OMNI-gx2EDFA-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2EDFA FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "1" Jan 20, 2003 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR Forward Path Receiver Module MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2EDFA Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2EDFA device type. -- These parameters are common across all network elements -- from gx2EDFA device type. -- -- The gx2EDFA Network Elements subgroup is -- a list of gx2EDFA type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2EDFATableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2EDFA type. -- -- Both groups are mandatory for management of gx2EDFA devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2EDFA Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2EDFA device type. -- These parameters are common across all network elements -- from gx2EDFA device type. gx2EDFADescriptor OBJECT IDENTIFIER ::= {gx2EDFA 1} --***************************************************************************** -- gx2EDFA Table -- Contains a list of all gx2EDFA type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2EDFATableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2EDFA type. gx2EDFAAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2EDFAAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2EDFA specific parameters with nominal and current values." ::= { gx2EDFA 2 } gx2EDFAAnalogEntry OBJECT-TYPE SYNTAX Gx2EDFAAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { edfagx2EDFAAnalogTableIndex } ::= { gx2EDFAAnalogTable 1} --************************************************************************* gx2EDFADigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2EDFADigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2EDFA specific parameters with nominal and current values." ::= { gx2EDFA 3 } gx2EDFADigitalEntry OBJECT-TYPE SYNTAX Gx2EDFADigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { edfagx2EDFADigitalTableIndex } ::= { gx2EDFADigitalTable 2} --************************************************************************* gx2EDFAStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2EDFAStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2EDFA specific parameters with nominal and current values." ::= { gx2EDFA 4 } gx2EDFAStatusEntry OBJECT-TYPE SYNTAX Gx2EDFAStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { edfagx2EDFAStatusTableIndex } ::= { gx2EDFAStatusTable 3} --************************************************************************* gx2EDFAFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2EDFAFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2EDFA specific parameters with nominal and current values." ::= { gx2EDFA 5 } gx2EDFAFactoryEntry OBJECT-TYPE SYNTAX Gx2EDFAFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { edfagx2EDFAFactoryTableIndex } ::= { gx2EDFAFactoryTable 4} --************************************************************************* -- // Section: Table definitions - Hold Time gx2EDFAHoldTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2EDFAHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2EDFA specific parameters with nominal and current values." ::= { gx2EDFA 6 } gx2EDFAHoldTimeEntry OBJECT-TYPE SYNTAX Gx2EDFAHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2EDFAHoldTimeTableIndex, gx2EDFAHoldTimeSpecIndex } ::= { gx2EDFAHoldTimeTable 5} Gx2EDFAAnalogEntry ::= SEQUENCE { edfagx2EDFAAnalogTableIndex INTEGER, -- Analog Parameters edfalabelModTemp DisplayString (SIZE (0..80)), edfauomModTemp DisplayString (SIZE (0..80)), edfamajorHighModTemp Float, edfamajorLowModTemp Float, edfaminorHighModTemp Float, edfaminorLowModTemp Float, edfacurrentValueModTemp Float, edfastateFlagModTemp INTEGER, edfaminValueModTemp Float, edfamaxValueModTemp Float, edfaalarmStateModTemp INTEGER, edfalabelOptInPower DisplayString (SIZE (0..80)), edfauomOptInPower DisplayString (SIZE (0..80)), edfamajorHighOptInPower Float, edfamajorLowOptInPower Float, edfaminorHighOptInPower Float, edfaminorLowOptInPower Float, edfacurrentValueOptInPower Float, edfastateFlagOptInPower INTEGER, edfaminValueOptInPower Float, edfamaxValueOptInPower Float, edfaalarmStateOptInPower INTEGER, edfalabelOptOutPower DisplayString (SIZE (0..80)), edfauomOptOutPower DisplayString (SIZE (0..80)), edfamajorHighOptOutPower Float, edfamajorLowOptOutPower Float, edfaminorHighOptOutPower Float, edfaminorLowOptOutPower Float, edfacurrentValueOptOutPower Float, edfastateFlagOptOutPower INTEGER, edfaminValueOptOutPower Float, edfamaxValueOptOutPower Float, edfaalarmStateOptOutPower INTEGER, edfalabelTECTemp DisplayString (SIZE (0..80)), edfauomTECTemp DisplayString (SIZE (0..80)), edfamajorHighTECTemp Float, edfamajorLowTECTemp Float, edfaminorHighTECTemp Float, edfaminorLowTECTemp Float, edfacurrentValueTECTemp Float, edfastateFlagTECTemp INTEGER, edfaminValueTECTemp Float, edfamaxValueTECTemp Float, edfaalarmStateTECTemp INTEGER, edfalabelTECCurrent DisplayString (SIZE (0..80)), edfauomTECCurrent DisplayString (SIZE (0..80)), edfamajorHighTECCurrent Float, edfamajorLowTECCurrent Float, edfaminorHighTECCurrent Float, edfaminorLowTECCurrent Float, edfacurrentValueTECCurrent Float, edfastateFlagTECCurrent