OMNI-gx2EDFA-MIB :: edfamajorHighOptOutPower

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2EDFA-MIB › edfamajorHighOptOutPower

edfamajorHighOptOutPower

Module: OMNI-gx2EDFA-MIB

OID (symbolic): OMNI-gx2EDFA-MIB::edfamajorHighOptOutPower

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.11.2.1.26

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is edfamajorHighOptOutPower?

Configured Major-High alarm threshold for optical output power. An admin sets this to catch the amplifier launching more optical power downstream than the fiber plant or receivers are rated to tolerate.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.2.1.26
snmpwalk -v2c -c public <target> OMNI-gx2EDFA-MIB::edfamajorHighOptOutPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.2.1.26.1
snmpget -v2c -c public <target> OMNI-gx2EDFA-MIB::edfamajorHighOptOutPower.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> edfamajorHighOptOutPower.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EDFA-MIB::edfamajorHighOptOutPower OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.11gx2EDFAGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.11.2gx2EDFAAnalogTableOMNI-gx2EDFA-MIB
1.3.6.1.4.1.1166.6.1.2.11.2.1gx2EDFAAnalogEntryOMNI-gx2EDFA-MIB
1.3.6.1.4.1.1166.6.1.2.11.2.1.26edfamajorHighOptOutPowerOMNI-gx2EDFA-MIB