All MIBs › OMNI-gx2EDFA-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 EDFA erbium-doped fiber amplifier module in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2EDFA-MIB?
OMNI-gx2EDFA-MIB is a Cisco/Scientific-Atlanta MIB for the GX2 EDFA (erbium-doped fiber amplifier) module used in hybrid fiber-coax (HFC) optical nodes in cable TV/broadband networks. It is used to monitor and configure the optical amplifier module's operating parameters and hardware health rather than any networking/routing data. Its central use is hardware status monitoring: optical output power, pump laser status/temperature, and module alarm/fault conditions that indicate amplifier degradation or failure, which directly affects downstream signal quality for subscribers on that node. As part of Cisco's HFC/optical-node product family it likely shares enterprise MIB conventions with other Scientific-Atlanta/Cisco cable-plant equipment MIBs (e.g. environmental/inventory MIBs for the node chassis). It is deployed in cable operator HFC plants, at optical nodes housing a GX2 EDFA amplifier module. Engineers can download the OMNI-gx2EDFA-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2EDFA-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco/Scientific-Atlanta GX2 EDFA optical amplifier module
- HFC optical node
Monitoring Examples
No sample objects or module description text were provided for this MIB. Given that it manages an EDFA module, the realistic monitoring value would be polling optical output power and pump-laser temperature/status to catch amplifier degradation before it impacts downstream signal levels to subscribers, but no concrete table or object names can be honestly cited from the data given here.
What Can Be Monitored
- optical output power
- pump laser status/temperature
- amplifier alarm/fault state
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2EDFA | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapEDFAConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.11.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEDFAConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.11.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapEDFAModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.3 | This trap is issued when the EDFA Module's Temperature goes out of range. | ||
| NTF trapEDFAOpticalInPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.4 | This trap is issued when the input Optical Input Power parameter goes out of range. | ||
| NTF trapEDFAOpticalOutPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.5 | This trap is issued when the input Optical Output Power parameter goes out of range. | ||
| NTF trapEDFATECTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.6 | This trap is issued when the EDFA TEC Temperature goes out of range. | ||
| NTF trapEDFATECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.7 | This trap is issued when the EDFA TEC Current goes out of range. | ||
| NTF trapEDFALaserCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.8 | This trap is issued when the EDFA Laser Current goes out of range. | ||
| NTF trapEDFALaserPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.9 | This trap is issued when the EDFA Laser Power goes out of range. | ||
| NTF trapEDFAPlus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.10 | This trap is issued when the EDFA 12 volt current parameter goes out of range. | ||
| NTF trapEDFAPlus37CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.11 | This trap is issued when the EDFA 3.7 volt current parameter goes out of range. | ||
| NTF trapEDFAFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.12 | This trap is issued when the EDFA Module's Fan Currrent parameter goes out of range. | ||
| NTF trapEDFAResetFacDefault | 1.3.6.1.4.1.1166.6.1.2.11.0.13 | This trap is issued when the EDFA resets to factory defaults | ||
| NTF trapEDFAStandbyMode | 1.3.6.1.4.1.1166.6.1.2.11.0.14 | This trap is issued when the EDFA is in Standby Mode. | ||
| NTF trapEDFAOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.11.0.15 | This trap is issued when the EDFA is in Optical Input Shutdown. | ||
| NTF trapEDFATECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.11.0.16 | This trap is issued when the EDFA is in TEC Temperature Shutdown. | ||
| NTF trapEDFAKeySwitch | 1.3.6.1.4.1.1166.6.1.2.11.0.17 | This trap is issued when the Key Switch disables the EDFA. | ||
| NTF trapEDFAPowerFail | 1.3.6.1.4.1.1166.6.1.2.11.0.18 | This trap is issued when there is an EDFA Power Supply Failure. | ||
| NTF trapEDFALasCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.11.0.19 | This trap is issued when the EDFA is in Laser Current Shutdown. | ||
| NTF trapEDFALasPowerShutdown | 1.3.6.1.4.1.1166.6.1.2.11.0.20 | This trap is issued when the EDFA is in Laser Power Shutdown. | ||
| NTF trapEDFAInvalidMode | 1.3.6.1.4.1.1166.6.1.2.11.0.21 | This trap is issued when the EDFA is in an invalid mode. | ||
| NTF trapEDFAFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.22 | This trap is issued when the EDFA Module's boot or flash programming sequence has detected a Flash error. | ||
| NTF trapEDFABoot0Alarm | 1.3.6.1.4.1.1166.6.1.2.11.0.23 | This trap is issued when the EDFA Module's Bank 0 Boot sequence has detected an error. | ||
| NTF trapEDFABoot1Alarm | 1.3.6.1.4.1.1166.6.1.2.11.0.24 | This trap is issued when the EDFA Module's Bank 1 Boot sequence has detected an error. | ||
| NTF trapEDFAAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.25 | This trap is issued when the EDFA Module detects an error calculating the alarm limit CRC. | ||
| NTF trapEDFAFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.26 | This trap is issued when the EDFA Module detects an error calculating the Factory data CRC. | ||
| NTF trapEDFACalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.27 | This trap is issued when the EDFA Module detects an error calculating the Calibration data CRC. | ||
| NTF trapEDFAFacCalFloatAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.28 | This trap is issued when the EDFA Module detects factory calibration float data alarm. | ||
| NTF trapEDFAOptInThreshAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.29 | This trap is issued when the EDFA Module Optical Input drops below the user set threshold. | ||
| NTF trapEDFAGainErrorAlarm | 1.3.6.1.4.1.1166.6.1.2.11.0.30 | This trap is issued when the EDFA Module cannot produce the desired user set gain in Constant Gain Set Mode. | ||
| gx2EDFADescriptor | 1.3.6.1.4.1.1166.6.1.2.11.1 | |||
| gx2EDFAAnalogTable | 1.3.6.1.4.1.1166.6.1.2.11.2 | not-accessible | This table contains gx2EDFA specific parameters with nominal and current values. | |
| gx2EDFAAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.11.2.1 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT edfagx2EDFAAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.11.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR edfalabelModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR edfauomModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO edfamajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.8 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.10 | Float | read-only | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.11 | Float | read-only | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR edfalabelOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Optical Input Power Analog parameter. |
