SER acsSerialPortTableSignalStateCTS | 1.3.6.1.4.1.10418.16.2.3.2.1.15 | SerialPortSignalState | read-only | State of the CTS RS-232C signal. |
| SER acsSerialPortTableSignalStateDCD | 1.3.6.1.4.1.10418.16.2.3.2.1.13 | SerialPortSignalState | read-only | State of the DCD RS-232C signal. |
| SER acsSerialPortTableSignalStateDTR | 1.3.6.1.4.1.10418.16.2.3.2.1.12 | SerialPortSignalState | read-only | State of the DTR RS-232C signal. |
| SER acsSerialPortTableSignalStateRTS | 1.3.6.1.4.1.10418.16.2.3.2.1.14 | SerialPortSignalState | read-only | State of the RTS RS-232C signal. |
| INT acsSerialPortTableStatus | 1.3.6.1.4.1.10418.16.2.3.2.1.3 | INTEGER | read-only | The status of the serial port: disabled(1) = it was configured as disable. idle(2) = there is not any session opened in this port. inUse(3) = there is session(s) opened in this port. |
| I32 acsSerialPortTableTxBytes | 1.3.6.1.4.1.10418.16.2.3.2.1.16 | Integer32 | read-only | The number of transmited bytes by the serial port. |
| acsSessions | 1.3.6.1.4.1.10418.16.2.2 | |||
| acsTrapObject | 1.3.6.1.4.1.10418.16.2.6 |
RFC description
Avocent ACS 60xx appliance management including sessions, power, and serial ports.
Start monitoring Avocent console/terminal servers with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.