OMNI-gx2EDFA-MIB :: gx2EDFAHoldTimeData

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2EDFA-MIB › gx2EDFAHoldTimeData

gx2EDFAHoldTimeData

Module: OMNI-gx2EDFA-MIB

OID (symbolic): OMNI-gx2EDFA-MIB::gx2EDFAHoldTimeData

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.11.6.5.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.

What is gx2EDFAHoldTimeData?

Read-write hold-time value, 0-1300 seconds, used to suppress noise/chatter on analog alarm objects before a transient threshold crossing is actually reported; per the description this is a 32-bit object with validation data in its low bytes and the actual hold time in bytes three/four. An admin raises this on an alarm point that's prone to brief, self-clearing threshold crossings (e.g. a temperature reading that flickers across a minor threshold) so only a sustained violation actually raises a reported alarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.6.5.3
snmpwalk -v2c -c public <target> OMNI-gx2EDFA-MIB::gx2EDFAHoldTimeData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.11.6.5.3.1
snmpget -v2c -c public <target> OMNI-gx2EDFA-MIB::gx2EDFAHoldTimeData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.11.6.5.3.1 i <value>

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EDFA-MIB::gx2EDFAHoldTimeData OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EDFA optical amplifier module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.11gx2EDFAGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.11.6gx2EDFAHoldTimeTableOMNI-gx2EDFA-MIB
1.3.6.1.4.1.1166.6.1.2.11.6.5gx2EDFAHoldTimeEntryOMNI-gx2EDFA-MIB
1.3.6.1.4.1.1166.6.1.2.11.6.5.3gx2EDFAHoldTimeDataOMNI-gx2EDFA-MIB