INTEGER, edfaminValueTECCurrent Float, edfamaxValueTECCurrent Float, edfaalarmStateTECCurrent INTEGER, edfalabelLaserCurrent DisplayString (SIZE (0..80)), edfauomLaserCurrent DisplayString (SIZE (0..80)), edfamajorHighLaserCurrent Float, edfamajorLowLaserCurrent Float, edfaminorHighLaserCurrent Float, edfaminorLowLaserCurrent Float, edfacurrentValueLaserCurrent Float, edfastateFlagLaserCurrent INTEGER, edfaminValueLaserCurrent Float, edfamaxValueLaserCurrent Float, edfaalarmStateLaserCurrent INTEGER, edfalabelLaserPower DisplayString (SIZE (0..80)), edfauomLaserPower DisplayString (SIZE (0..80)), edfamajorHighLaserPower Float, edfamajorLowLaserPower Float, edfaminorHighLaserPower Float, edfaminorLowLaserPower Float, edfacurrentValueLaserPower Float, edfastateFlagLaserPower INTEGER, edfaminValueLaserPower Float, edfamaxValueLaserPower Float, edfaalarmStateLaserPower INTEGER, edfalabel12Volt DisplayString (SIZE (0..80)), edfauom12Volt DisplayString (SIZE (0..80)), edfamajorHigh12Volt Float, edfamajorLow12Volt Float, edfaminorHigh12Volt Float, edfaminorLow12Volt Float, edfacurrentValue12Volt Float, edfastateFlag12Volt INTEGER, edfaminValue12Volt Float, edfamaxValue12Volt Float, edfaalarmState12Volt INTEGER, edfalabel37Volt DisplayString (SIZE (0..80)), edfauom37Volt DisplayString (SIZE (0..80)), edfamajorHigh37Volt Float, edfamajorLow37Volt Float, edfaminorHigh37Volt Float, edfaminorLow37Volt Float, edfacurrentValue37Volt Float, edfastateFlag37Volt INTEGER, edfaminValue37Volt Float, edfamaxValue37Volt Float, edfaalarmState37Volt INTEGER, edfalabelFanCurrent DisplayString (SIZE (0..80)), edfauomFanCurrent DisplayString (SIZE (0..80)), edfamajorHighFanCurrent Float, edfamajorLowFanCurrent Float, edfaminorHighFanCurrent Float, edfaminorLowFanCurrent Float, edfacurrentValueFanCurrent Float, edfastateFlagFanCurrent INTEGER, edfaminValueFanCurrent Float, edfamaxValueFanCurrent Float, edfaalarmStateFanCurrent INTEGER, edfalabelOPSetting DisplayString (SIZE (0..80)), edfauomOPSetting DisplayString (SIZE (0..80)), edfamajorHighOPSetting Float, edfamajorLowOPSetting Float, edfaminorHighOPSetting Float, edfaminorLowOPSetting Float, edfacurrentValueOPSetting Float, edfastateFlagOPSetting INTEGER, edfaminValueOPSetting Float, edfamaxValueOPSetting Float, edfaalarmStateOPSetting INTEGER, edfalabelLPSetting DisplayString (SIZE (0..80)), edfauomLPSetting DisplayString (SIZE (0..80)), edfamajorHighLPSetting Float, edfamajorLowLPSetting Float, edfaminorHighLPSetting Float, edfaminorLowLPSetting Float, edfacurrentValueLPSetting Float, edfastateFlagLPSetting INTEGER, edfaminValueLPSetting Float, edfamaxValueLPSetting Float, edfaalarmStateLPSetting INTEGER, edfalabelCGSetting DisplayString (SIZE (0..80)), edfauomCGSetting DisplayString (SIZE (0..80)), edfamajorHighCGSetting Float, edfamajorLowCGSetting Float, edfaminorHighCGSetting Float, edfaminorLowCGSetting Float, edfacurrentValueCGSetting Float, edfastateFlagCGSetting INTEGER, edfaminValueCGSetting Float, edfamaxValueCGSetting Float, edfaalarmStateCGSetting INTEGER, edfalabelOptThreshold DisplayString (SIZE (0..80)), edfauomOptThreshold DisplayString (SIZE (0..80)), edfamajorHighOptThreshold Float, edfamajorLowOptThreshold Float, edfaminorHighOptThreshold Float, edfaminorLowOptThreshold Float, edfacurrentValueOptThreshold Float, edfastateFlagOptThreshold INTEGER, edfaminValueOptThreshold Float, edfamaxValueOptThreshold Float, edfaalarmStateOptThreshold INTEGER } -- **************** Digital Parameters *********************** Gx2EDFADigitalEntry ::= SEQUENCE { edfagx2EDFADigitalTableIndex INTEGER, edfalabelModeSetting DisplayString (SIZE (0..80)), edfavalueModeSetting INTEGER, edfaenumModeSetting DisplayString (SIZE (0..80)), edfastateFlagModeSetting INTEGER, edfalabelModuleState DisplayString (SIZE (0..80)), edfavalueModuleState INTEGER, edfaenumModuleState DisplayString (SIZE (0..80)), edfastateFlagModuleState INTEGER, edfalabelFactoryDefault DisplayString (SIZE (0..80)), edfavalueFactoryDefault INTEGER, edfaenumFactoryDefault DisplayString (SIZE (0..80)), edfastateFlagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2EDFAStatusEntry ::= SEQUENCE { edfagx2EDFAStatusTableIndex INTEGER, edfalabelBoot DisplayString (SIZE (0..80)), edfavalueBoot INTEGER, edfastateflagBoot INTEGER, edfalabelFlash DisplayString (SIZE (0..80)), edfavalueFlash INTEGER, edfastateflagFlash INTEGER, edfalabelFactoryDataCRC DisplayString (SIZE (0..80)), edfavalueFactoryDataCRC INTEGER, edfastateflagFactoryDataCRC INTEGER, edfalabelAlarmDataCRC DisplayString (SIZE (0..80)), edfavalueAlarmDataCRC INTEGER, edfastateflagAlarmDataCRC INTEGER, edfalabelCalibrationDataCRC DisplayString (SIZE (0..80)), edfavalueCalibrationDataCRC INTEGER, edfastateflagCalibrationDataCRC INTEGER, edfalabelOptInShutdown DisplayString (SIZE (0..80)), edfavalueOptInShutdown INTEGER, edfastateflagOptInShutdown INTEGER, edfalabelTECTempShutdown DisplayString (SIZE (0..80)), edfavalueTECTempShutdown INTEGER, edfastateflagTECTempShutdown INTEGER, edfalabelTECShutOverride DisplayString (SIZE (0..80)), edfavalueTECShutOverride INTEGER, edfastateflagTECShutOverride INTEGER, edfalabelPowerFail DisplayString (SIZE (0..80)), edfavaluePowerFail INTEGER, edfastateflagPowerFail