OMNI-gx2EDFA-MIB :: edfacurrentValueTECCurrent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2EDFA-MIB › edfacurrentValueTECCurrent

edfacurrentValueTECCurrent

Module: OMNI-gx2EDFA-MIB

OID (symbolic): OMNI-gx2EDFA-MIB::edfacurrentValueTECCurrent

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.11.2.1.52

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is edfacurrentValueTECCurrent?

Live reading of the current being drawn by the thermoelectric cooler. An admin watches this trend upward over months as an indicator of a cooling assembly nearing end of life, even while the temperature itself still looks fine.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.2.1.52
snmpwalk -v2c -c public <target> OMNI-gx2EDFA-MIB::edfacurrentValueTECCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.2.1.52.1
snmpget -v2c -c public <target> OMNI-gx2EDFA-MIB::edfacurrentValueTECCurrent.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EDFA-MIB::edfacurrentValueTECCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.11gx2EDFAGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.11.2gx2EDFAAnalogTableOMNI-gx2EDFA-MIB
1.3.6.1.4.1.1166.6.1.2.11.2.1gx2EDFAAnalogEntryOMNI-gx2EDFA-MIB
1.3.6.1.4.1.1166.6.1.2.11.2.1.52edfacurrentValueTECCurrentOMNI-gx2EDFA-MIB