| STR edfauomOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Input Power Analog parameter. |
| FLO edfamajorHighOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.19 | Float | read-only | The value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.21 | Float | read-only | The value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.22 | Float | read-only | The value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateOptInPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Input Power Analog parameter. |
| STR edfalabelOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Optical Output Power Analog parameter. |
| STR edfauomOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter. |
| FLO edfamajorHighOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.30 | Float | read-only | The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.32 | Float | read-only | The value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.33 | Float | read-only | The value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateOptOutPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Output Power Analog parameter. |
| STR edfalabelTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.35 | DisplayString | read-only | The value of this object provides the label of the TEC Temperature Analog parameter. |
| STR edfauomTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter. |
| FLO edfamajorHighTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.41 | Float | read-only | The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.42 | INTEGER | read-only | The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.43 | Float | read-only | The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.44 | Float | read-only | The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateTECTemp | 1.3.6.1.4.1.1166.6.1.2.11.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Temperature Analog parameter. |
| STR edfalabelTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.46 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR edfauomTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter. |
| FLO edfamajorHighTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.52 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.53 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.54 | Float | read-only | The value of this object provides the minimum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.55 | Float | read-only | The value of this object provides the maximum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateTECCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR edfalabelLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Laser Current Analog parameter. |
| STR edfauomLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Current Analog parameter. |
| FLO edfamajorHighLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.63 | Float | read-only | The value of this object provides the Current value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Laser Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.65 | Float | read-only | The value of this object provides the minimum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.66 | Float | read-only | The value of this object provides the maximum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Current Analog parameter. |
| STR edfalabelLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Laser Power Analog parameter. |
| STR edfauomLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Power Analog parameter. |
| FLO edfamajorHighLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.74 | Float | read-only | The value of this object provides the Current value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.76 | Float | read-only | The value of this object provides the minimum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.77 | Float | read-only | The value of this object provides the maximum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateLaserPower | 1.3.6.1.4.1.1166.6.1.2.11.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Power Analog parameter. |
| STR edfalabel12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.79 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR edfauom12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO edfamajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.85 | Float | read-only | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.86 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.87 | Float | read-only | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.88 | Float | read-only | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| STR edfalabel37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.90 | DisplayString | read-only | The value of this object provides the label of the 3.7v Current Analog parameter. |
| STR edfauom37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 3.7v Current Analog parameter. |
| FLO edfamajorHigh37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLow37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHigh37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLow37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValue37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.96 | Float | read-only | The value of this object provides the Current value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlag37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.97 | INTEGER | read-only | The value of this object provides the state of the 3.7v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValue37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.98 | Float | read-only | The value of this object provides the minimum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValue37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.99 | Float | read-only | The value of this object provides the maximum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmState37Volt | 1.3.6.1.4.1.1166.6.1.2.11.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the 3.7v Current Analog parameter. |
| STR edfalabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.101 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR edfauomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO edfamajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.107 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.108 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.109 | Float | read-only | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.110 | Float | read-only | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.11.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR edfalabelOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.112 | DisplayString | read-only | The value of this object provides the label of the Output Power Setting Analog parameter. |
