Description: The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
What is edfavalueOptInShutdown?
Current severity of the optical-input-power-shutdown condition, from ok(1) through critical(6), driven by comparison against edfacurrentValueOptThreshold. An admin treats a critical reading here as the explanation for a total loss of amplifier output when the root cause is a lost/degraded upstream optical feed rather than a laser or power-supply fault.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.4.3.18 snmpwalk -v2c -c public <target> OMNI-gx2EDFA-MIB::edfavalueOptInShutdown
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.4.3.18.1 snmpget -v2c -c public <target> OMNI-gx2EDFA-MIB::edfavalueOptInShutdown.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> edfavalueOptInShutdown.1
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EDFA-MIB::edfavalueOptInShutdown OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11 | gx2EDFA | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.11.4 | gx2EDFAStatusTable | OMNI-gx2EDFA-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11.4.3 | gx2EDFAStatusEntry | OMNI-gx2EDFA-MIB |
| 1.3.6.1.4.1.1166.6.1.2.11.4.3.18 | edfavalueOptInShutdown | OMNI-gx2EDFA-MIB |