INTEGER, edfalabelKeySwitch DisplayString (SIZE (0..80)), edfavalueKeySwitch INTEGER, edfastateflagKeySwitch INTEGER, edfalabelLaserCurrShutdown DisplayString (SIZE (0..80)), edfavalueLaserCurrShutdown INTEGER, edfastateflagLaserCurrShutdown INTEGER, edfalabelLaserPowShutdown DisplayString (SIZE (0..80)), edfavalueLaserPowShutdown INTEGER, edfastateflagLaserPowShutdown INTEGER, edfalabelADCStatus DisplayString (SIZE (0..80)), edfavalueADCStatus INTEGER, edfastateflagADCStatus INTEGER, edfalabelConstGainStatus DisplayString (SIZE (0..80)), edfavalueConstGainStatus INTEGER, edfastateflagConstGainStatus INTEGER, edfalabelStandbyStatus DisplayString (SIZE (0..80)), edfavalueStandbyStatus INTEGER, edfastateflagStandbyStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2EDFAFactoryEntry ::= SEQUENCE { edfagx2EDFAFactoryTableIndex INTEGER, edfabootControlByte INTEGER, edfabootStatusByte INTEGER, edfabank0CRC INTEGER, edfabank1CRC INTEGER, edfaprgEEPROMByte INTEGER, edfafactoryCRC INTEGER, edfacalculateCRC INTEGER, edfahourMeter INTEGER, edfaflashPrgCntA INTEGER, edfaflashPrgCntB INTEGER, edfafwRev0 DisplayString (SIZE (0..80)), edfafwRev1 DisplayString (SIZE (0..80)) } -- **************** Hold Time Parameters ************************************* Gx2EDFAHoldTimeEntry ::= SEQUENCE { gx2EDFAHoldTimeTableIndex INTEGER, gx2EDFAHoldTimeSpecIndex INTEGER, gx2EDFAHoldTimeData INTEGER } -- ************** Analog Parameters **************************** edfagx2EDFAAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2EDFAAnalogEntry 1} -- New Parameter edfalabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2EDFAAnalogEntry 2} edfauomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2EDFAAnalogEntry 3} edfamajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 4} edfamajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 5} edfaminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 6} edfaminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 7} edfacurrentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 8} edfastateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 9} edfaminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 10} edfamaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 11} edfaalarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2EDFAAnalogEntry 12} -- New Parameter edfalabelOptInPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Input Power Analog parameter." ::= { gx2EDFAAnalogEntry 13} edfauomOptInPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Input Power Analog parameter." ::= { gx2EDFAAnalogEntry 14} edfamajorHighOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 15} edfamajorLowOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 16} edfaminorHighOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 17} edfaminorLowOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 18} edfacurrentValueOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 19} edfastateFlagOptInPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 20} edfaminValueOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 21} edfamaxValueOptInPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 22} edfaalarmStateOptInPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Input Power Analog parameter." ::= { gx2EDFAAnalogEntry 23} -- New Parameter edfalabelOptOutPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Power Analog parameter." ::= { gx2EDFAAnalogEntry 24} edfauomOptOutPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter." ::= { gx2EDFAAnalogEntry 25} edfamajorHighOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 26} edfamajorLowOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 27} edfaminorHighOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 28} edfaminorLowOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 29} edfacurrentValueOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 30} edfastateFlagOptOutPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 31} edfaminValueOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 32} edfamaxValueOptOutPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 33} edfaalarmStateOptOutPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Output Power Analog parameter." ::= { gx2EDFAAnalogEntry 34} -- New Parameter edfalabelTECTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Temperature Analog parameter." ::= { gx2EDFAAnalogEntry 35} edfauomTECTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter." ::= { gx2EDFAAnalogEntry 36} edfamajorHighTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 37} edfamajorLowTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 38} edfaminorHighTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 39} edfaminorLowTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 40} edfacurrentValueTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 41} edfastateFlagTECTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 42} edfaminValueTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 43} edfamaxValueTECTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 44} edfaalarmStateTECTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Temperature Analog parameter." ::= { gx2EDFAAnalogEntry 45} -- New Parameter edfalabelTECCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2EDFAAnalogEntry 46} edfauomTECCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter." ::= { gx2EDFAAnalogEntry 47} edfamajorHighTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 48} edfamajorLowTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 49} edfaminorHighTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 50} edfaminorLowTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 51} edfacurrentValueTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 52} edfastateFlagTECCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 53} edfaminValueTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 54} edfamaxValueTECCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 55} edfaalarmStateTECCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2EDFAAnalogEntry 56} -- New Parameter edfalabelLaserCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Current Analog parameter." ::= { gx2EDFAAnalogEntry 57} edfauomLaserCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Current Analog parameter." ::= { gx2EDFAAnalogEntry 58} edfamajorHighLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 59} edfamajorLowLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 60} edfaminorHighLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 61} edfaminorLowLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 62} edfacurrentValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 63} edfastateFlagLaserCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 64} edfaminValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 65} edfamaxValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 66} edfaalarmStateLaserCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Current Analog parameter." ::= { gx2EDFAAnalogEntry 67} -- New Parameter edfalabelLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Power Analog parameter." ::= { gx2EDFAAnalogEntry 68} edfauomLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Power Analog parameter." ::= { gx2EDFAAnalogEntry 69} edfamajorHighLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 70} edfamajorLowLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 71} edfaminorHighLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 72} edfaminorLowLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 73} edfacurrentValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 74} edfastateFlagLaserPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 75} edfaminValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 76} edfamaxValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 77} edfaalarmStateLaserPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Power Analog parameter." ::= { gx2EDFAAnalogEntry 78} -- New Parameter edfalabel12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2EDFAAnalogEntry 79} edfauom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2EDFAAnalogEntry 80} edfamajorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 81} edfamajorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 82} edfaminorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 83} edfaminorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 84} edfacurrentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 85} edfastateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 86} edfaminValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 87} edfamaxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 88} edfaalarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2EDFAAnalogEntry 89} -- New Parameter edfalabel37Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 3.7v Current Analog parameter." ::= { gx2EDFAAnalogEntry 90} edfauom37Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 3.7v Current Analog parameter." ::= { gx2EDFAAnalogEntry 91} edfamajorHigh37Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 92} edfamajorLow37Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 93} edfaminorHigh37Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 94} edfaminorLow37Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 95} edfacurrentValue37Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 96} edfastateFlag37Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 3.7v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 97} edfaminValue37Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 98} edfamaxValue37Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 99} edfaalarmState37Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 3.7v Current Analog parameter." ::= { gx2EDFAAnalogEntry 100} -- New Parameter edfalabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2EDFAAnalogEntry 101} edfauomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2EDFAAnalogEntry 102} edfamajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 103} edfamajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 104} edfaminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 105} edfaminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 106} edfacurrentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 107} edfastateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 108} edfaminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 109} edfamaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 110} edfaalarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2EDFAAnalogEntry 111} -- New Parameter edfalabelOPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Output Power Setting Analog parameter." ::= { gx2EDFAAnalogEntry 112} edfauomOPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2EDFAAnalogEntry 113} edfamajorHighOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 114} edfamajorLowOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 115} edfaminorHighOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 116} edfaminorLowOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 117} edfacurrentValueOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 118} edfastateFlagOPSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 119} edfaminValueOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 120} edfamaxValueOPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 121} edfaalarmStateOPSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Output Power Setting Analog parameter." ::= { gx2EDFAAnalogEntry 122} -- New Parameter edfalabelLPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Power Setting Analog parameter." ::= { gx2EDFAAnalogEntry 123} edfauomLPSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter." ::= { gx2EDFAAnalogEntry 124} edfamajorHighLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 125} edfamajorLowLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 126} edfaminorHighLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 127} edfaminorLowLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 128} edfacurrentValueLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 129} edfastateFlagLPSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 130} edfaminValueLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 131} edfamaxValueLPSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 132} edfaalarmStateLPSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Power Setting Analog parameter." ::= { gx2EDFAAnalogEntry 133} -- New Parameter edfalabelCGSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Constant Gain Setting Analog parameter." ::= { gx2EDFAAnalogEntry 134} edfauomCGSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter." ::= { gx2EDFAAnalogEntry 135} edfamajorHighCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 136} edfamajorLowCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 137} edfaminorHighCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 138} edfaminorLowCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 139} edfacurrentValueCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 140} edfastateFlagCGSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 141} edfaminValueCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 142} edfamaxValueCGSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 143} edfaalarmStateCGSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter." ::= { gx2EDFAAnalogEntry 144} -- New Parameter edfalabelOptThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Input Threshold Analog parameter." ::= { gx2EDFAAnalogEntry 145} edfauomOptThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter." ::= { gx2EDFAAnalogEntry 146} edfamajorHighOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 147} edfamajorLowOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 148} edfaminorHighOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 149} edfaminorLowOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 150} edfacurrentValueOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 151} edfastateFlagOptThreshold OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAAnalogEntry 152} edfaminValueOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 153} edfamaxValueOptThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2EDFAAnalogEntry 154} edfaalarmStateOptThreshold OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter." ::= { gx2EDFAAnalogEntry 155} -- ************************ Digital parameters ********************************** edfagx2EDFADigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2EDFADigitalEntry 1} -- New parameter edfalabelModeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the EDFA's Mode Digital parameter." ::= { gx2EDFADigitalEntry 2} edfaenumModeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0." ::= { gx2EDFADigitalEntry 3} edfavalueModeSetting OBJECT-TYPE SYNTAX INTEGER { power-out-preset(1), power-out-set(2), laser-power-preset(3), laser-power-set(4), constant-gain-preset(5), constant-gain-set(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module." ::= { gx2EDFADigitalEntry 4} edfastateFlagModeSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFADigitalEntry 5} -- New parameter edfalabelModuleState OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module State Digital parameter." ::= { gx2EDFADigitalEntry 6} edfaenumModuleState OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2EDFADigitalEntry 7} edfavalueModuleState OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2EDFADigitalEntry 8} edfastateFlagModuleState OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFADigitalEntry 9} -- New