All MIBs › OMNI-gx2EDFA-MIB › edfavalueTECTempShutdown
edfavalueTECTempShutdown
Module: OMNI-gx2EDFA-MIB
OID (symbolic): OMNI-gx2EDFA-MIB::edfavalueTECTempShutdown
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.11.4.3.21
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
What is edfavalueTECTempShutdown?
Current severity of the TEC-temperature-shutdown condition, from ok(1) through critical(6). An admin treats a critical reading here as confirmation that a laser outage was caused by the cooling loop failing to protect the laser, rather than a direct laser or power failure.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.4.3.21 snmpwalk -v2c -c public <target> OMNI-gx2EDFA-MIB::edfavalueTECTempShutdown
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.4.3.21.1 snmpget -v2c -c public <target> OMNI-gx2EDFA-MIB::edfavalueTECTempShutdown.1
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EDFA-MIB::edfavalueTECTempShutdown OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11 | gx2EDFA | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.11.4 | gx2EDFAStatusTable | OMNI-gx2EDFA-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11.4.3 | gx2EDFAStatusEntry | OMNI-gx2EDFA-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11.4.3.21 | edfavalueTECTempShutdown | OMNI-gx2EDFA-MIB |