ACS-MIB :: acsPowerMgmtPDUTableTemperature3Max

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACS-MIBacsPowerMgmtPDUTableTemperature3Max

acsPowerMgmtPDUTableTemperature3Max

Module: ACS-MIB

OID (symbolic): ACS-MIB::acsPowerMgmtPDUTableTemperature3Max

OID (numeric): 1.3.6.1.4.1.10418.16.2.5.3.1.22

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.

What is acsPowerMgmtPDUTableTemperature3Max?

This OID stores the highest temperature ever recorded at sensor location 3 as tenths of degrees Celsius and can be cleared by resetting to zero. Engineers use this to track long-term thermal trends across all three zones and to validate that no single location is chronically hot. For instance, if location 3 peaked at 595 (59.5°C) but locations 1 and 2 stayed below 45°C, it suggests a localized blockage in airflow at that spot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10418.16.2.5.3.1.22
snmpwalk -v2c -c public <target> ACS-MIB::acsPowerMgmtPDUTableTemperature3Max

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10418.16.2.5.3.1.22.1
snmpget -v2c -c public <target> ACS-MIB::acsPowerMgmtPDUTableTemperature3Max.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10418.16.2.5.3.1.22.1 i <value>

Start monitoring Avocent console/terminal servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACS-MIB::acsPowerMgmtPDUTableTemperature3Max OID value, configure state conditions and alerts, and monitor any Avocent console/terminal servers from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10418.16acsACS-MIB
1.3.6.1.4.1.10418.16.2acsManagementACS-MIB
1.3.6.1.4.1.10418.16.2.5acsPowerMgmtACS-MIB
1.3.6.1.4.1.10418.16.2.5.3acsPowerMgmtPDUTableACS-MIB
1.3.6.1.4.1.10418.16.2.5.3.1acsPowerMgmtPDUTableEntryACS-MIB
1.3.6.1.4.1.10418.16.2.5.3.1.22acsPowerMgmtPDUTableTemperature3MaxACS-MIB