parameter edfalabelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2EDFADigitalEntry 10} edfaenumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2EDFADigitalEntry 11} edfavalueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2EDFADigitalEntry 12} edfastateFlagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFADigitalEntry 13} --*********** STATUS ***************** edfagx2EDFAStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2EDFAStatusEntry 1} --New Parameter edfalabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2EDFAStatusEntry 2} edfavalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 3} edfastateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 4} --New Parameter edfalabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2EDFAStatusEntry 5} edfavalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 6} edfastateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 7} --New Parameter edfalabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2EDFAStatusEntry 8} edfavalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 9} edfastateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 10} --New Parameter edfalabelAlarmDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data CRC Status parameter." ::= { gx2EDFAStatusEntry 11} edfavalueAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 12} edfastateflagAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 13} --New Parameter edfalabelCalibrationDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Calibration Data CRC Status parameter." ::= { gx2EDFAStatusEntry 14} edfavalueCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 15} edfastateflagCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 16} --New Parameter edfalabelOptInShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Input Power Shutdown Status parameter." ::= { gx2EDFAStatusEntry 17} edfavalueOptInShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 18} edfastateflagOptInShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 19} --New Parameter edfalabelTECTempShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Temperature Shutdown Status parameter." ::= { gx2EDFAStatusEntry 20} edfavalueTECTempShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 21} edfastateflagTECTempShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 22} --New Parameter edfalabelTECShutOverride OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Shutdown Override Status parameter." ::= { gx2EDFAStatusEntry 23} edfavalueTECShutOverride OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 24} edfastateflagTECShutOverride OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 25} --New Parameter edfalabelPowerFail OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Power Supply Fail Status parameter." ::= { gx2EDFAStatusEntry 26} edfavaluePowerFail OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 27} edfastateflagPowerFail OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 28} --New Parameter edfalabelKeySwitch OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Key Switch Setting Status parameter." ::= { gx2EDFAStatusEntry 29} edfavalueKeySwitch OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 30} edfastateflagKeySwitch OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 31} --New Parameter edfalabelLaserCurrShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Current Shutdown Status parameter." ::= { gx2EDFAStatusEntry 32} edfavalueLaserCurrShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 33} edfastateflagLaserCurrShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 34} --New Parameter edfalabelLaserPowShutdown OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Power Shutdown Status parameter." ::= { gx2EDFAStatusEntry 35} edfavalueLaserPowShutdown OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 36} edfastateflagLaserPowShutdown OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 37} --New Parameter edfalabelADCStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the ADC Operation Status parameter." ::= { gx2EDFAStatusEntry 38} edfavalueADCStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 39} edfastateflagADCStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 40} --New Parameter edfalabelConstGainStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Constant Gain Status parameter." ::= { gx2EDFAStatusEntry 41} edfavalueConstGainStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 42} edfastateflagConstGainStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 43} --New Parameter edfalabelStandbyStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Standby Status parameter." ::= { gx2EDFAStatusEntry 44} edfavalueStandbyStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2EDFAStatusEntry 45} edfastateflagStandbyStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2EDFAStatusEntry 46} -- ************ FACTORY DATA **************** edfagx2EDFAFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2EDFAFactoryEntry 1} edfabootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2EDFAFactoryEntry 2} edfabootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2EDFAFactoryEntry 3} edfabank0CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2EDFAFactoryEntry 