| STR edfauomOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.113 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO edfamajorHighOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.114 | Float | read-only | The value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.115 | Float | read-only | The value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.116 | Float | read-only | The value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.117 | Float | read-only | The value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.118 | Float | read-write | The value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.119 | INTEGER | read-only | The value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.120 | Float | read-only | The value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.121 | Float | read-only | The value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateOPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.122 | INTEGER | read-only | The value of this object provides the curent alarm state of the Output Power Setting Analog parameter. |
| STR edfalabelLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.123 | DisplayString | read-only | The value of this object provides the label of the Laser Power Setting Analog parameter. |
| STR edfauomLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.124 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter. |
| FLO edfamajorHighLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.125 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.126 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.127 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.128 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.129 | Float | read-write | The value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.130 | INTEGER | read-only | The value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.131 | Float | read-only | The value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.132 | Float | read-only | The value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateLPSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.133 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Power Setting Analog parameter. |
| STR edfalabelCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.134 | DisplayString | read-only | The value of this object provides the label of the Constant Gain Setting Analog parameter. |
| STR edfauomCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.135 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter. |
| FLO edfamajorHighCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.136 | Float | read-only | The value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.137 | Float | read-only | The value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.138 | Float | read-only | The value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.139 | Float | read-only | The value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.140 | Float | read-write | The value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.141 | INTEGER | read-only | The value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.142 | Float | read-only | The value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.143 | Float | read-only | The value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateCGSetting | 1.3.6.1.4.1.1166.6.1.2.11.2.1.144 | INTEGER | read-only | The value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter. |
| STR edfalabelOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.145 | DisplayString | read-only | The value of this object provides the label of the Optical Input Threshold Analog parameter. |
| STR edfauomOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.146 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter. |
| FLO edfamajorHighOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.147 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamajorLowOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.148 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorHighOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.149 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfaminorLowOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.150 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfacurrentValueOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.151 | Float | read-write | The value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfastateFlagOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.152 | INTEGER | read-only | The value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO edfaminValueOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.153 | Float | read-only | The value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO edfamaxValueOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.154 | Float | read-only | The value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT edfaalarmStateOptThreshold | 1.3.6.1.4.1.1166.6.1.2.11.2.1.155 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter. |
| gx2EDFADigitalTable | 1.3.6.1.4.1.1166.6.1.2.11.3 | not-accessible | This table contains gx2EDFA specific parameters with nominal and current values. | |
| gx2EDFADigitalEntry | 1.3.6.1.4.1.1166.6.1.2.11.3.2 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT edfagx2EDFADigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.11.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR edfalabelModeSetting | 1.3.6.1.4.1.1166.6.1.2.11.3.2.2 | DisplayString | read-only | The value of this object provides the label of the EDFA's Mode Digital parameter. |
| STR edfaenumModeSetting | 1.3.6.1.4.1.1166.6.1.2.11.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0. |
| INT edfavalueModeSetting | 1.3.6.1.4.1.1166.6.1.2.11.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module. |
| INT edfastateFlagModeSetting | 1.3.6.1.4.1.1166.6.1.2.11.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelModuleState | 1.3.6.1.4.1.1166.6.1.2.11.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Module State Digital parameter. |
| STR edfaenumModuleState | 1.3.6.1.4.1.1166.6.1.2.11.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT edfavalueModuleState | 1.3.6.1.4.1.1166.6.1.2.11.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT edfastateFlagModuleState | 1.3.6.1.4.1.1166.6.1.2.11.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.11.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR edfaenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.11.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT edfavalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.11.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT edfastateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.11.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2EDFAStatusTable | 1.3.6.1.4.1.1166.6.1.2.11.4 | not-accessible | This table contains gx2EDFA specific parameters with nominal and current values. | |
| gx2EDFAStatusEntry | 1.3.6.1.4.1.1166.6.1.2.11.4.3 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT edfagx2EDFAStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.11.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR edfalabelBoot | 1.3.6.1.4.1.1166.6.1.2.11.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT edfavalueBoot | 1.3.6.1.4.1.1166.6.1.2.11.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagBoot | 1.3.6.1.4.1.1166.6.1.2.11.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelFlash | 1.3.6.1.4.1.1166.6.1.2.11.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT edfavalueFlash | 1.3.6.1.4.1.1166.6.1.2.11.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagFlash | 1.3.6.1.4.1.1166.6.1.2.11.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT edfavalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| INT edfavalueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| INT edfavalueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.11.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Optical Input Power Shutdown Status parameter. |
| INT edfavalueOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagOptInShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.20 | DisplayString | read-only | The value of this object provides the label of the TEC Temperature Shutdown Status parameter. |
| INT edfavalueTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagTECTempShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelTECShutOverride | 1.3.6.1.4.1.1166.6.1.2.11.4.3.23 | DisplayString | read-only | The value of this object provides the label of the TEC Shutdown Override Status parameter. |
| INT edfavalueTECShutOverride | 1.3.6.1.4.1.1166.6.1.2.11.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagTECShutOverride | 1.3.6.1.4.1.1166.6.1.2.11.4.3.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelPowerFail | 1.3.6.1.4.1.1166.6.1.2.11.4.3.26 | DisplayString | read-only | The value of this object provides the label of the Power Supply Fail Status parameter. |
| INT edfavaluePowerFail | 1.3.6.1.4.1.1166.6.1.2.11.4.3.27 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagPowerFail | 1.3.6.1.4.1.1166.6.1.2.11.4.3.28 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelKeySwitch | 1.3.6.1.4.1.1166.6.1.2.11.4.3.29 | DisplayString | read-only | The value of this object provides the label of the Key Switch Setting Status parameter. |
| INT edfavalueKeySwitch | 1.3.6.1.4.1.1166.6.1.2.11.4.3.30 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagKeySwitch | 1.3.6.1.4.1.1166.6.1.2.11.4.3.31 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.32 | DisplayString | read-only | The value of this object provides the label of the Laser Current Shutdown Status parameter. |
| INT edfavalueLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.33 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagLaserCurrShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.34 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.35 | DisplayString | read-only | The value of this object provides the label of the Laser Power Shutdown Status parameter. |
| INT edfavalueLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.36 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagLaserPowShutdown | 1.3.6.1.4.1.1166.6.1.2.11.4.3.37 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelADCStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.38 | DisplayString | read-only | The value of this object provides the label of the ADC Operation Status parameter. |
| INT edfavalueADCStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.39 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagADCStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.40 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelConstGainStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.41 | DisplayString | read-only | The value of this object provides the label of the Constant Gain Status parameter. |
| INT edfavalueConstGainStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.42 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagConstGainStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.43 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR edfalabelStandbyStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.44 | DisplayString | read-only | The value of this object provides the label of the Standby Status parameter. |
| INT edfavalueStandbyStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.45 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT edfastateflagStandbyStatus | 1.3.6.1.4.1.1166.6.1.2.11.4.3.46 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2EDFAFactoryTable | 1.3.6.1.4.1.1166.6.1.2.11.5 | not-accessible | This table contains gx2EDFA specific parameters with nominal and current values. | |
| gx2EDFAFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.11.5.4 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT edfagx2EDFAFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.11.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT edfabootControlByte | 1.3.6.1.4.1.1166.6.1.2.11.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT edfabootStatusByte | 1.3.6.1.4.1.1166.6.1.2.11.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT edfabank0CRC | 1.3.6.1.4.1.1166.6.1.2.11.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT edfabank1CRC | 1.3.6.1.4.1.1166.6.1.2.11.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT edfaprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.11.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT edfafactoryCRC | 1.3.6.1.4.1.1166.6.1.2.11.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT edfacalculateCRC | 1.3.6.1.4.1.1166.6.1.2.11.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT edfahourMeter | 1.3.6.1.4.1.1166.6.1.2.11.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT edfaflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.11.5.4.10 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side A. |
| INT edfaflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.11.5.4.11 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side B. |
| STR edfafwRev0 | 1.3.6.1.4.1.1166.6.1.2.11.5.4.12 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 0. |
| STR edfafwRev1 | 1.3.6.1.4.1.1166.6.1.2.11.5.4.13 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 1. |
| gx2EDFAHoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.11.6 | not-accessible | This table contains gx2EDFA specific parameters with nominal and current values. | |
| gx2EDFAHoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.11.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2EDFAHoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.11.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT gx2EDFAHoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.11.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT gx2EDFAHoldTimeData | 1.3.6.1.4.1.1166.6.1.2.11.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Ciena Omni gx2 EDFA (Erbium-Doped Fiber Amplifier) MIB managing optical amplifier status and performance metrics.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.