4} edfabank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2EDFAFactoryEntry 5} edfaprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2EDFAFactoryEntry 6} edfafactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2EDFAFactoryEntry 7} edfacalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), calibration(2), alarmdata(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2EDFAFactoryEntry 8} edfahourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2EDFAFactoryEntry 9} edfaflashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side A." ::= { gx2EDFAFactoryEntry 10} edfaflashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side B." ::= { gx2EDFAFactoryEntry 11} edfafwRev0 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 0." ::= { gx2EDFAFactoryEntry 12} edfafwRev1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 1." ::= { gx2EDFAFactoryEntry 13} -- *************************Hold Timer Details *************************************** gx2EDFAHoldTimeTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the index of the data object." ::= { gx2EDFAHoldTimeEntry 1} gx2EDFAHoldTimeSpecIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the index of the alarm object to be modified." ::= { gx2EDFAHoldTimeEntry 2} gx2EDFAHoldTimeData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds." ::= { gx2EDFAHoldTimeEntry 3} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- EDFA Module traps -- ************************************************************************** trapEDFAConfigChangeInteger TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapEDFAConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapEDFAModuleTemperatureAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module's Temperature goes out of range." ::= 3 trapEDFAOpticalInPowerAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the input Optical Input Power parameter goes out of range." ::= 4 trapEDFAOpticalOutPowerAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the input Optical Output Power parameter goes out of range." ::= 5 trapEDFATECTemperatureAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA TEC Temperature goes out of range." ::= 6 trapEDFATECCurrentAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA TEC Current goes out of range." ::= 7 trapEDFALaserCurrentAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Laser Current goes out of range." ::= 8 trapEDFALaserPowerAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Laser Power goes out of range." ::= 9 trapEDFAPlus12CurrentAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA 12 volt current parameter goes out of range." ::= 10 trapEDFAPlus37CurrentAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA 3.7 volt current parameter goes out of range." ::= 11 trapEDFAFanCurrentAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module's Fan Currrent parameter goes out of range." ::= 12 trapEDFAResetFacDefault TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA resets to factory defaults" ::= 13 trapEDFAStandbyMode TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA is in Standby Mode." ::= 14 trapEDFAOptInShutdown TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA is in Optical Input Shutdown." ::= 15 trapEDFATECTempShutdown TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA is in TEC Temperature Shutdown." ::= 16 trapEDFAKeySwitch TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Key Switch disables the EDFA." ::= 17 trapEDFAPowerFail TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when there is an EDFA Power Supply Failure." ::= 18 trapEDFALasCurrShutdown TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA is in Laser Current Shutdown." ::= 19 trapEDFALasPowerShutdown TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA is in Laser Power Shutdown." ::= 20 trapEDFAInvalidMode TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA is in an invalid mode." ::= 21 trapEDFAFlashAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module's boot or flash programming sequence has detected a Flash error." ::= 22 trapEDFABoot0Alarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module's Bank 0 Boot sequence has detected an error." ::= 23 trapEDFABoot1Alarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module's Bank 1 Boot sequence has detected an error." ::= 24 trapEDFAAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module detects an error calculating the alarm limit CRC." ::= 25 trapEDFAFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module detects an error calculating the Factory data CRC." ::= 26 trapEDFACalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module detects an error calculating the Calibration data CRC." ::= 27 trapEDFAFacCalFloatAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module detects factory calibration float data alarm." ::= 28 trapEDFAOptInThreshAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module Optical Input drops below the user set threshold." ::= 29 trapEDFAGainErrorAlarm TRAP-TYPE ENTERPRISE gx2EDFA VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the EDFA Module cannot produce the desired user set gain in Constant Gain Set Mode." ::= 30 END